The Antibacterial Performance of Implant Coating Made of Vancomycin-Loaded Polymer Material: An In Vitro Study

被引:2
|
作者
Alenezi, Ali [1 ]
机构
[1] Qassim Univ, Coll Dent, Dept Prosthodont, Buraydah 52571, Saudi Arabia
来源
SURFACES | 2023年 / 6卷 / 03期
关键词
antibacterial; coating; implant; Poly(N-isopropylacrylamide); vancomycin; hydrophilicity; DRUG-DELIVERY; SURFACE CHARACTERISTICS; OSTEOBLAST FUNCTIONS; TITANIUM; RELEASE; CHITOSAN; POLY(N-ISOPROPYLACRYLAMIDE); INFECTIONS; ADHESION; BIOCOMPATIBILITY;
D O I
10.3390/surfaces6030022
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Bacterial adhesion and biofilm formation on the surface of titanium implants are the main causes of implant-associated infection. An antibacterial coating on the implant surface can reduce the risk of biofilm formation. The aim of this study was to investigate the bactericidal effects of a van-comycin-loaded polymer coated on an implant surface. For this purpose, poly(N-isopropylacrylamide) (PNIPAAm) was first synthesized as a homopolymer or by co-polymerization with acrylamide (PNIPAAm-AAm) at a 5% weight ratio. Then, thin and uniform polymer coatings were prepared using the spin coating technique. The degree of surface hydro-philicity of the polymer coatings was evaluated by measuring the water contact angle (CA). For the antibacterial tests, the polymer-coated surfaces were loaded with vancomycin. The tests were performed in three conditions: on a glass surface (control), on a PNIPAAm-AAm-coated surface, and on a PNIPAAm-AAm-coated surface loaded with vancomycin. The death rates of the bacteria in contact with the coated surfaces were evaluated at different temperatures with fluorescence microscopy. A scanning electron microscopy (SEM) analysis of cross sections of the polymer coatings revealed a uniform thin film of approximately 200 nm in thickness. The water contact angle analysis performed at different temperatures revealed that the polymer-coated surfaces were more hydrophobic (CAs ranging between 53 & DEG; and 63 & DEG;) than the uncoated glass surface (CA ranging between 15 & DEG; and 35 & DEG;). The bacterial death rate, measured at 40 & DEG;C or while continuously switching the temperature between 37 & DEG;C and 40 & DEG;C, was higher in the presence of the surface coated with vancomycin-loaded PNIPAAm-AAm than when using the other surfaces (p-value & LE; 0.001). The vancomycin-loaded polymer coating evaluated in this study exhibited effective antibacterial properties when the polymer reached the phase transition temperature.
引用
收藏
页码:304 / 315
页数:12
相关论文
共 50 条
  • [41] Effect of Low-Frequency Pulsed Ultrasound on Drug Delivery, Antibacterial Efficacy, and Bone Cement Degradation in Vancomycin-Loaded Calcium Phosphate Cement
    Shi, Mingmin
    Chen, Lei
    Wang, Yangxin
    Wang, Wei
    Yan, Shigui
    MEDICAL SCIENCE MONITOR, 2018, 24 : 797 - 802
  • [42] Intra-discal vancomycin-loaded PLGA microsphere injection for MRSA discitis: an experimental study
    Wang, Fei
    Ni, Bin
    Zhu, Zhuangchen
    Liu, Fucun
    Zhu, Yu-Zhao
    Liu, Jun
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2011, 131 (01) : 111 - 119
  • [43] Antibacterial and biofilm-inhibitory effects of vancomycin-loaded mesoporous silica nanoparticles on methicillin-resistant staphylococcus aureus and gram-negative bacteria
    Mohammad Yousef Memar
    Mina Yekani
    Safar Farajnia
    Farzaneh Ghadiri Moghaddam
    Edris Nabizadeh
    Simin Sharifi
    Solmaz Maleki Dizaj
    Archives of Microbiology, 2023, 205
  • [44] Enhanced silver loaded antibacterial titanium implant coating with novel hierarchical effect
    Zhang, Yanxian
    Dong, Chaofang
    Yang, Sefei
    Chiu, Te-Wei
    Wu, Junsheng
    Xiao, Kui
    Huang, Yunhua
    Li, Xiaogang
    JOURNAL OF BIOMATERIALS APPLICATIONS, 2018, 32 (09) : 1289 - 1299
  • [45] Mechanical and In Vitro Antibacterial Properties of a Porous Ti-6Al-4V Scaffold Combined with Vancomycin-Loaded Polymethyl Methacrylate by Three-Dimensional Printing
    Yao, Qing-Qiang
    Zhou, Jin
    Jiang, Chun-Zhi
    Sui, Ji-Sheng
    Li, Jia-Yi
    Xu, Yan
    Wu, Xiao-Ling
    Liu, Nancy Q.
    Buser, Zorica
    Wang, Li-Ming
    JOURNAL OF BIOMATERIALS AND TISSUE ENGINEERING, 2018, 8 (05) : 740 - 749
  • [46] Antibacterial effect of nanocurcumin inside the implant fixture: An in vitro study
    Negahdari, Ramin
    Ghavimi, Mohammad Ali
    Barzegar, Ali
    Memar, Mohammad Yousef
    Balazadeh, Ladan
    Bohlouli, Sepideh
    Sharifi, Simin
    Maleki Dizaj, Solmaz
    CLINICAL AND EXPERIMENTAL DENTAL RESEARCH, 2021, 7 (02): : 163 - 169
  • [47] Vancomycin-loaded porous chitosan-pectin-hydroxyapatite nanocomposite coating on Ti6Al4V towards enhancing prosthesis antiinfection performance
    Wang, Bo
    Peng, Kan
    Xu, Peng
    Jing, Wensen
    Zhang, Yingang
    MATERIALS LETTERS, 2023, 351
  • [48] Antibacterial Activity of Zinc-Doped Hydroxyapatite and Vancomycin-Loaded Gelatin Nanoparticles against Intracellular Staphylococcus aureus in Human THP-1 Derived Macrophages
    Cuypers, Lizzy A. B.
    de Boer, Leonie
    Wang, Rong
    Walboomers, X. Frank
    Yang, Fang
    Zaat, Sebastian A. J.
    Leeuwenburgh, Sander C. G.
    ACS APPLIED NANO MATERIALS, 2024, 7 (18) : 21964 - 21974
  • [49] Preparation and evaluation of blend polymer films for wound dressing using vancomycin-loaded polycaprolactone and carboxymethyl cellulose via crosslinking methods: Effect of mechanical strength, antibacterial activity, and cytotoxicity
    Meedecha, Paweena
    Srisang, Naruebodee
    Eawsakul, Komgrit
    Ongtanasup, Tassanee
    Tambunlertchai, Supreeda
    Sokjabok, Siwakon
    Chungcharoen, Thatchapol
    Srisang, Siriwan
    Limmun, Warunee
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2024, 151
  • [50] Spray coating of dual antibiotic-loaded nanospheres on orthopedic implant for prolonged release and enhanced antibacterial activity
    Horprasertkij, Kamonnart
    Dwivedi, Anupma
    Riansuwan, Kongkhet
    Kiratisin, Pattarachai
    Nasongkla, Norased
    JOURNAL OF DRUG DELIVERY SCIENCE AND TECHNOLOGY, 2019, 53