Case report: Transcatheter tricuspid valve-in-valve implantation using novel balloon-expandable aortic valve with 1 year follow-up

被引:2
作者
Mussayev, Abdurashid [1 ]
Alimbayev, Serik [2 ]
Tanaliev, Nursultan [3 ]
Kuanyshbek, Aidyn [4 ]
Marat, Aripov [5 ]
Lesbekov, Timur [6 ]
Raissov, Yerkezhan [7 ]
Sadykova, Aigerim [1 ]
Kamila, Askarovna Kenzhebayeva [8 ]
Mukarov, Murat [9 ]
Pya, Yuriy [10 ]
机构
[1] Natl Res Cardiac Surg Ctr, Cathlab, Astana, Kazakhstan
[2] Natl Res Cardiac Surg Ctr, Struct Heart Dis, Astana, Kazakhstan
[3] Natl Res Cardiac Surg Ctr, Dept Intervent Cardiol, Astana, Kazakhstan
[4] Natl Res Cardiac Surg Ctr, Dept Anesthesiol Resuscitat & Intens Care, Astana, Kazakhstan
[5] Natl Res Cardiac Surg Ctr, Dept Intervent Cardiol, Astana, Kazakhstan
[6] Natl Res Cardiac Surg Ctr, Dept Cardiac Surg, Astana, Kazakhstan
[7] Natl Res Cardiac Surg Ctr, Intervent Cardiol, Astana, Kazakhstan
[8] Minist Internal Affairs, Cent Hosp Polyclin, Astana, Kazakhstan
[9] Natl Res Cardiac Surg Ctr, Dept Cardiol, Astana, Kazakhstan
[10] Natl Res Cardiac Surg Ctr, Dept Cardiac Surg, Astana, Kazakhstan
关键词
bioprosthetic heart valve; balloon expandable heart valves; Myval transcatheter heart valve; tricuspid valve; valve-in-valve procedure; valvular heart disease; REPLACEMENT; STENOSIS;
D O I
10.3389/fcvm.2023.1152280
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Generally, the dysfunction or failure of bioprosthetic heart valves (BHVs) is managed by replacement surgery. In the case of tricuspid valve dysfunction, re-do surgery is rarely attempted because of the critically high risk of developing pulmonary hypertension, pulmonary embolism, and intraoperative mortality. Hence, transcatheter tricuspid repair and replacement procedures are preferred. More recently, transcatheter valve-in-valve (ViV) treatments have gained importance because of their less invasiveness, especially for patients with prior surgeries. Encouraging evidence of the safety and effectiveness of a novel balloon-expandable (BE) transcatheter heart valve (THV)-the Myval THV-has been reported for ViV procedures. Here, we present a case-series of 5 patients, in whom tricuspid ViV procedure was performed using BE Myval THV, implanted supra-annularly by anchoring onto the deteriorated BHV. This case-series details the procedural steps to prevent in-hospital adverse events and early (30-day) mortality and the challenges during tricuspid ViV interventions.
引用
收藏
页数:7
相关论文
共 21 条
[1]   Accessory pathway location algorithms: Planning invasive procedures in the electrophysiology laboratory [J].
Baranchuk, Adrian ;
Krishnan, Dhruv ;
Miranda-Arboleda, Andres F. .
KARDIOLOGIA POLSKA, 2022, 80 (01) :3-4
[2]  
Bapat Vinayak, 2014, EuroIntervention, V10 Suppl U, pU44, DOI 10.4244/EIJV10SUA7
[3]   Clinical Comparison of a Novel Balloon-Expandable Versus a Self-Expanding Transcatheter Heart Valve for the Treatment of Patients with Severe Aortic Valve Stenosis: The EVAL Registry [J].
Barki, Monica ;
Ielasi, Alfonso ;
Buono, Andrea ;
Maliandi, Gabriele ;
Pellicano, Mariano ;
Bande, Marta ;
Casilli, Francesco ;
Messina, Francesca ;
Uccello, Giuseppe ;
Briguglia, Daniele ;
Medda, Massimo ;
Tespili, Maurizio ;
Donatelli, Francesco .
JOURNAL OF CLINICAL MEDICINE, 2022, 11 (04)
[4]   Transcatheter tricuspid valve-in-valve implantation for degenerative surgical bio-prosthesis using SAPIEN 3: A case series [J].
Chandavimol, Mann ;
Ngernsritrakul, Tawai ;
Meemook, Krissada ;
Apinyasawat, Sirin ;
Tangcharoen, Tarinee ;
Pienvichit, Pavit ;
Samankatiwat, Piya ;
Boonbaichaiyapruck, Sarana .
CLINICAL CASE REPORTS, 2021, 9 (11)
[5]   Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis - First human case description [J].
Cribier, A ;
Eltchaninoff, H ;
Bash, A ;
Borenstein, N ;
Tron, C ;
Bauer, F ;
Derumeaux, G ;
Anselme, F ;
Laborde, F ;
Leon, MB .
CIRCULATION, 2002, 106 (24) :3006-3008
[6]   Early clinical and haemodynamic matched comparison of balloon-expandable valves [J].
Delgado-Arana, Jose R. ;
Gordillo-Monge, Maria X. ;
Halim, Jonathan ;
De Marco, Federico ;
Trani, Carlo ;
Martin, Pedro ;
Infusino, Fabio ;
Ancona, Marco ;
den Heijer, Peter ;
Bedogni, Francesco ;
Franco, Luis Nombela ;
Moreno, Raul ;
Sargella, Gennaro ;
Montorfano, Matteo ;
Aristizabal-Duque, Cristhian ;
Romero-Delgado, Teresa ;
Santos, Sandra ;
Barrero, Alejandro ;
Gomez Salvador, Itziar ;
IJsselmuiden, Sander ;
Redondo Dieguez, Alfredo ;
San Roman Calvar, Jose Alberto ;
Amat-Santos, Ignacio J. .
HEART, 2022, 108 (09) :725-732
[7]   Percutaneous tricuspid valve implantation in failing bioprosthesis [J].
Eicken, Andreas ;
Ewert, Peter .
CARDIOVASCULAR DIAGNOSIS AND THERAPY, 2018, 8 (06) :765-770
[8]   Transcatheter tricuspid valve implantation: A multicentre French study [J].
Godart, Francois ;
Baruteau, Alban-Elouen ;
Petit, Jerome ;
Riou, Jean-Yves ;
Sassolas, Francois ;
Lusson, Jean R. ;
Fraisse, Alain ;
Boudjemline, Younes .
ARCHIVES OF CARDIOVASCULAR DISEASES, 2014, 107 (11) :583-591
[9]   Percutaneous Edwards SAPIEN valve implantation in the tricuspid position: case report and review of literature [J].
Hoendermis, Elke S. ;
Douglas, Yvonne L. ;
van den Heuvel, Ad F. M. .
EUROINTERVENTION, 2012, 8 (05) :628-633
[10]   Transcatheter Valve-in-Valve Implantation With a Novel Balloon-Expandable Device in Patients With Bioprosthetic Heart Valve Failure: A Case Series [J].
Ielasi, Alfonso ;
Buono, Andrea ;
Medda, Massimo ;
Casilli, Francesco ;
Bande, Marta ;
Pellicano, Mariano ;
Glauber, Mattia ;
Donatelli, Francesco ;
Tespili, Maurizio .
CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2021, 28 :S98-S101