Accuracy of continuous photoplethysmography-based 1 min mean heart rate assessment during atrial fibrillation

被引:11
作者
Hermans, Astrid N. L. [1 ]
Isaksen, Jonas L. [2 ]
Gawalko, Monika [1 ,3 ,4 ]
Pluymaekers, Nikki A. H. A. [1 ]
van der Velden, Rachel M. J. [1 ]
Snippe, Hilco [1 ]
Evens, Stijn [5 ]
De Witte, Glenn [5 ]
Luermans, Justin G. L. M. [1 ,6 ]
Manninger, Martin [7 ]
Lumens, Joost [8 ]
Kanters, Jorgen K. [2 ]
Linz, Dominik [1 ,2 ,6 ,9 ]
机构
[1] Maastricht Univ, Med Ctr, Cardiovasc Res Inst Maastricht, Dept Cardiol, P Debyelaan 25, NL-6229 HX Maastricht, Netherlands
[2] Univ Copenhagen, Fac Hlth & Med Sci, Dept Biomed Sci, Norregade 10, DK-1165 Copenhagen, Denmark
[3] Univ Duisburg Essen, Inst Pharmacol, West German Heart & Vasc Ctr, Forsthausweg 2, D-47057 Duisburg, Germany
[4] Med Univ Warsaw, Dept Cardiol 1, Zwirki i Wigury 61, PL-02091 Warsaw, Poland
[5] Qompium NV, Kemp Steenweg 293-16, B-3500 Hasselt, Belgium
[6] Radboud Univ Nijmegen, Med Ctr, Dept Cardiol, Geert Grooteplein Zuid 10, NL-6525 GA Nijmegen, Netherlands
[7] Med Univ Graz, Dept Internal Med, Div Cardiol, Auenbruggerpl 2, A-8036 Graz, Austria
[8] Maastricht Univ, Cardiovasc Res Inst Maastricht CARIM, Dept Biomed Engn, Minderbroedersberg 4-6, NL-6211 LK Maastricht, Netherlands
[9] Univ Adelaide, Royal Adelaide Hosp, Ctr Heart Rhythm Disorders, Port Rd, Adelaide, SA 5000, Australia
来源
EUROPACE | 2023年 / 25卷 / 03期
关键词
Persistent atrial fibrillation; 1 min mean heart rate assessment; Photoplethysmography; Electrocardiography; Mobile health; RHYTHM;
D O I
10.1093/europace/euad011
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Although mobile health tools using photoplethysmography (PPG) technology have been validated for the detection of atrial fibrillation (AF), their utility for heart rate assessment during AF remains unclear. Therefore, we aimed to evaluate the accuracy of continuous PPG-based 1 min mean heart rate assessment during AF. Methods and results Persistent AF patients were provided with Holter electrocardiography (ECG) (for >= 24 h) simultaneously with a PPG-equipped smartwatch. Both the PPG-based smartwatch and Holter ECG automatically and continuously monitored patients' heart rate/rhythm. ECG and PPG recordings were synchronized and divided into 1 min segments, from which a PPG-based and an ECG-based average heart rate estimation were extracted. In total, 47 661 simultaneous ECG and PPG 1 min heart rate segments were analysed in 50 patients (34% women, age 73 +/- 8 years). The agreement between ECG-determined and PPG-determined 1 min mean heart rate was high [root mean squared error (RMSE): 4.7 bpm]. The 1 min mean heart rate estimated using PPG was accurate within +/- 10% in 93.7% of the corresponding ECG-derived 1 min mean heart rate segments. PPG-based 1 min mean heart rate estimation was more often accurate during night-time (97%) than day-time (91%, P < 0.001) and during low levels (96%) compared to high levels of motion (92%, P < 0.001). A neural network with a 10 min history of the recording did not further improve the PPG-based 1 min mean heart rate assessment [RMSE: 4.4 (95% confidence interval: 3.5-5.2 bpm)]. Only chronic heart failure was associated with a lower agreement between ECG-derived and PPG-derived 1 min mean heart rates (P = 0.040). Conclusion During persistent AF, continuous PPG-based 1 min mean heart rate assessment is feasible in 60% of the analysed period and shows high accuracy compared with Holter ECG for heart rates <110 bpm.
引用
收藏
页码:835 / 844
页数:10
相关论文
共 24 条
  • [1] Reimbursement practices for use of digital devices in atrial fibrillation and other arrhythmias: a European Heart Rhythm Association survey
    Boriani, Giuseppe
    Svennberg, Emma
    Guerra, Federico
    Linz, Dominik
    Casado-Arroyo, Ruben
    Malaczynska-Rajpold, Katarzyna
    Duncker, David
    Boveda, Serge
    Merino, Jose Luis
    Leclercq, Christophe
    [J]. EUROPACE, 2022, 24 (11): : 1834 - 1843
  • [2] Heart rate dynamics distinguish among atrial fibrillation, normal sinus rhythm and sinus rhythm with frequent ectopy
    Carrara, Marta
    Carozzi, Luca
    Moss, Travis J.
    de Pasquale, Marco
    Cerutti, Sergio
    Ferrario, Manuela
    Lake, Douglas E.
    Moorman, J. Randall
    [J]. PHYSIOLOGICAL MEASUREMENT, 2015, 36 (09) : 1873 - 1888
  • [3] Assessing hemodynamics from the photoplethysmogram to gain insights into vascular age: a review from VascAgeNet
    Charlton, Peter H.
    Paliakait, Birute
    Pilt, Kristjan
    Bachler, Martin
    Zanelli, Serena
    Kulin, Daniel
    Allen, John
    Hallab, Magid
    Bianchini, Elisabetta
    Mayer, Christopher C.
    Terentes-Printzios, Dimitrios
    Dittrich, Verena
    Hametner, Bernhard
    Veerasingam, Dave
    Zikic, Dejan
    Marozas, Vaidotas
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2022, 322 (04): : H493 - H522
  • [4] Atrial Fibrillation JACC Council Perspectives
    Chung, Mina K.
    Refaat, Marwan
    Shen, Win-Kuang
    Kutyifa, Valentina
    Cha, Yong-Mei
    Di Biase, Luigi
    Baranchuk, Adrian
    Lampert, Rachel
    Natale, Andrea
    Fisher, John
    Lakkireddy, Dhanunjaya R.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 75 (14) : 1689 - 1713
  • [5] Graves A, 2012, STUD COMPUT INTELL, V385, P1, DOI [10.1162/neco.1997.9.1.1, 10.1007/978-3-642-24797-2]
  • [6] Monitoring of heart rate and inter-beat intervals with wrist plethysmography in patients with atrial fibrillation
    Harju, Jarkko
    Tarniceriu, Adrian
    Parak, Jakub
    Vehkaoja, Antti
    Yli-Hankala, Arvi
    Korhonen, Ilkka
    [J]. PHYSIOLOGICAL MEASUREMENT, 2018, 39 (06)
  • [7] Hassan MA, 2017, IEEE ENG MED BIO, P2851, DOI 10.1109/EMBC.2017.8037451
  • [9] Rhythm or rate control in atrial fibrillation - Pharmacological intervention in atrial fibrillation (PIAF): a randomised trial
    Hohnloser, SH
    Kuck, KH
    Lilienthal, J
    [J]. LANCET, 2000, 356 (9244) : 1789 - 1794
  • [10] Artificial intelligence for the detection, prediction, and management of atrial fibrillation; [Erkennung, Vorhersage und Behandlung von Vorhofflimmern mithilfe künstlicher Intelligenz]
    Isaksen J.L.
    Baumert M.
    Hermans A.N.L.
    Maleckar M.
    Linz D.
    [J]. Herzschrittmachertherapie + Elektrophysiologie, 2022, 33 (1) : 34 - 41