Numerical investigation of the effects of inlet conditions and wall heat transfer on subcritical/transcritical CO2 nozzle performance

被引:7
作者
Zhang, ZiXuan [1 ,2 ,3 ]
Lu, Zhaijun [1 ,2 ,3 ]
Wang, Jiaqiang [1 ,2 ,3 ]
Liu, Dongrun [1 ,2 ,3 ]
Fan, Dengke [1 ,2 ,3 ]
Yao, Shujian [1 ,2 ,3 ]
机构
[1] Cent South Univ, Sch Traff & Transportat Engn, Key Lab Traff Safety Track, Minist Educ, Changsha 410075, Peoples R China
[2] Joint Int Res Lab Key Technol Rail Traff Safety, Changsha 410075, Peoples R China
[3] Cent South Univ, Natl & Local Joint Engn Res Ctr Safety Technol Rai, Sch Traff & Transportat Engn, Changsha 410075, Peoples R China
基金
中国国家自然科学基金;
关键词
Non-equilibrium flash phase transition; Inlet vapour-liquid equilibrium flow; Wall heat transfer; Supercool; Exergy and entropy generation analysis; REFRIGERATION SYSTEMS; VOID FRACTION; EJECTOR; FLOW; EQUATION; MODEL; GAS; SIMULATION; STATE;
D O I
10.1016/j.ijthermalsci.2023.108505
中图分类号
O414.1 [热力学];
学科分类号
摘要
In ejector-based refrigeration cycles and CO2 heat pump cycles, inlet flow state and wall heat transfer play an important role in improving nozzle performance. A CO2 two-phase nozzle model was firstly established. Then, the numerical model is validated by experimental data and void fraction correlation, and the effect of condensation coefficient and gas equation of state was analyzed. In addition, the CO2 flow behavior and the thermodynamic performance of the nozzle under different inlet gas phase volume fraction (GVF) and wall conditions (temperature and materials) were studied. The results show that although the GVF can reduce the critical mass flow rate of the nozzle, its adverse impact on the thermodynamic performance of the nozzle is more significant (The GVF varied from 0 to 0.6, with the former decreasing by 10.2% and the latter increasing by 25.1%). Low temperature on the wall will exacerbate the non-equilibrium phase transition, leading to an increase in the critical mass flow rate of the nozzle. At this time, high thermal conductivity walls will also exacerbate exergy losses, by using low thermal conductivity walls can improve the consequences. In addition, the study also found that the inlet supercooling degree (ISCD) should be set between 0 and 7 K, and excessive ISCD would lead to an increase in outlet humidity and a rise in critical mass flow.
引用
收藏
页数:22
相关论文
共 58 条
[1]   Performance comparison of different supercritical carbon dioxide Brayton cycles integrated with a solar power tower [J].
Al-Sulaiman, Fahad A. ;
Atif, Maimoon .
ENERGY, 2015, 82 :61-71
[2]   Investigating the effect of water nano-droplets injection into the convergent-divergent nozzle inlet on the wet steam flow using entropy generation analysis [J].
Aliabadi, Mohammad Ali Faghih ;
Jahangiri, Ali ;
Khazaee, Iman ;
Lakzian, Esmail .
INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2020, 149
[3]   Development of Delayed Equilibrium Model for CO2 convergent-divergent nozzle transonic flashing flow [J].
Angielczyk, Wojciech ;
Bartosiewicz, Yann ;
Butrymowicz, Dariusz .
INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 2020, 131
[4]   Prediction of critical mass rate of flashing carbon dioxide flow in convergent-divergent nozzle [J].
Angielczyk, Wojciech ;
Seynhaeve, Jean Marie ;
Gagan, Jerzy ;
Bartosiewicz, Yann ;
Butrymowicz, Dariusz .
CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2019, 143
[5]  
AUNGIER RH, 1995, J FLUID ENG-T ASME, V117, P277, DOI 10.1115/1.2817141
[6]   Transcritical carbon dioxide heat pump systems: A review [J].
Austin, Brian T. ;
Sumathy, K. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2011, 15 (08) :4013-4029
[7]   Numerical study of high-speed two-phase ejector performance with R134a refrigerant [J].
Baek, Sunghoon ;
Ko, Seungbin ;
Song, Simon ;
Ryu, Sungmin .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2018, 126 :1071-1082
[8]  
Brennen C.E., 2005, FUNDAMENTALS MULTIPH
[9]   Turbulence modeling of a single-phase R134a supersonic ejector. Part 2: Local flow structure and exergy analysis [J].
Croquer, S. ;
Poncet, S. ;
Aidoun, Z. .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2016, 61 :153-165
[10]   Comparison of ejector predicted performance by thermodynamic and CFD models [J].
Croquer, Sergio ;
Poncet, Sebastien ;
Galanis, Nicolas .
INTERNATIONAL JOURNAL OF REFRIGERATION, 2016, 68 :28-36