Development and Fabrication of a Molecularly Imprinted Polymer-Based Electroanalytical Sensor for the Determination of Acyclovir

被引:4
作者
Al Faysal, Abdullah [1 ]
Cetinkaya, Ahmet [2 ,3 ]
Kaya, Sariye Irem [4 ]
Erdogan, Taner [5 ]
Ozkan, Sibel A. [2 ]
Golcu, Aysegul [1 ]
机构
[1] Istanbul Tech Univ, Fac Sci & Letters, Dept Chem, TR-34469 Istanbul, Turkiye
[2] Ankara Univ, Fac Pharm, Dept Analyt Chem, TR-06560 Ankara, Turkiye
[3] Ankara Univ, Grad Sch Hlth Sci, TR-06110 Ankara, Turkiye
[4] Univ Hlth Sci, Gulhane Fac Pharm, Dept Analyt Chem, TR-06018 Ankara, Turkiye
[5] Kocaeli Univ, Kocaeli Vocat Sch, Dept Chem & Chem Proc Technol, TR-41140 Kocaeli, Turkiye
关键词
ANTIVIRAL DRUG ACYCLOVIR; ELECTROCHEMICAL SENSOR; NANOPARTICLES; SAFETY; OPTIMIZATION; COMPOSITE; HYDROGELS; LIQUID;
D O I
10.1021/acsomega.3c09399
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Acyclovir (ACV), a synthetic nucleoside derivative of purine, is one of the most potent antiviral medications recommended in the specific management of varicella-zoster and herpes simplex viruses. The molecularly imprinted polymer (MIP) was utilized to create an effective and specific electrochemical sensor using a straightforward photopolymerization process to determine ACV. The polymeric thin coating was developed using the template molecule ACV, a functional monomer acrylamide, a basic monomer 2-hydroxyethyl methacrylate, a cross-linker ethylene glycol dimethacrylate, and a photoinitiator 2-hydroxy-2-methyl propiophenone on the exterior of the glassy carbon electrode (GCE). Scanning electron microscopy, attenuated total reflectance-Fourier transform infrared spectroscopy, electrochemical impedance spectroscopy, and cyclic voltammetry were employed for the purpose of characterizing the constructed sensor (AM-ACV@MIP/GCE). Differential pulse voltammetry and a 5 mM ferrocyanide/ferricyanide ([Fe(CN)(6)](3-/4-)) redox reagent were used to detect the ACV binding to the specific cavities on MIP. The study involves density functional theory (DFT) calculations, which were conducted to investigate template-functional monomer interactions thoroughly, calculate template-functional monomer interaction energies, and determine the optimal template/functional monomer ratio. DFT calculations were performed using Becke's three-parameter hybrid functional with the Lee-Yang-Parr correlation functional (B3LYP) method and 6-31G(d,p) basis set. The sensor exhibits linear performance throughout the concentration region 1 x 10(-11) to 1 x 10(-10) M, and the limit of detection and limit of quantification were 7.15 x 10(-13) M and 2.38 x 10(-12) M, respectively. For the electrochemical study of ACV, the sensor demonstrated high accuracy, precision, robustness, and a short detection time. Furthermore, the developed electrochemical sensor exhibited exceptional recovery in tablet dosage form and commercial human blood samples, with recoveries of 99.40 and 100.44%, respectively. The findings showed that the AM-ACV@MIP/GCE sensor would effectively be used to directly assess pharmaceuticals from actual specimens and would particularly detect ACV compared to structurally similar pharmaceutical compounds.
引用
收藏
页码:9564 / 9576
页数:13
相关论文
共 50 条
[1]  
Ajima U., 2015, J. App. Pharm. Sci, V5, P065, DOI [10.7324/JAPS.2015.50411, DOI 10.7324/JAPS.2015.50411]
[2]   Synthesis, Characterization and Safety Evaluation of Sericin-Based Hydrogels for Controlled Delivery of Acyclovir [J].
Al-Tabakha, Moawia M. ;
Khan, Shujaat Ali ;
Ashames, Akram ;
Ullah, Hamid ;
Ullah, Kaleem ;
Murtaza, Ghulam ;
Hassan, Nageeb .
PHARMACEUTICALS, 2021, 14 (03)
[3]   Simultaneous determination of doxorubicin and dasatinib as two breast anticancer drugs uses an amplified sensor with ionic liquid and ZnO nanoparticle [J].
Alavi-Tabari, Seyed A. R. ;
Khalilzadeh, Mohammad A. ;
Karimi-Maleh, Hassan .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2018, 811 :84-88
[4]  
Aristov N., 2015, World Journal of Chemical Education, V3, P119, DOI DOI 10.12691/WJCE-3-5-2
[5]   FT-IR and FT-Raman spectra of 2-hydroxyethyl methacrylate - A conformational and vibrational analysis [J].
Belaidi, O. ;
Adjim, M. ;
Bouchaour, T. ;
Maschke, U. .
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2015, 148 :396-404
[6]  
Biovia D. S., 2016, DISCOVERYSTUDIO VISU
[7]   Carbon Electrode Modified with Molecularly Imprinted Polymers for the Development of Electrochemical Sensor: Application to Pharmacy, Food Safety, Environmental Monitoring, and Biomedical Analysis [J].
Bou-Maroun, Elias .
CHEMOSENSORS, 2023, 11 (11)
[8]   Two different molecularly imprinted polymeric coating techniques for creating sensitive and selective electrochemical sensors for the detection of Ribavirin [J].
Cetinkaya, Ahmet ;
Unal, M. Altay ;
Nazir, Hasan ;
Corman, M. Emin ;
Uzun, Lokman ;
Ozkan, Sibel A. .
SENSORS AND ACTUATORS B-CHEMICAL, 2023, 389
[9]  
Charithra M.M., 2021, Chem. Data Collect, V33, DOI [10.1016/j.cdc.2021.100718, DOI 10.1016/J.CDC.2021.100718]
[10]   Preparation and Evaluation of Novel In Situ Gels Containing Acyclovir for the Treatment of Oral Herpes Simplex Virus Infections [J].
Chaudhary, Binu ;
Verma, Surajpal .
SCIENTIFIC WORLD JOURNAL, 2014,