Evaluation of compression self-healing performance of a smart cementitious composite SMA-ECC

被引:7
作者
Chen, Weihong [1 ]
Han, Chunhui [1 ]
Xie, Yunjun [1 ]
Lin, Boxu [1 ]
Cui, Shuangshuang [2 ]
机构
[1] Fuzhou Univ, Coll Civil Engn, Fuzhou 350108, Peoples R China
[2] Fujian Univ Technol, Coll Civil Engn, Fuzhou 350118, Peoples R China
关键词
SMA-ECC; SMA fiber content; Preloading level; Self-healing; Compressive state; SHAPE-MEMORY ALLOY; BRITTLE-FRACTURE; CONCRETE; KINETICS; BEHAVIOR; FIBERS; AGENTS; CRACKS; NITI; UREA;
D O I
10.1016/j.conbuildmat.2023.133917
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A two-stage compressive test was adopted to study the self-healing performance of a smart cementitious composite SMA-ECC under compression. The ultrasonic pulse and sorptivity tests were used to track self-healing ability and resistance to internal damage, respectively. A total of 32 groups of specimens, including 28 groups of SMA-ECC specimens and 4 groups of ordinary ECC specimens, were tested with various fiber contents and preloading levels. The strength recovery rate, relative dynamic elastic modulus recovery rate before and after self-healing, and cumulative water absorption were measured during the tests. It was found that the strength recovery rate of the SMA-ECC increased by 29.2% to 37.2% compared to the ordinary ECC. The elastic modulus recovery rate after self-healing of the SMA-ECC is approximately 3 to 10 times that of the ordinary ECC, and SMA-ECC with a 0.9% fiber content exhibits the best healing effect, with a remarkable 194% increase in elastic modulus recovery rate compared to ECC. As for internal damage, an increase in fiber content corresponds to a decrease in relative sorptivity coefficient (eta) in most cases. Notably, for SMA-ECC specimens featuring a 0.9% fiber content, eta reaches its nadir, hovering around 0.7. The situation takes an unexpected turn when fiber content hits 1%, as the relative sorptivity coefficient experiences a 14.9% increment compared to the SMA-ECC with 0.9% fiber content. Based on the test results, it is concluded that the SMA-ECC has excellent compressive recovery performance and the ability to resist internal damage. The optimal SMA fiber content for the self-healing performance of the SMA-ECC is determined to be 0.7% to 0.9%.
引用
收藏
页数:12
相关论文
共 75 条
[1]   Ultra-high-performance fiber-reinforced concrete. Part V: Mixture design, preparation, mixing, casting, and curing [J].
Akeed, Mahmoud H. ;
Qaidi, Shaker ;
Ahmed, Hemn U. ;
Faraj, Rabar H. ;
Majeed, Samadar S. ;
Mohammed, Ahmed S. ;
Emad, Wael ;
Tayeh, Bassam A. ;
Azevedo, Afonso R. G. .
CASE STUDIES IN CONSTRUCTION MATERIALS, 2022, 17
[2]   Analytical prediction of the seismic behaviour of superelastic shape memory alloy reinforced concrete elements [J].
Alam, M. S. ;
Youssef, M. A. ;
Nehdi, M. .
ENGINEERING STRUCTURES, 2008, 30 (12) :3399-3411
[3]   Simplified modeling of cracking in concrete: Application in tunnel linings [J].
Amorim, David L. N. de F. ;
Proenca, Sergio P. B. ;
Florez-Lopez, Julio .
ENGINEERING STRUCTURES, 2014, 70 :23-35
[4]  
[Anonymous], 2022, ASTM C469/C469M-22
[5]  
[Anonymous], 2009, Standard for Test Methods of Fiber Reinforced Concrete
[6]  
[Anonymous], 2000, CECS 21-2000
[7]   The effect of NiTi shape memory alloy, polypropylene and steel fibres on the fresh and mechanical properties of self-compacting concrete [J].
Aslani, Farhad ;
Liu, Yinong ;
Wang, Yu .
CONSTRUCTION AND BUILDING MATERIALS, 2019, 215 :644-659
[8]  
astm, C1585 STAND TEST MET
[9]   Experimental and analytical investigation of continuous RC beams strengthened by SMA strands under cyclic loading [J].
Azadpour, F. ;
Maghsoudi, A. A. .
CONSTRUCTION AND BUILDING MATERIALS, 2020, 239
[10]   Assessing the natural-healing behavior of adhesively bonded structures under dynamic loading [J].
Brandtner-Hafner, M. H. .
ENGINEERING STRUCTURES, 2019, 196