Accelerometer-based portable navigation, a faster guide compared to computer-assisted navigation in bilateral total knee arthroplasty-a randomized controlled study

被引:7
|
作者
Swamy, Arun M. [1 ]
Malhotra, Rajesh [1 ]
Digge, Vijaykumar [1 ]
Manhas, Vikrant [1 ]
Gautam, Deepak [1 ]
Srivastava, Deep Narayana [2 ]
机构
[1] All India Inst Med Sci AIIMS, Dept Orthopaed, Room 139,Teaching Block,Ansari Nagar East, New Delhi 110029, India
[2] All India Inst Med Sci AIIMS, Dept Radiodiag, New Delhi 110029, India
关键词
Computer navigation; Accelerometer-based navigation; Total knee arthroplasty; BLOOD-LOSS; REPLACEMENT; OUTCOMES; SYSTEM;
D O I
10.1007/s00167-021-06842-y
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose There are limited studies in the literature comparing the alignment accuracy of the large console, imageless, computer-assisted navigation (CAN) and portable, hand-held, accelerometer-based navigation (ABN) in total knee arthroplasty (TKA). This study was aimed to compare the operative time, blood loss, radiological, clinical and functional outcomes between CAN- and ABN-guided bilateral TKA. Methods From Jan 2016 to Dec 2017, 50 patients who underwent bilateral TKA were randomized to undergo either CAN-guided or ABN-guided TKA. Tourniquet time and blood loss were recorded, and intra-op complications were noted. Post-op radiological outcomes at 2 weeks were compared between the groups. The clinical and functional outcomes using the American Knee Society Scores (KSS) and Oxford Knee Score (OKS) were recorded pre-operatively and post-operatively at 3, 6, 12 months and at the end of the study with a minimum follow-up of 48 months. Results Both groups were well-matched in terms of patient demographic parameters. The mean surgical time per knee was significantly lower in the ABN group (54.5 +/- 5.6 min) compared to the CAN group (61.7 +/- 13.7 min; p < 0.01). Mean blood loss per knee in the ABN group was 592.1 +/- 245.3 mL compared to 682.8 +/- 322.0 in the CAN group (p = 0.11). In the ABN group, the mean post-op mechanical axis was 1.2 +/- 3.2 degrees (vs 1.5 +/- 2.2 degrees in the CAN group, p 0.6), the frontal femoral angle was 88.8 +/- 2.3 degrees (vs 88.8 +/- 1.8 degrees in the CAN group, p 1.0) and frontal tibial angle was 90.1 +/- 1.6 degrees (vs 89.7 +/- 1.1 degrees in the CAN group, p 0.14). At 48 month follow-up, the mean functional KSS in the ABN group was 89.0 +/- 5.7 (vs 88.1 +/- 4.5 in the CAN group, p 0.37) and the mean OKS was 40.5 +/- 2.8 (vs 39.6 +/- 3.2 in the CAN group, p 0.12). Conclusion Portable, hand-held ABN offers alignment accuracy and functional outcomes in TKA similar to that with CAN, with a reduced duration of surgery. There was no advantage of either of the techniques in terms of clinical or functional outcomes at 48 month follow-up.
引用
收藏
页码:786 / 792
页数:7
相关论文
共 50 条
  • [41] Evaluation of accuracy of an electromagnetic computer-assisted navigation system in total knee arthroplasty
    Graydon, A. J.
    Malak, S.
    Anderson, I. A.
    Pitto, R. P.
    INTERNATIONAL ORTHOPAEDICS, 2009, 33 (04) : 975 - 979
  • [42] Evaluation of accuracy of an electromagnetic computer-assisted navigation system in total knee arthroplasty
    A. J. Graydon
    S. Malak
    I. A. Anderson
    R. P. Pitto
    International Orthopaedics, 2009, 33 : 975 - 979
  • [43] Total knee arthroplasty with computer-assisted navigation more closely replicates normal knee biomechanics than conventional surgery
    McClelland, Jodie A.
    Webster, Kate E.
    Ramteke, Alankar A.
    Feller, Julian A.
    KNEE, 2017, 24 (03) : 651 - 656
  • [44] Accelerometer-based navigation vs. conventional techniques for total knee arthroplasty (TKA): a systematic review and meta-analysis of randomized controlled trials
    Juntan Li
    Yuqi Zhang
    Xiang Gao
    Tianxu Dou
    Xu Li
    Arthroplasty, 4
  • [45] Functional outcome after computer-assisted versus conventional total knee arthroplasty: a randomized controlled study
    Luetzner, Joerg
    Guenther, Klaus-Peter
    Kirschner, Stephan
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2010, 18 (10) : 1339 - 1344
  • [46] Accuracy of Accelerometer-Based Navigation System Perseus for the Tibial Cut in Total Knee Arthroplasty: No Superiority Compared to Mechanical Instrumentation in Current Practice
    Joseph, Leopold
    Batailler, Cecile
    Lustig, Sebastien
    Servien, Elvire
    APPLIED SCIENCES-BASEL, 2023, 13 (05):
  • [47] Accelerometer-Based Navigation in Primary Total Knee Arthroplasty Leads to Improved Alignment but No Change in Patient-Reported Outcomes
    Treu, Emily A.
    Frandsen, Jeffrey J.
    Woodley, Cullen D.
    Loughmiller, Shanna K.
    Blackburn, Brenna E.
    Peters, Christopher L.
    JOURNAL OF ARTHROPLASTY, 2023, 38 (06) : S222 - S226
  • [48] Does the accelerometer-based navigation system reduce blood loss and transfusion in one-stage sequential bilateral total knee arthroplasty? A randomized double-blind controlled trial
    Atthakorn Jarusriwanna
    Chaturong Pornrattanamaneewong
    Rapeepat Narkbunnam
    Pakpoom Ruangsomboon
    Paweena Thitithapana
    Keerati Chareancholvanich
    BMC Musculoskeletal Disorders, 24
  • [49] Computer-Assisted Navigation System Helps Experienced Surgeon Improve Outcome in Total Knee Arthroplasty
    Wong, To
    Chen, Sung-Hsiung
    Ko, Jih-Yang
    Wang, Feng-Sheng
    Chou, Wen-Yi
    Chen, June-Ming
    LIFE SCIENCE JOURNAL-ACTA ZHENGZHOU UNIVERSITY OVERSEAS EDITION, 2012, 9 (02): : 185 - 190
  • [50] Improved implant alignment accuracy with an accelerometer-based portable navigation system in medial unicompartmental knee arthroplasty
    Suda, Yoshihito
    Takayama, Koji
    Ishida, Kazunari
    Hayashi, Shinya
    Hashimoto, Shingo
    Niikura, Takahiro
    Matsushita, Takehiko
    Kuroda, Ryosuke
    Matsumoto, Tomoyuki
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2020, 28 (09) : 2917 - 2923