Dot Product of Confocal Images for Portable Radar-Based Microwave Imaging

被引:2
作者
Song, Hang [1 ,6 ]
Sasada, Shinsuke [2 ,3 ]
Okada, Morihito [3 ]
Arihiro, Koji [4 ]
Xiao, Xia [5 ]
Ishikawa, Tomomi [6 ]
Kikkawa, Takamaro [6 ]
机构
[1] Tokyo Inst Technol, Dept Transdisciplinary Sci & Engn, Tokyo, Japan
[2] Hiroshima Univ Hosp, Dept Breast Surg, Hiroshima, Japan
[3] Hiroshima Univ, Res Inst Radiat Biol & Med, Hiroshima, Japan
[4] Hiroshima Univ Hosp, Dept Anat Pathol, Hiroshima, Japan
[5] Tianjin Univ, Sch Microelect, Tianjin, Peoples R China
[6] Hiroshima Univ, Res Inst Nanodevices, Higashihiroshima, Japan
来源
2023 17TH EUROPEAN CONFERENCE ON ANTENNAS AND PROPAGATION, EUCAP | 2023年
关键词
microwave imaging; breast tumor; confocal imaging; radar-based imaging; BREAST-CANCER DETECTION; DIELECTRIC-PROPERTIES; LARGE-SCALE;
D O I
10.23919/EuCAP57121.2023.10133116
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Objective: The purpose of this study is to develop accurate radar-based microwave imaging. Method: A portable radar-based detector is placed on an excised breast tissue of total mastectomy. Measurements are conducted twice with different orientations for the breast. A two-stage rotational clutter suppression (TSR) algorithm is carried out for the multi-static rotational configuration of the radar-detector. It consists of a signal selection and an adaptive filtering. Dot product is carried out for the two sets of confocal images measured at different orientations to remove clutters. Conclusion: The dot product of two confocal images with different orientations can reconstruct more accurate images than conventional confocal images. It can improve not only image contrast but also the accuracy of tumor location.
引用
收藏
页数:4
相关论文
共 20 条
[1]   Microwave Breast Imaging With a Monostatic Radar-Based System: A Study of Application to Patients [J].
Fear, E. C. ;
Bourqui, J. ;
Curtis, C. ;
Mew, D. ;
Docktor, B. ;
Romano, C. .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2013, 61 (05) :2119-2128
[2]   Confocal microwave Imaging for breast cancer detection: Localization of tumors in three dimensions [J].
Fear, EC ;
Li, X ;
Hagness, SC ;
Stuchly, MA .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2002, 49 (08) :812-822
[3]   CMOS Gaussian Monocycle Pulse Transceiver for Radar-Based Microwave Imaging [J].
Kikkawa, Takamaro ;
Masui, Yoshihiro ;
Toya, Akihiro ;
Ito, Hiroyuki ;
Hirano, Takuichi ;
Maeda, Tomoaki ;
Ono, Masahiro ;
Murasaka, Yoshitaka ;
Imamura, Toshifumi ;
Matsumaru, Tsuyoshi ;
Yamaguchi, Michimasa ;
Sugawara, Mitsutoshi ;
Azhari, Afreen ;
Song, Hang ;
Sasada, Shinsuke ;
Iwata, Atsushi .
IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2020, 14 (06) :1333-1345
[4]   Improved Delay-and-Sum Beamforming Algorithm for Breast Cancer Detection [J].
Klemm, M. ;
Craddock, I. J. ;
Leendertz, J. A. ;
Preece, A. ;
Benjamin, R. .
INTERNATIONAL JOURNAL OF ANTENNAS AND PROPAGATION, 2008, 2008
[5]   A large-scale study of the ultrawideband microwave dielectric properties of normal, benign and malignant breast tissues obtained from cancer surgeries [J].
Lazebnik, Mariya ;
Popovic, Dijana ;
McCartney, Leah ;
Watkins, Cynthia B. ;
Lindstrom, Mary J. ;
Harter, Josephine ;
Sewall, Sarah ;
Ogilvie, Travis ;
Magliocco, Anthony ;
Breslin, Tara M. ;
Temple, Walley ;
Mew, Daphne ;
Booske, John H. ;
Okoniewski, Michal ;
Hagness, Susan C. .
PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (20) :6093-6115
[6]   A large-scale study of the ultrawideband microwave dielectric properties of normal breast tissue obtained from reduction surgeries [J].
Lazebnik, Mariya ;
McCartney, Leah ;
Popovic, Dijana ;
Watkins, Cynthia B. ;
Lindstrom, Mary J. ;
Harter, Josephine ;
Sewall, Sarah ;
Magliocco, Anthony ;
Booske, John H. ;
Okoniewski, Michal ;
Hagness, Susan C. .
PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (10) :2637-2656
[7]   An overview of ultra-wideband microwave imaging via space-time beamforming for early-stage breast-cancer detection [J].
Li, X ;
Bond, EJ ;
Van Veen, BD ;
Hagness, SC .
IEEE ANTENNAS AND PROPAGATION MAGAZINE, 2005, 47 (01) :19-34
[8]   A 4-channel, vector network analyzer microwave imaging prototype based on software defined radio technology [J].
Meaney, Paul ;
Hartov, Alexander ;
Bulumulla, Selaka ;
Raynolds, Timothy ;
Davis, Cynthia ;
Schoenberger, Florian ;
Richter, Sebastian ;
Paulsen, Keith .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2019, 90 (04)
[9]   Microwave imaging for neoadjuvant chemotherapy monitoring: initial clinical experience [J].
Meaney, Paul M. ;
Kaufman, Peter A. ;
Muffly, Lori S. ;
Click, Michael ;
Poplack, Stephen P. ;
Wells, Wendy A. ;
Schwartz, Gary N. ;
di Florio-Alexander, Roberta M. ;
Tosteson, Tor D. ;
Li, Zhongze ;
Geimer, Shireen D. ;
Fanning, Margaret W. ;
Zhou, Tian ;
Epstein, Neil R. ;
Paulsen, Keith D. .
BREAST CANCER RESEARCH, 2013, 15 (02)
[10]   A clinical prototype for active microwave imaging of the breast [J].
Meaney, PM ;
Fanning, MW ;
Li, D ;
Poplack, SP ;
Paulsen, KD .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2000, 48 (11) :1841-1853