Analysis of Individual V•O2max Responses during a Cardiopulmonary Exercise Test and the Verification Phase in Physically Active Women

被引:1
作者
Succi, Pasquale J. [1 ]
Benitez, Brian [1 ]
Kwak, Minyoung [1 ]
Bergstrom, Haley C. [1 ]
机构
[1] Univ Kentucky, Dept Kinesiol & Hlth Promot, Lexington, KY 40536 USA
关键词
exercise test; women; verification phase; oxygen consumption; MAXIMAL OXYGEN-UPTAKE; O-2; UPTAKE; RELIABILITY; SUITABILITY; ATTAINMENT; CRITERIA; CONFIRM;
D O I
10.3390/jfmk8030124
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
This study aimed to investigate the test-retest reliability, mean, and individual responses in the measurement of maximal oxygen consumption ((VO2max)-O-center dot) during a cardiopulmonary exercise test (CPET) and the verification phase during cycle ergometry in women. Nine women (22 +/- 2 yrs, 166.0 +/- 4.5 cm, 58.6 +/- 7.7 kg) completed a CPET, passively rested for 5 min, and then completed a verification phase at 90% of peak power output to determine the highest (VO2)-O-center dot from the CPET ((VO2CPET)-O-center dot) and verification phase ((VO2verification)-O-center dot) on 2 separate days. Analyses included a two-way repeated measures ANOVA, intraclass correlation coefficients (ICC2,1), standard errors of the measurement (SEM), minimal differences (MD), and coefficients of variation (CoV). There was no test (test 1 versus test 2) x method (CPET vs. verification phase) interaction (p = 0.896) and no main effect for method (p = 0.459). However, test 1 (39.2 mL<middle dot>kg(-1)<middle dot>min(-1)) was significantly higher than test 2 (38.3 mL<middle dot>kg(-1)<middle dot>min(-1)) (p = 0.043). The (VO2CPET)-O-center dot (ICC = 0.984; CoV = 1.98%; SEM = 0.77 mL<middle dot>kg(-1)<middle dot>min(-1); MD = 2.14 mL<middle dot>kg(-1)<middle dot>min(-1)) and (VO2verification)-O-center dot (ICC = 0.964; CoV = 3.30%; SEM = 1.27 mL<middle dot>kg(-1)<middle dot>min(-1); MD = 3.52 mL<middle dot>kg(-1)<middle dot>min(-1)) demonstrated "excellent" reliability. Two subjects demonstrated a test 1 (VO2CPET)-O-center dot that exceeded the test 2 (VO2CPET)-O-center dot, and one subject demonstrated a test 1 (VO2verification)-O-center dot that exceeded the test 2 (VO2verification)-O-center dot by more than the respective CPET and verification phase MD. One subject demonstrated a (VO2CPET)-O-center dot that exceeded the (VO2verification)-O-center dot, and one subject demonstrated a (VO2verification)-O-center dot that exceeded the (VO2CPET)-O-center dot by more than the MD. These results demonstrate the importance of examining the individual responses in the measurement of the (VO2max)-O-center dot and suggest that the MD may be a useful threshold to quantify real individual changes in (VO2)-O-center dot.
引用
收藏
页数:12
相关论文
共 44 条
[1]  
[Anonymous], 2002, Journal Of Exercise Physiology
[2]  
Astorino Todd A, 2020, Int J Exerc Sci, V13, P1448
[3]   Efficacy of constant load verification testing to confirm VO2max attainment [J].
Astorino, Todd A. ;
DeRevere, Jamie .
CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2018, 38 (04) :703-709
[4]   Statistical methods for assessing measurement error (reliability) in variables relevant to sports medicine [J].
Atkinson, G ;
Nevill, AM .
SPORTS MEDICINE, 1998, 26 (04) :217-238
[5]  
BORG G, 1970, Scandinavian Journal of Rehabilitation Medicine, V2, P92
[6]   RELIABILITY OF NEUROMUSCULAR MEASUREMENTS DURING EXPLOSIVE ISOMETRIC CONTRACTIONS, WITH SPECIAL REFERENCE TO ELECTROMYOGRAPHY NORMALIZATION TECHNIQUES [J].
Buckthorpe, Matthew W. ;
Hannah, Ricci ;
Pain, Matthew T. G. ;
Folland, Jonathan P. .
MUSCLE & NERVE, 2012, 46 (04) :566-576
[7]   Is a verification phase useful for confirming maximal oxygen uptake in apparently healthy adults? A systematic review and meta-analysis [J].
Costa, Victor A. B. ;
Midgley, Adrian W. ;
Carroll, Sean ;
Astorino, Todd A. ;
de Paula, Tainah ;
Farinatti, Paulo ;
Cunha, Felipe A. .
PLOS ONE, 2021, 16 (02)
[8]   Suitability of Verification Testing to Confirm Attainment of VO2max in Middle-Aged and Older Adults [J].
Dalleck, Lance C. ;
Astorino, Todd A. ;
Erickson, Rachel M. ;
McCarthy, Caitlin M. ;
Beadell, Alyssa A. ;
Botten, Brigette H. .
RESEARCH IN SPORTS MEDICINE, 2012, 20 (02) :118-128
[9]   The maximally attainable Vo2 during exercise in humans:: the peak vs. maximum issue [J].
Day, JR ;
Rossiter, HB ;
Coats, EM ;
Skasick, A ;
Whipp, BJ .
JOURNAL OF APPLIED PHYSIOLOGY, 2003, 95 (05) :1901-1907
[10]  
DIONNE FT, 1991, MED SCI SPORT EXER, V23, P177