Energy-saving potential analysis of a CO2 two-phase thermosyphon loop system used in data centers

被引:13
作者
Tong, Zhen [1 ]
Wang, Wencheng [1 ]
Fang, Chunxue [1 ]
机构
[1] Qingdao Univ Technol, Sch Environm & Municipal Engn, Qingdao 266033, Peoples R China
关键词
CO2; Thermosyphon loop; Data center; Experiment; Energy consumption; BOILING HEAT-TRANSFER; PRESSURE-DROP; PIPE SYSTEM; PERFORMANCE;
D O I
10.1016/j.energy.2023.127328
中图分类号
O414.1 [热力学];
学科分类号
摘要
Recently, the rapid development of data centers has led to an increased requirement of cooling systems, resulting in high energy consumption. A two-phase thermosyphon loop (TPTL) system effectively utilizes a natural cold source and reduces energy consumption in data centers. In this study, an experiment was conducted to compare the heat transfer performance of CO2 TPTL with the commonly used R134a and R410A TPTLs. Under their respective optimal filling ratios, CO2 TPTL exhibited the lowest required driving temperature difference, which was 3 degrees C lower than that of R410A TPTL and 5 degrees C lower than that of R134a TPTL. The energy-saving effect of CO2 TPTL was analyzed based on a typical data center case and the climate parameters of different cities in China. In Beijing, the annual average PUE (power usage effectiveness) of the data center using conventional centralized cooling systems, R134a TPTL, R410A TPTL, and CO2 TPTL was 1.43, 1.36, 1.34, and 1.32, respec-tively. The calculation for other cities showed that the energy saving ratios of the CO2 TPTL system in Kunming were the highest. They were 58.6%, 40.7%, and 30.4% higher compared with those of conventional centralized cooling system, R134a TPTL, and R410A TPTL, respectively.
引用
收藏
页数:8
相关论文
共 29 条
[1]  
[Anonymous], 2015, TC99 ASHRAE, V4nd, P14
[2]   Characteristic map of working mediums in closed loop two-phase thermosyphon: Thermal resistance and pressure [J].
Bai, Ye ;
Wang, Liang ;
Zhang, Shuang ;
Lin, Xipeng ;
Peng, Long ;
Chen, Haisheng .
APPLIED THERMAL ENGINEERING, 2020, 174
[3]   Experimental investigations and modeling of a loop thermosyphon for cooling with zero electrical consumption [J].
Chehade, Ali ;
Louahlia-Gualous, Hasna ;
Le Masson, Stephane ;
Lepinasse, Eric .
APPLIED THERMAL ENGINEERING, 2015, 87 :559-573
[4]   Experimental study on a loop thermosyphon cooling system in data centers using CO2 as a working Fluid, especially thermal environment and energy-saving effect [J].
Ding, Tao ;
Cao, Han Wen ;
He, Zhi Guang ;
Wu, Jun Da ;
Li, Zhen .
APPLIED THERMAL ENGINEERING, 2020, 175
[5]   Boiling heat transfer characteristics of the R744 coolant in the evaporator of the separated heat pipe system [J].
Ding, Tao ;
Cao, Han Wen ;
He, Zhi Guang ;
Li, Zhen .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2017, 113 :1254-1264
[6]   Experiment research on influence factors of the separated heat pipe system, especially the filling ratio and Freon types [J].
Ding, Tao ;
Cao, Han Wen ;
He, Zhi Guang ;
Li, Zhen .
APPLIED THERMAL ENGINEERING, 2017, 118 :357-364
[7]   Application of separated heat pipe system in data center cooling [J].
Ding, Tao ;
He, Zhi Guang ;
Hao, Tian ;
Li, Zhen .
APPLIED THERMAL ENGINEERING, 2016, 109 :207-216
[8]   Experimental investigation of geyser boiling in a small diameter two-phase loop thermosyphon [J].
Elkholy, A. ;
Kempers, R. .
EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2020, 118
[9]   Thermal performance of a two-phase loop thermosyphon with an additively manufactured evaporator [J].
Elkholy, Ahmed ;
Unlusoy, Can ;
Kempers, Roger .
APPLIED THERMAL ENGINEERING, 2022, 202
[10]   Experimental analysis of Closed Loop Two Phase Thermosyphon (CLTPT) for energy systems [J].
Franco, Alessandro ;
Filippeschi, Sauro .
EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2013, 51 :302-311