Strength and Deformation of Concrete-Encased Grouting-Filled Steel Tubes Columns Exposed to Monotonic Quasi-Static Loading Conditions

被引:5
作者
Abbood, Ahlam A. [1 ]
Oukaili, Nazar [1 ]
Allawi, Abbas A. [1 ]
Wardeh, George [2 ]
机构
[1] Univ Baghdad, Dept Civil Engn, Baghdad 17001, Iraq
[2] CY Cergy Paris Univ, L2MGC, F-95031 Neuville Sur Oise, France
关键词
encased concrete column; steel tube; grouting material; spiral pitch; interaction diagram; CFST STUB COLUMNS; BEHAVIOR;
D O I
10.3390/infrastructures9020026
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study aimed to evaluate the effectiveness of a novel concrete-encased column (CE) using small circular steel tubes filled with cementitious grouting material (GFST) as the primary reinforcement instead of traditional steel bars. The research involved three different types of reinforcement: conventional steel bars, concrete-filled steel tubes with 30% of the reinforcement ratio of steel bars, and concrete-filled steel tubes with the same reinforcement ratio as steel bars. Twenty-four circular concrete columns were tested and categorized into six groups based on the type of reinforcement employed. Each group comprised four columns, with one subjected to concentric axial load, two subjected to eccentric axial load (with eccentricities of 25 mm and 50 mm, respectively), and one tested under lateral flexural loads. To validate the experimental results, finite element (FE) analysis was conducted using ABAQUS software version 6.14. The experimental findings for concentric load reveal that columns with the second type of reinforcement, concrete-filled steel tubes with 30% of the reinforcement ratio of steel bars exhibited a failure load 19% lower than those with steel bars, while columns with the third type of reinforcement, concrete-filled steel tubes with the same reinforcement ratio as steel bars achieved a failure load 17% greater than the traditional steel bars. The FE analysis demonstrates good agreement with the experimental outcomes in terms of ultimate strength, deformation, and failure modes.
引用
收藏
页数:24
相关论文
共 38 条
[1]   Axial Load-Axial Deformation Behaviour of SCC Columns Reinforced with Steel Tubes [J].
Alhussainy, Faez ;
Sheikh, M. Neaz ;
Hadi, Muhammad N. S. .
STRUCTURES, 2018, 15 :259-269
[2]  
Alshimmeri AJH, 2016, J ENG-NY, V22, P125, DOI 10.31026/j.eng.2016.08.08
[3]   Analytical behaviour of eccentrically loaded concrete-encased CFST box columns [J].
An, Yu-Feng ;
Han, Lin-Hai ;
Zhao, Xiao-Ling .
MAGAZINE OF CONCRETE RESEARCH, 2014, 66 (15) :789-808
[4]   Experimental behaviour of box concrete-encased CFST eccentrically loaded column [J].
An, Yu-Feng ;
Han, Lin-Hai ;
Zhao, Xiao-Ling .
MAGAZINE OF CONCRETE RESEARCH, 2013, 65 (20) :1219-1235
[5]  
[Anonymous], 2017, Standard test method for Microindentation Hardness of Materials, in, P1
[6]  
[Anonymous], 2010, ASTM STAND B, VC78-02, P1, DOI [DOI 10.1520/C0078_C0078M-22, 10.1520/C0078, DOI 10.1520/C0078]
[7]  
[Anonymous], 2018, ASTM C39-18
[8]  
[Anonymous], 2020, Standard Specifications for Testing Methods and Definition for Mechanical Testing Steel Products, P248
[9]  
[Anonymous], 2018, ASTM A370
[10]  
[Anonymous], 2014, Building code requirements for structural concrete (ACI 318-14)