Effectiveness of Extra-Short (< 6 mm) Implants Compared to Standard-Length Implants Associated with Bone Graft: Systematic Review

被引:3
作者
Mendes, Polianne Alves [1 ]
Silva, Vania Eloisa de Araujo [1 ]
da Costa, Danilo Viegas [1 ]
de Pinho, Matheus Morals [1 ]
Chambrone, Leandro [2 ,3 ]
Zenobio, Elton Goncalves [1 ]
机构
[1] Pontificia Univ Catolica Minas Gerais, Belo Horizonte, MG, Brazil
[2] Ctr Invest Interdisciplinary Egas Moniz CiiEM, Evidence Based Hub, Almada, Portugal
[3] Univ Penn, Dept Periodont, Philadelphia, PA USA
关键词
biomechanical phenomena; bone grafting; dental implants; implant-supported dental prosthesis; meta-analysis; systematic review; SHORT DENTAL IMPLANTS; INCORPORATED TITANIUM SURFACE; X; 4.0; MM; LONGER IMPLANTS; AUGMENTED BONE; MULTICENTER; DIAMETER; RATIO;
D O I
10.11607/jomi.9990
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To evaluate the effectiveness of extra-short implants compared to standard-length implants in graft regions at different longitudinal follow-up times. Materials and Methods: A systematic review was performed, following PRISMA criteria. LILACS, MEDLINE/PubMed, Cochrane Library, and Embase databases, including gray literature and manual searches, were conducted without language or date restrictions. Study selection, risk of bias (Rob 2.O), quality of evidence (GRADE), and data collection were performed by two independent reviewers. Disagreements were resolved by a third reviewer. Data were combined using the random-effects model. Results: A total of 1,383 publications were identified, including 11 publications from 4 randomized clinical trials that evaluated 567 implants (276 extra-short and 291 regular implants with graft) in 186 patients. The meta-analysis showed that losses (risk ratio [RR]: 1.24; 95% CI: O.53 to 2.89; P = .62; 12: O%) and prosthetic complications (RR: O.89; 95% CI: O.31 to 2.59; P = .83; 12: O%) were similar in both groups. Biologic complications were significantly higher in regular implants with graft (RR: O.48; CI: O.29 to O.77; P=.003;12:18%), which also had lower peri-implant bone stability in the mandible at the 12-month follow-up (mean deviation [MD]:-O.25; CI:-O.36 to O.15; P < .OOOO1;12= O%). Conclusion: Extra-short implants showed similar effictiveness compared to standard-length implants placed in grafted regions at different longitudinal follow-up times and present reduced biologic complications, shorter treatment times, and greater peri-implant bone crest stability.
引用
收藏
页码:29 / +
页数:13
相关论文
共 40 条
  • [1] Dental Implant Length and Diameter: A Proposed Classification Scheme
    Al-Johany, Sulieman S.
    Al Amri, Mohammad D.
    Alsaeed, Suliman
    Alalola, Bassam
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2017, 26 (03): : 252 - 260
  • [2] Implant Survival and Crestal Bone Loss Around Extra-Short Implants Supporting a Fixed Denture: The Effect of Crown Height Space, Crown-to-Implant Ratio, and Offset Placement of the Prosthesis
    Anitua, Eduardo
    Hamdan Alkhraist, Mohammad
    Pinas, Laura
    Begona, Leire
    Orive, Gorka
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2014, 29 (03) : 682 - 689
  • [3] Short Dental Implants: A Systematic Review
    Annibali, S.
    Cristalli, M. P.
    Dell'Aquila, D.
    Bignozzi, I.
    La Monaca, G.
    Pilloni, A.
    [J]. JOURNAL OF DENTAL RESEARCH, 2012, 91 (01) : 25 - 32
  • [4] Bolle C, 2018, EUR J ORAL IMPLANTOL, V11, P31
  • [5] Influence of platform diameter in the reliability and failure mode of extra short dental implants
    Bordin, Dimorvan
    Bergamo, Edmara T. P.
    Bonfante, Estevam A.
    Fardin, Vinicius P.
    Coelho, Paulo G.
    [J]. JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2018, 77 : 470 - 474
  • [6] Grading quality of evidence and strength of recommendations in clinical practice guidelines Part 3 of 3. The GRADE approach to developing recommendations
    Brozek, J. L.
    Akl, E. A.
    Compalati, E.
    Kreis, J.
    Terracciano, L.
    Fiocchi, A.
    Ueffing, E.
    Andrews, J.
    Alonso-Coello, P.
    Meerpohl, J. J.
    Lang, D. M.
    Jaeschke, R.
    Williams, J. W., Jr.
    Phillips, B.
    Lethaby, A.
    Bossuyt, P.
    Glasziou, P.
    Helfand, M.
    Watine, J.
    Afilalo, M.
    Welch, V.
    Montedori, A.
    Abraha, I.
    Horvath, A. R.
    Bousquet, J.
    Guyatt, G. H.
    Schuenemann, H. J.
    [J]. ALLERGY, 2011, 66 (05) : 588 - 595
  • [7] Cannizzaro G, 2018, EUR J ORAL IMPLANTOL, V11, P295
  • [8] Cannizzaro G, 2015, EUR J ORAL IMPLANTOL, V8, P27
  • [9] Clinical relevance of dimensional bone and soft tissue alterations post-extraction in esthetic sites
    Chappuis, Vivianne
    Araujo, Mauricio G.
    Buser, Daniel
    [J]. PERIODONTOLOGY 2000, 2017, 73 (01) : 73 - 83
  • [10] Evaluation of Different Heights of Prosthetic Crowns Supported by an Ultra-Short Implant Using Three-Dimensional Finite Element Analysis
    Elias, Douglas Maximo
    Valerio, Claudia Scigliano
    de Oliveira, Dauro Douglas
    Manzi, Flavio Ricardo
    Zenobio, Elton Goncalves
    Seraidarian, Paulo Isaias
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2020, 33 (01) : 81 - 90