An approach to generate synthetic 4DCT datasets to benchmark Mid-Position implementations

被引:1
作者
Ghareeb, Firass [1 ]
Boukerroui, Djamal [2 ]
Stroom, Joep [1 ,4 ]
Jackson, Edward [3 ]
Pereira, Mariana [1 ]
Gooding, Mark [2 ]
Greco, Carlo [1 ]
机构
[1] Champalimaud Fdn, Dept Radiat Oncol, Lisbon, Portugal
[2] Mirada Med Ltd, Oxford, England
[3] Netherlands Canc Inst, Amsterdam, Netherlands
[4] Champalimaud Fdn, Dept Radiat Oncol, Av Brasilia, S N Doca Pedroucos, P-1400038 Lisbon, Portugal
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2023年 / 114卷
基金
“创新英国”项目;
关键词
Mid-Position; Evaluation; Synthetic; 4DCT; Deformable image registration; 4-DIMENSIONAL COMPUTED-TOMOGRAPHY; IMAGE REGISTRATION ALGORITHMS; LUNG-CANCER; RADIATION-THERAPY; CT SCANS; RADIOTHERAPY; VENTILATION; QUALITY; ACCURACY; MARGINS;
D O I
10.1016/j.ejmp.2023.103144
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The Mid-Position image is constructed from 4DCT data using Deformable Image Registration and can be used as planning CT with reduced PTV volumes. 4DCT datasets currently-available for testing do not provide the corresponding Mid-P images of the datasets. This work describes an approach to generate human-like synthetic 4DCT datasets with the associated Mid-P images that can be used as reference in the validation of Mid-P implementations. Methods: Twenty synthetic 4DCT datasets with the associated reference Mid-P images were generated from twenty clinical 4DCT datasets. Per clinical dataset, an anchor phase was registered to the remaining nine phases to obtain nine Deformable Vector Fields (DVFs). These DVFs were used to warp the anchor phase in order to generate the synthetic 4DCT dataset and the corresponding reference Mid-P image. Similarly, a reference 4D tumor mask dataset and its corresponding Mid-P tumor mask were generated. The generated synthetic datasets and masks were used to compare and benchmark the outcomes of three independent Mid-P implementations using a set of experiments.Results: The Mid-P images constructed by the three implementations showed high similarity scores when compared to the reference Mid-P images except for one noisy dataset. The biggest difference in the estimated motion amplitudes (-2.6 mm) was noticed in the Superior-Inferior direction. The statistical analysis showed no significant differences among the three implementations for all experiments. Conclusion: The described approach and the proposed experiments provide an independent method that can be used in the validation of any Mid-P implementation being developed.
引用
收藏
页数:11
相关论文
共 43 条
[1]  
[Anonymous], 2007, 15 INT C USE COMP RA
[2]   Mid-position treatment strategy for locally advanced lung cancer: a dosimetric study [J].
Ayadi, M. ;
Baudier, T. ;
Bouilhol, G. ;
Dupuis, P. ;
Boissard, P. ;
Pinho, R. ;
Krason, A. ;
Rit, S. ;
Claude, L. ;
Sarrut, D. .
BRITISH JOURNAL OF RADIOLOGY, 2020, 93 (1110)
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   Use of image registration and fusion algorithms and techniques in radiotherapy: Report of the AAPM Radiation Therapy Committee Task [J].
Brock, Kristy K. ;
Mutic, Sasa ;
McNutt, Todd R. ;
Li, Hua ;
Kessler, Marc L. .
MEDICAL PHYSICS, 2017, 44 (07) :E43-E76
[5]   On the Mathematical Properties of the Structural Similarity Index [J].
Brunet, Dominique ;
Vrscay, Edward R. ;
Wang, Zhou .
IEEE TRANSACTIONS ON IMAGE PROCESSING, 2012, 21 (04) :1488-1499
[6]   A framework for evaluation of deformable image registration spatial accuracy using large landmark point sets [J].
Castillo, Richard ;
Castillo, Edward ;
Guerra, Rudy ;
Johnson, Valen E. ;
McPhail, Travis ;
Garg, Amit K. ;
Guerrero, Thomas .
PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (07) :1849-1870
[7]   A simple fixed-point approach to invert a deformation field [J].
Chen, Mingli ;
Lu, Weiguo ;
Chen, Quan ;
Ruchala, Kenneth J. ;
Olivera, Gustavo H. .
MEDICAL PHYSICS, 2008, 35 (01) :81-88
[8]  
Crum WR, 2007, LECT NOTES COMPUT SC, V4791, P900
[9]   Can CT scan protocols used for radiotherapy treatment planning be adjusted to optimize image quality and patient dose? A systematic review [J].
Davis, Anne T. ;
Palmer, Antony L. ;
Nisbet, Andrew .
BRITISH JOURNAL OF RADIOLOGY, 2017, 90 (1076)
[10]   ITV, mid-ventilation, gating or couch tracking - A comparison of respiratory motion-management techniques based on 4D dose calculations [J].
Ehrbar, Stefanie ;
Johl, Alexander ;
Tartas, Adrianna ;
Stark, Luisa Sabrina ;
Riesterer, Oliver ;
Klock, Stephan ;
Guckenberger, Matthias ;
Tanadini-Lang, Stephanie .
RADIOTHERAPY AND ONCOLOGY, 2017, 124 (01) :80-88