Seismic Performance of Precast Shear Wall Systems and Connection Details for Underground Structures

被引:3
作者
Lee, Deuckhang [1 ]
Zhang, Wei [1 ]
Kang, Su-Min [2 ]
Kang, Thomas H. -K. [3 ]
机构
[1] Chungbuk Natl Univ, Dept Architectural Engn, Cheongju 28644, South Korea
[2] Soongsil Univ, Sch Architecture, Seoul 06978, South Korea
[3] Seoul Natl Univ, Dept Architecture & Architectural Engn, Seoul 08826, South Korea
基金
新加坡国家研究基金会;
关键词
Precast; Wall; Seismic performance; Vertical connection; Underground; REINFORCED-CONCRETE BEAMS; POTENTIAL CAPACITY MODEL; BUILDING SYSTEMS; HONG-KONG; DESIGN;
D O I
10.1061/JSENDH.STENG-11888
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Connection details are critical for both seismic performance and constructability of underground precast concrete (PC) shear wall systems. Current traditional wall-to-wall shear connection details present considerable constructability issues. To address this issue, application of cast-in-place (CIP) connecting beams (i.e., cap and waling beams) at the top and midheight of a precast shear wall system was studied. Under the capacity design concept specified in current standards, three test specimens were designed and tested under the reversed cyclic loadings. Of the three, two employed CIP connecting beams. The third, which served as the reference specimen, adopted the traditional ductile connection detail of embedded wire loops. In addition, numerical simulations and corresponding reverse analyses were conducted to identify the effect of wall-to-wall shear connection details on seismic performance of the precast shear wall systems. Although excellent seismic performance can be achieved by using traditional shear connection, satisfactory seismic performance may also be achieved with proper integration of only CIP beams.
引用
收藏
页数:17
相关论文
共 30 条
[1]   Environmental, Social, and Governance Integration into the Business Model: Literature Review and Research Agenda [J].
Aldowaish, Alaa ;
Kokuryo, Jiro ;
Almazyad, Othman ;
Goi, Hoe Chin .
SUSTAINABILITY, 2022, 14 (05)
[2]  
[Anonymous], 2019, ACI 318-19: Building code requirements for structural concrete and commentary, DOI DOI 10.14359/51716937
[3]  
[Anonymous], 2013, ACI Committee 374
[4]  
[Anonymous], 2017, SEISMIC EVALUATION R
[5]  
[Anonymous], 2017, STANDARD TEST METHOD, DOI DOI 10.1520/D3039_D3039M-17
[6]  
ASCE, 2022, ASCE 7
[7]   Comparing carbon emissions of precast and cast-in-situ construction methods - A case study of high-rise private building [J].
Dong, Ya Hong ;
Jaillon, Lara ;
Chu, Peggy ;
Poon, C. S. .
CONSTRUCTION AND BUILDING MATERIALS, 2015, 99 :39-53
[8]   Pushover of hybrid coupled walls. I: Design and modeling [J].
Ei-Tawil, S ;
Kuenzli, CM ;
Hassan, M .
JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2002, 128 (10) :1272-1281
[9]  
FEMA, 2016, RECOMMENDED SEISMIC
[10]   Experimental shear tests of reinforced concrete beams with corroded longitudinal reinforcement [J].
Han, Sun-Jin ;
Lee, Deuckhang ;
Yi, Seong-Tae ;
Kim, Kang Su .
STRUCTURAL CONCRETE, 2020, 21 (05) :1763-1776