The Antibacterial Performance of Implant Coating Made of Vancomycin-Loaded Polymer Material: An In Vitro Study

被引:2
|
作者
Alenezi, Ali [1 ]
机构
[1] Qassim Univ, Coll Dent, Dept Prosthodont, Buraydah 52571, Saudi Arabia
来源
SURFACES | 2023年 / 6卷 / 03期
关键词
antibacterial; coating; implant; Poly(N-isopropylacrylamide); vancomycin; hydrophilicity; DRUG-DELIVERY; SURFACE CHARACTERISTICS; OSTEOBLAST FUNCTIONS; TITANIUM; RELEASE; CHITOSAN; POLY(N-ISOPROPYLACRYLAMIDE); INFECTIONS; ADHESION; BIOCOMPATIBILITY;
D O I
10.3390/surfaces6030022
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Bacterial adhesion and biofilm formation on the surface of titanium implants are the main causes of implant-associated infection. An antibacterial coating on the implant surface can reduce the risk of biofilm formation. The aim of this study was to investigate the bactericidal effects of a van-comycin-loaded polymer coated on an implant surface. For this purpose, poly(N-isopropylacrylamide) (PNIPAAm) was first synthesized as a homopolymer or by co-polymerization with acrylamide (PNIPAAm-AAm) at a 5% weight ratio. Then, thin and uniform polymer coatings were prepared using the spin coating technique. The degree of surface hydro-philicity of the polymer coatings was evaluated by measuring the water contact angle (CA). For the antibacterial tests, the polymer-coated surfaces were loaded with vancomycin. The tests were performed in three conditions: on a glass surface (control), on a PNIPAAm-AAm-coated surface, and on a PNIPAAm-AAm-coated surface loaded with vancomycin. The death rates of the bacteria in contact with the coated surfaces were evaluated at different temperatures with fluorescence microscopy. A scanning electron microscopy (SEM) analysis of cross sections of the polymer coatings revealed a uniform thin film of approximately 200 nm in thickness. The water contact angle analysis performed at different temperatures revealed that the polymer-coated surfaces were more hydrophobic (CAs ranging between 53 & DEG; and 63 & DEG;) than the uncoated glass surface (CA ranging between 15 & DEG; and 35 & DEG;). The bacterial death rate, measured at 40 & DEG;C or while continuously switching the temperature between 37 & DEG;C and 40 & DEG;C, was higher in the presence of the surface coated with vancomycin-loaded PNIPAAm-AAm than when using the other surfaces (p-value & LE; 0.001). The vancomycin-loaded polymer coating evaluated in this study exhibited effective antibacterial properties when the polymer reached the phase transition temperature.
引用
收藏
页码:304 / 315
页数:12
相关论文
共 50 条
  • [21] In vitro Antibacterial Activity of PLGA-PEG-PLGA Thermosensitive Hydrogels Loaded with Vancomycin
    Dong Xiaoming
    Yuan Baoming
    Chen Bingpeng
    He Chaoliang
    Wang Jincheng
    Chen Xuesi
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2017, 38 (05): : 866 - 871
  • [22] Efficacy of antibacterial-loaded coating in an in vivo model of acutely highly contaminated implant
    Giavaresi, Gianluca
    Meani, Enzo
    Sartori, Maria
    Ferrari, Andrea
    Bellini, Davide
    Sacchetta, Anna C.
    Meraner, Joachim
    Sambri, Andrea
    Vocale, Caterina
    Sambri, Vittorio
    Fini, Milena
    Romano, Carlo L.
    INTERNATIONAL ORTHOPAEDICS, 2014, 38 (07) : 1505 - 1512
  • [23] Vancomycin-Loaded in situ Gelled Hydrogel as an Antibacterial System for Enhancing Repair of Infected Bone Defects
    Sun, Shouye
    Wang, Qian
    Zhang, Bin
    Cui, Yutao
    Si, Xinghui
    Wang, Gan
    Wang, Jingwei
    Xu, Hang
    Yuan, Baoming
    Peng, Chuangang
    INTERNATIONAL JOURNAL OF NANOMEDICINE, 2024, 19 : 10227 - 10245
  • [24] Characterization and antibacterial performance of electrodeposited chitosan-vancomycin composite coatings for prevention of implant-associated infections
    Ordikhani, F.
    Tamjid, E.
    Simchi, A.
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2014, 41 : 240 - 248
  • [25] In vitro and in vivo drug release and antibacterial properties of the novel vancomycin-loaded bone-like hydroxyapatite/poly amino acid scaffold
    Cao, Zhidong
    Jiang, Dianming
    Yan, Ling
    Wu, Jun
    INTERNATIONAL JOURNAL OF NANOMEDICINE, 2017, 12 : 1841 - 1851
  • [26] Application of Porous Polyetheretherketone Scaffold/Vancomycin-Loaded Thermosensitive Hydrogel Composites for Antibacterial Therapy in Bone Repair
    Qi, Desheng
    Wang, Ningning
    Cheng, Yuanqiang
    Zhao, Yao
    Meng, Lingcheng
    Yue, Xigui
    She, Peng
    Gao, Hang
    MACROMOLECULAR BIOSCIENCE, 2022, 22 (10)
  • [27] Development of dental implant coating with minocycline-loaded niosome for antibacterial application
    Wongsuwan, Nattarat
    Dwivedi, Anupma
    Tancharoen, Salunya
    Nasongkla, Norased
    JOURNAL OF DRUG DELIVERY SCIENCE AND TECHNOLOGY, 2020, 56
  • [28] Assessing the character of the rhBMP-2-and vancomycin-loaded calcium sulphate composites in vitro and in vivo
    Wang, Yulu
    Wang, Xinqiang
    Li, Hang
    Xue, Deting
    Shi, Zhongli
    Qi, Yiying
    Ma, Qiang
    Pan, Zhijun
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2011, 131 (07) : 991 - 1001
  • [29] Tubular Electrospun Vancomycin-Loaded Vascular Grafts: Formulation Study and Physicochemical Characterization
    Dorati, Rossella
    Chiesa, Enrica
    Rosalia, Mariella
    Pisani, Silvia
    Genta, Ida
    Bruni, Giovanna
    Modena, Tiziana
    Conti, Bice
    POLYMERS, 2021, 13 (13)
  • [30] Development of Vancomycin-Loaded Polysaccharide-Based Hydrogel Wound Dressings: In Vitro and In Vivo Evaluation
    Mali, Kailas K.
    Dhawale, Shashikant C.
    Dias, Remeth J.
    Ghorpade, Vishwajeet S.
    Dhane, Nikhil S.
    ASIAN JOURNAL OF PHARMACEUTICS, 2018, 12 (02) : 94 - 105