Ninety-Hz Spinal Cord Stimulation-Induced Analgesia Is Dependent on Active Charge Balance and Is Nonlinearly Related to Amplitude: A Sham-Controlled Behavioral Study in a Rodent Model of Chronic Neuropathic Pain

被引:4
作者
Heijmans, Lonne [1 ,2 ,3 ]
Zhang, Tianhe C. [4 ]
Esteller, Rosana [4 ]
Joosten, Elbert A. [2 ,3 ]
机构
[1] Univ Singel 50, NL-6229 ER Maastricht, Netherlands
[2] Maastricht Univ Med Ctr, Dept Anesthesiol & Pain Med, Maastricht, Netherlands
[3] Maastricht Univ, Sch Mental Hlth & Neurosci, Dept Translat Neurosci, Maastricht, Netherlands
[4] Boston Sci Neuromodulat Res & Adv Concepts Team, Valencia, CA USA
来源
NEUROMODULATION | 2024年 / 27卷 / 01期
关键词
Energy delivery; FAST-SCS; neuropathic pain; paresthesia-free; spinal cord stimulation; KILOHERTZ-FREQUENCY; RAT MODEL; MECHANICAL HYPERSENSITIVITY; PARAMETERS; INHIBITION; EFFICACY; BACK;
D O I
10.1016/j.neurom.2023.09.005
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background: Ninety-Hz active-recharge spinal cord stimulation (SCS) applied at below sensory-threshold intensity, as used with fast-acting subperception therapy spinal cord stimulation, has been shown clinically to produce significant analgesia, but additional characterization is required to better understand the therapy. This preclinical study investigates the behavioral effect of multiple 90-Hz SCS variants in a rodent model of neuropathic pain, focusing on charge balance and the relationship between 90-Hz efficacy and stimulation intensity. Materials and Methods: Rats (n = 24) received a unilateral partial sciatic nerve ligation to induce neuropathic pain and were implanted with a quadripolar lead at T13. Mechanical hypersensitivity was assessed before, during, and after 60 minutes of SCS. After a prescreen with 50-Hz SCS 67% motor threshold ([MT], the positive control), rats underwent a randomized-crossover study including sham SCS and several 90-Hz SCS paradigms (at 40% MT or 60% MT, either using active or pseudopassive recharge) (experiment 1, n = 16). A second, identical experiment (experiment 2) was performed to supplement data with 90-Hz SCS at 20% and 80% MT (experiment 2, n = 8). Results: Experiment 1: At 40% MT, 90-Hz active-recharge SCS produced a significantly larger recovery to baseline than did 90-Hz pseudopassive SCS at both tested intensities and sham SCS. Experiment 2: Only the 90-Hz SCS active recharge at 40% MT and 50Hz SCS positive control caused mean recovery to baseline that was statistically better than that of sham SCS. Conclusions: The degree to which 90-Hz SCS reduced mechanical hypersensitivity during stimulation depended on the nature of charge balance, with 90-Hz active-recharge SCS generating better responses than did 90-Hz pseudopassive recharge SCS. In addition, our findings suggest that the amplitude of 90-Hz active-recharge SCS must be carefully configured for efficacy.
引用
收藏
页码:95 / 107
页数:13
相关论文
共 32 条
[1]   Fiber Threshold Accommodation as a Mechanism of Burst and High-Frequency Spinal Cord Stimulation [J].
Arle, Jeffrey E. ;
Mei, Longzhi ;
Carlson, Kristen W. .
NEUROMODULATION, 2019, :582-593
[2]   QUANTITATIVE ASSESSMENT OF TACTILE ALLODYNIA IN THE RAT PAW [J].
CHAPLAN, SR ;
BACH, FW ;
POGREL, JW ;
CHUNG, JM ;
YAKSH, TL .
JOURNAL OF NEUROSCIENCE METHODS, 1994, 53 (01) :55-63
[3]   All bursts are equal, but some are more equal (to burst firing): burstDR stimulation versus Boston burst stimulation [J].
De Ridder, Dirk ;
Vancamp, Tim ;
Falowski, Steven M. ;
Vanneste, Sven .
EXPERT REVIEW OF MEDICAL DEVICES, 2020, 17 (04) :289-295
[4]   Success Using Neuromodulation With BURST (SUNBURST) Study: Results From a Prospective, Randomized Controlled Trial Using a Novel Burst Waveform [J].
Deer, Timothy ;
Slavin, Konstantin V. ;
Amirdelfan, Kasra ;
North, Richard B. ;
Burton, Allen W. ;
Yearwood, Thomas L. ;
Tavel, Ed ;
Staats, Peter ;
Falowski, Steven ;
Pope, Jason ;
Justiz, Rafael ;
Fabi, Alain Y. ;
Taghva, Alexander ;
Paicius, Richard ;
Houden, Timothy ;
Wilson, Derron .
NEUROMODULATION, 2018, 21 (01) :56-66
[5]   Time-dynamic pulse modulation of spinal cord stimulation reduces mechanical hypersensitivity and spontaneous pain in rats [J].
Edhi, Muhammad M. ;
Heijmans, Lonne ;
Vanent, Kevin N. ;
Bloye, Kiernan ;
Baanante, Amanda ;
Jeong, Ki-Soo ;
Leung, Jason ;
Zhu, Changfang ;
Esteller, Rosana ;
Saab, Carl Y. .
SCIENTIFIC REPORTS, 2020, 10 (01)
[6]   Fundamental Differences in Burst Stimulation Waveform Design: Eliminating Confusion in the Marketplace [J].
Falowski, Steven M. .
NEUROMODULATION, 2018, 21 (03) :320-320
[7]   Nonlinear Relation Between Burst Dorsal Root Ganglion Stimulation Amplitude and Behavioral Outcome in an Experimental Model of Painful Diabetic Peripheral Neuropathy [J].
Franken, Glenn ;
Debets, Jacques ;
Joosten, Elbert A. J. .
NEUROMODULATION, 2020, 23 (02) :158-166
[8]   Surround Inhibition Mediates Pain Relief by Low Amplitude Spinal Cord Stimulation: Modeling and Measurement [J].
Gilbert, John E. ;
Titus, Nathan ;
Zhang, Tianhe ;
Esteller, Rosana ;
Grill, Warren M. .
ENEURO, 2022, 9 (05)
[9]   THE EFFECT OF STIMULUS PARAMETERS ON THE RECRUITMENT CHARACTERISTICS OF DIRECT NERVE-STIMULATION [J].
GORMAN, PH ;
MORTIMER, JT .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1983, 30 (07) :407-414
[10]   Novel 10-kHz High-frequency Therapy (HF10 Therapy) Is Superior to Traditional Low-frequency Spinal Cord Stimulation for the Treatment of Chronic Back and Leg Pain [J].
Kapural, Leonardo ;
Yu, Cong ;
Doust, Matthew W. ;
Gliner, Bradford E. ;
Vallejo, Ricardo ;
Sitzman, B. Todd ;
Amirdelfan, Kasra ;
Morgan, Donna M. ;
Brown, Lora L. ;
Yearwood, Thomas L. ;
Bundschu, Richard ;
Burton, Allen W. ;
Yang, Thomas ;
Benyamin, Ramsin ;
Burgher, Abram H. .
ANESTHESIOLOGY, 2015, 123 (04) :851-860