Risk of anastomotic leakage with two-row versus three-row manual circular staplers in colorectal anastomosis: a US cohort study

被引:5
作者
Wang, Tongtong [1 ]
Sadowsky, Mordechai [2 ]
Blakney, Rebekah [1 ]
Coplan, Paul [1 ]
Petraiuolo, William [2 ]
Soberman, Mark [2 ]
Tomaszewski, Joerg [3 ]
Rene, Lexi [1 ]
Wood, Jennifer [1 ]
机构
[1] Johnson & Johnson, Epidemiol & Real World Data Sci, MedTech, New Brunswick, NJ 08933 USA
[2] Johnson & Johnson, Med Safety, MedTech, New Brunswick, NJ USA
[3] Johnson & Johnson, Med Affairs, MedTech, Raritan, NJ USA
关键词
Anastomotic leak; Manual circular staplers; Left-sided colorectal surgery; Retrospective cohort study; Premier Healthcare Database (PHD); ANTERIOR RESECTION; RECTAL-CANCER; SURGERY; MORBIDITY; MORTALITY; DESIGN;
D O I
10.1007/s00384-023-04552-0
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
PurposesTo compare the risk of anastomotic leak (AL) between Ethicon manual circular staplers (two-row) versus Medtronic EEA (TM) circular stapler with Tri-Staple (TM) technology (three-row) and between Medtronic EEA (TM) circular stapler with DST (TM) Series technology (two-row) versus Tri-Staple (TM) technology.MethodsA retrospective cohort study was conducted in adult patients who underwent a left-sided colorectal surgery 2019-2022 in U.S. Premier Healthcare Database to assess the risk of AL within 30 days post-index procedure. The study devices were Ethicon manual circular staplers, Medtronic EEA (TM) circular stapler with DST (TM) technology, and Medtronic EEA (TM) circular stapler with Tri-Staple (TM) technology.ResultsAcross 447 hospitals, the cumulative incidences (95% confidence intervals [CI]) of AL within 30 days post-index procedure were 7.78% (6.91-8.74%) among 8337 patients in the Ethicon manual circular stapler cohort, 7.54% (6.87-8.27%) among 7928 patients in the Medtronic EEA (TM) circular stapler with DST (TM) technology cohort, and 8.19% (6.57-10.07%) among 1306 patients in the Medtronic EEA (TM) circular stapler with Tri-Staple (TM) technology cohort. Comparative analyses revealed no difference comparing Ethicon manual circular staplers with Medtronic EEA (TM) circular staplers with Tri-Staple (TM) technology (risk ratio [RR], 0.72; 95% CI, 0.52-1.01) or comparing Medtronic EEA (TM) circular staplers with DST (TM) technology to Tri-Staple (TM) technology (RR, 0.75; 95% CI, 0.53-1.06).ConclusionIn this analysis of a large cohort of patients undergoing a left-sided colorectal surgery from a U.S. hospital database, the risk of AL observed with manual two-row circular staplers was similar to that seen with three-row devices. This study affirms the safety of manual two-row circular staplers in colorectal anastomosis.
引用
收藏
页数:16
相关论文
共 29 条
  • [1] The economic impact of anastomotic leakage after anterior resections in English NHS hospitals: are we adequately remunerating them?
    Ashraf, S. Q.
    Burns, E. M.
    Jani, A.
    Altman, S.
    Young, J. D.
    Cunningham, C.
    Faiz, O.
    Mortensen, N. J.
    [J]. COLORECTAL DISEASE, 2013, 15 (04) : E190 - E198
  • [2] Anastomotic leaks after anterior resection for mid and low rectal cancer: survey of the Italian Society of Colorectal Surgery
    Asteria, C. R.
    Gagliardi, G.
    Pucciarelli, S.
    Romano, G.
    Infantino, A.
    La Torre, F.
    Tonelli, F.
    Martin, F.
    Pulica, C.
    Ripetti, V.
    Diana, G.
    Amicucci, G.
    Carlini, M.
    Sommariva, A.
    Vinciguerra, G.
    Poddie, D. B.
    Amato, A.
    Bassi, R.
    Galleano, R.
    Veronese, E.
    Mancini, S.
    Pescio, G.
    Occelli, G. L.
    Bracchitta, S.
    Castagnola, M.
    Pontillo, T.
    Cimmino, G.
    Prati, U.
    Vincenti, R.
    [J]. TECHNIQUES IN COLOPROCTOLOGY, 2008, 12 (02) : 103 - 110
  • [3] Systematic review of the definition and measurement of anastomotic leak after gastrointestinal surgery
    Bruce, J
    Krukowski, ZH
    Al-Khairy, G
    Russell, EM
    Park, KGM
    [J]. BRITISH JOURNAL OF SURGERY, 2001, 88 (09) : 1157 - 1168
  • [4] CAFRI G., 2018, Obs. Stud., V4, P292, DOI [10.1353/obs.2018.0009, DOI 10.1353/OBS.2018.0009]
  • [5] Catarci M, 2023, Int J Surg.Publish Ahead of Print
  • [6] Cheregi Cornel Dragos, 2017, Clujul Med, V90, P305, DOI 10.15386/cjmed-787
  • [7] Anastomotic leakage in colorectal cancer surgery
    Chiarello, Maria Michela
    Fransvea, Pietro
    Cariati, Maria
    Adams, Neill James
    Bianchi, Valentina
    Brisinda, Giuseppe
    [J]. SURGICAL ONCOLOGY-OXFORD, 2022, 40
  • [8] Prospective trial evaluating new circular and linear stapler devices for gastrointestinal anastomosis: preliminary data
    De Nardi, P.
    Panzeri, F.
    Staudacher, C.
    [J]. TECHNIQUES IN COLOPROCTOLOGY, 2008, 12 (01) : 69 - 72
  • [9] Risk factors for anastomotic leak and postoperative morbidity and mortality after elective right colectomy for cancer: results from a prospective, multicentric study of 1102 patients
    Frasson, Matteo
    Granero-Castro, Pablo
    Ramos Rodriguez, Jose Luis
    Flor-Lorente, Blas
    Braithwaite, Mariela
    Marti Martinez, Eva
    Alvarez Perez, Jose Antonio
    Codina Cazador, Antonio
    Espi, Alejandro
    Garcia-Granero, Eduardo
    [J]. INTERNATIONAL JOURNAL OF COLORECTAL DISEASE, 2016, 31 (01) : 105 - 114
  • [10] Anastomotic leakage after resection of colorectal cancer generates prodigious use of hospital resources
    Frye, J.
    Bokey, E. L.
    Chapuis, P. H.
    Sinclair, G.
    Dent, O. F.
    [J]. COLORECTAL DISEASE, 2009, 11 (09) : 917 - 920