Validation of an Anti-Müllerian Hormone Cutoff for Polycystic Ovarian Morphology in the Diagnosis of Polycystic Ovary Syndrome in the HARMONIA Study: Protocol for a Prospective, Noninterventional Study

被引:2
作者
Piltonen, Terhi [1 ,2 ,5 ]
Allegranza, Deirdre [3 ]
Hund, Martin [3 ]
Buck, Katharina [4 ]
Sillman, Johanna [3 ]
Arffman, Riikka K. [1 ,2 ]
机构
[1] Univ Oulu, Oulu Univ Hosp, Dept Obstet & Gynecol, MRC Oulu, Oulu, Finland
[2] Univ Oulu, Oulu Univ Hosp, Med Res Ctr, Res Unit Clin Med,MRC Oulu, Oulu, Finland
[3] Roche Diagnost Int Ltd, Rotkreuz, Switzerland
[4] Roche Diagnost GmbH, Penzberg, Germany
[5] Univ Oulu, Oulu Univ Hosp, Dept Obstet & Gynecol, MRC Oulu, Pentti Kaiteran Katu 1, Oulu 90220, Finland
来源
JMIR RESEARCH PROTOCOLS | 2024年 / 13卷
基金
芬兰科学院;
关键词
anti-Mullerian hormone; immunoassay; polycystic ovarian morphology; polycystic ovary syndrome; transvaginal ultrasound; ANTI-MULLERIAN HORMONE; FOLLICLE COUNT; WOMEN; INTEROBSERVER; ULTRASOUND; PCOS; INTRAOBSERVER; VARIABILITY; CRITERIA; AGE;
D O I
10.2196/48854
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Background: Polycystic ovary syndrome (PCOS) is one of the most common endocrine disorders in women and is diagnosed using the Rotterdam criteria, including diagnosis of polycystic ovarian morphology (PCOM) by transvaginal ultrasound (TVUS). Due to high cost, availability, and the impact of the operator and ultrasound equipment on the reliability of the antral follicle count (AFC) by TVUS, an unmet need exists for a diagnostic test to determine PCOM without TVUS. A strong positive correlation between elevated anti-Mullerian hormone (AMH) levels and AFCs has been demonstrated in women with PCOS. In addition, recent updates to the international evidence-based PCOS guidelines state that serum AMH can be used as an alternative to TVUS-determined AFC, in the diagnosis of PCOM. The retrospective APHRODITE study derived and validated an AMH cutoff of 3.2 ng/mL for the Elecsys AMH Plus or Elecsys AMH assays (Roche) to diagnose PCOM in patients with PCOS. Objective: This study aims to further validate, in an independent prospective cohort, the AMH cutoff (3.2 ng/mL) for PCOM determination, which was previously derived and validated in the APHRODITE study. Methods: This large, prospective, multicenter, population-based, noninterventional study will evaluate the previously established AMH cutoff for the determination of PCOM during the diagnosis of PCOS using the Elecsys AMH Plus immunoassay in an independent population. Participants were women born between July 1985 and December 1987 in Northern Finland; the study partially links to the Northern Finland Birth Cohort 1986. We assessed the enrolled women, determined with the 2023 PCOS Guidelines, for current PCOS status and divided them by phenotype if positive. Each participant had 1 study visit to collect serum samples, record clinical data, and undergo a gynecological examination including TVUS. All data were collected by highly trained midwives or trained gynecologists. Sensitivity, specificity, and agreement measures were used to validate the previously determined cutoff in the whole population and in subpopulations based on phenotype and relevant demographic or clinical factors. The minimum target sample size was approximately 1800 women, including approximately 10% with PCOS. Results: At the time of manuscript submission, participant recruitment had concluded, and 1803 women were enrolled into the all women who were taking oral contraceptives were excluded from the primary analysis population. Selection bias was limited as this was a population-based study and participants were not seeking treatment for PCOS symptoms. Validating the AMH cutoff in a large, population-based study will provide further evidence on the utility of the Elecsys AMH Plus or Elecsys AMH assays in PCOM diagnosis as an alternative to TVUS. Measuring AMH for PCOM diagnosis could reduce delayed or missed diagnoses due to operator-dependent TVUS examinations.
引用
收藏
页数:9
相关论文
共 39 条
  • [1] An evaluation of the inter-observer and intra-observer variability of the ultrasound diagnosis of polycystic ovaries
    Amer, SAKS
    Li, TC
    Bygrave, C
    Sprigg, A
    Saravelos, H
    Cooke, ID
    [J]. HUMAN REPRODUCTION, 2002, 17 (06) : 1616 - 1622
  • [2] Updated meta-analysis on the diagnostic accuracy of serum anti-Mullerian hormone in poly cystic ovary syndrome involving 13 509 subjects
    Anand, Shikha
    Kumar, Amit
    Prasad, Anupa
    Trivedi, Kiran
    [J]. JOURNAL OF OBSTETRICS AND GYNAECOLOGY RESEARCH, 2022, 48 (08) : 2162 - 2174
  • [3] [Anonymous], Women's health study (WENDY)-a protocol of a population-based study assessing gynecological and metabolic health in women
  • [4] [Anonymous], 2021, Method sheet: elecsys AMH plus
  • [5] Managing anovulatory infertility and polycystic ovary syndrome
    Balen, Adam H.
    Rutherford, Anthony J.
    [J]. BMJ-BRITISH MEDICAL JOURNAL, 2007, 335 (7621): : 663 - 666
  • [6] Substituting serum anti-Mullerian hormone for polycystic ovary morphology increases the number of women diagnosed with polycystic ovary syndrome: a community-based cross-sectional study
    Bell, Robin J.
    Islam, Rakibul M.
    Skiba, Marina A.
    Herbert, Dilinie
    Garcia, Alejandra Martinez
    Davis, Susan R.
    [J]. HUMAN REPRODUCTION, 2022, 37 (01) : 109 - 118
  • [7] Anti-Milllerian hormone and polycystic ovary syndrome
    Bhide, Priya
    Homburg, Roy
    [J]. BEST PRACTICE & RESEARCH CLINICAL OBSTETRICS & GYNAECOLOGY, 2016, 37 : 38 - 45
  • [8] Intra- and inter-cycle variability of anti-Mullerian hormone (AMH) levels in healthy women during non-consecutive menstrual cycles: the BICYCLE study
    Biniasch, Marieke
    Laubender, Ruediger Paul
    Hund, Martin
    Buck, Katharina
    De Geyter, Christian
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2022, 60 (04) : 597 - 605
  • [9] Antimullerian hormone to determine polycystic ovarian morphology
    de Loos, Alexandra Dietz
    Hund, Martin
    Buck, Katharina
    Meun, Cindy
    Sillman, Johanna
    Laven, Joop S. E.
    [J]. FERTILITY AND STERILITY, 2021, 116 (04) : 1149 - 1157
  • [10] Intraobserver and interobserver reliability of automated antral follicle counts made using three-dimensional ultrasound and SonoAVC
    Deb, S.
    Jayaprakasan, K.
    Campbell, B. K.
    Clewes, J. S.
    Johnson, I. R.
    Raine-Fenning, N. J.
    [J]. ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2009, 33 (04) : 477 - 483