A Sliding Scale Signal Quality Metric of Photoplethysmography Applicable to Measuring Heart Rate across Clinical Contexts with Chest Mounting as a Case Study

被引:2
作者
McLean, Marnie K. K. [1 ]
Weaver, R. Glenn [1 ]
Lane, Abbi [1 ]
Smith, Michal T. T. [1 ]
Parker, Hannah [1 ]
Stone, Ben [2 ]
McAninch, Jonas [2 ]
Matolak, David W. W. [2 ]
Burkart, Sarah [1 ]
Chandrashekhar, M. V. S. [2 ]
Armstrong, Bridget [1 ]
机构
[1] Univ South Carolina, Dept Exercise Sci, Columbia, SC 29208 USA
[2] Univ South Carolina, Coll Engn & Comp, Columbia, SC 29208 USA
基金
美国国家卫生研究院;
关键词
photoplethysmography; PPG; heart rate; signal quality; MOTION ARTIFACT; PULSE OXIMETRY; MONITORING-SYSTEM; REDUCTION; AGREEMENT; ECG;
D O I
10.3390/s23073429
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Photoplethysmography (PPG) signal quality as a proxy for accuracy in heart rate (HR) measurement is useful in various public health contexts, ranging from short-term clinical diagnostics to free-living health behavior surveillance studies that inform public health policy. Each context has a different tolerance for acceptable signal quality, and it is reductive to expect a single threshold to meet the needs across all contexts. In this study, we propose two different metrics as sliding scales of PPG signal quality and assess their association with accuracy of HR measures compared to a ground truth electrocardiogram (ECG) measurement. Methods: We used two publicly available PPG datasets (BUT PPG and Troika) to test if our signal quality metrics could identify poor signal quality compared to gold standard visual inspection. To aid interpretation of the sliding scale metrics, we used ROC curves and Kappa values to calculate guideline cut points and evaluate agreement, respectively. We then used the Troika dataset and an original dataset of PPG data collected from the chest to examine the association between continuous metrics of signal quality and HR accuracy. PPG-based HR estimates were compared with reference HR estimates using the mean absolute error (MAE) and the root-mean-square error (RMSE). Point biserial correlations were used to examine the association between binary signal quality and HR error metrics (MAE and RMSE). Results: ROC analysis from the BUT PPG data revealed that the AUC was 0.758 (95% CI 0.624 to 0.892) for signal quality metrics of STD-width and 0.741 (95% CI 0.589 to 0.883) for self-consistency. There was a significant correlation between criterion poor signal quality and signal quality metrics in both Troika and originally collected data. Signal quality was highly correlated with HR accuracy (MAE and RMSE, respectively) between PPG and ground truth ECG. Conclusion: This proof-of-concept work demonstrates an effective approach for assessing signal quality and demonstrates the effect of poor signal quality on HR measurement. Our continuous signal quality metrics allow estimations of uncertainties in other emergent metrics, such as energy expenditure that relies on multiple independent biometrics. This open-source approach increases the availability and applicability of our work in public health settings.
引用
收藏
页数:16
相关论文
共 49 条
  • [1] Investigating sources of inaccuracy in wearable optical heart rate sensors
    Bent, Brinnae
    Goldstein, Benjamin A.
    Kibbe, Warren A.
    Dunn, Jessilyn P.
    [J]. NPJ DIGITAL MEDICINE, 2020, 3 (01)
  • [2] Heart Rate Estimation From Wrist-Worn Photoplethysmography: A Review
    Biswas, Dwaipayan
    Simoes-Capela, Neide
    Van Hoof, Chris
    Van Helleputte, Nick
    [J]. IEEE SENSORS JOURNAL, 2019, 19 (16) : 6560 - 6570
  • [3] Castaneda Denisse, 2018, Int J Biosens Bioelectron, V4, P195, DOI 10.15406/ijbsbe.2018.04.00125
  • [4] Criterion-related validity of the Borg ratings of perceived exertion scale in healthy individuals: a meta-analysis
    Chen, MJ
    Fan, XT
    Moe, ST
    [J]. JOURNAL OF SPORTS SCIENCES, 2002, 20 (11) : 873 - 899
  • [5] Arterial Wave Reflections and Incident Cardiovascular Events and Heart Failure: MESA (Multiethnic Study of Atherosclerosis)
    Chirinos, Julio A.
    Kips, Jan G.
    Jacobs, David R., Jr.
    Brumback, Lyndia
    Duprez, Daniel A.
    Kronmal, Richard
    Bluemke, David A.
    Townsend, Raymond R.
    Vermeersch, Sebastian
    Segers, Patrick
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 60 (21) : 2170 - 2177
  • [6] Photoplethysmograph Signal Reconstruction Based on a Novel Hybrid Motion Artifact Detection-Reduction Approach. Part I: Motion and Noise Artifact Detection
    Chong, Jo Woon
    Dao, Duy K.
    Salehizadeh, S. M. A.
    McManus, David D.
    Darling, Chad E.
    Chon, Ki H.
    Mendelson, Yitzhak
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 2014, 42 (11) : 2238 - 2250
  • [7] A COEFFICIENT OF AGREEMENT FOR NOMINAL SCALES
    COHEN, J
    [J]. EDUCATIONAL AND PSYCHOLOGICAL MEASUREMENT, 1960, 20 (01) : 37 - 46
  • [8] The Acceptability, Feasibility, and Effectiveness of Wearable Activity Trackers for Increasing Physical Activity in Children and Adolescents: A Systematic Review
    Creaser, Amy, V
    Clemes, Stacy A.
    Costa, Silvia
    Hall, Jennifer
    Ridgers, Nicola D.
    Barber, Sally E.
    Bingham, Daniel D.
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2021, 18 (12)
  • [9] A Robust Motion Artifact Detection Algorithm for Accurate Detection of Heart Rates From Photoplethysmographic Signals Using Time-Frequency Spectral Features
    Dao, Duy
    Salehizadeh, S. M. A.
    Noh, Yeonsik
    Chong, Jo Woon
    Cho, Chae Ho
    McManus, Dave
    Darling, Chad E.
    Mendelson, Yitzhak
    Chon, Ki H.
    [J]. IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2017, 21 (05) : 1242 - 1253
  • [10] DeCoster J., 2011, J EXP PSYCHOPATHOL, V2, P197, DOI [10.5127/jep.008310, DOI 10.5127/JEP.008310]