Do-it-yourself continuous glucose monitoring in people aged 16 to 69 years with type 1 diabetes: A qualitative study

被引:1
|
作者
Sehgal, Shekhar [1 ]
Boucsein, Alisa [1 ]
Styles, Sara [2 ]
Palmer, Octavia [1 ]
Paul, Ryan G. [3 ]
Crocket, Hamish [3 ]
de Bock, Martin [4 ,5 ]
Wheeler, Benjamin J. [1 ,6 ]
机构
[1] Univ Otago, Dunedin Sch Med, Dept Womens & Childrens Hlth, Dunedin, New Zealand
[2] Univ Otago, Dept Human Nutr, Div Sci, Dunedin, New Zealand
[3] Univ Waikato, Te Huataki Waiora Sch Hlth, Hamilton, New Zealand
[4] Univ Otago, Dept Paediat, Christchurch, New Zealand
[5] Te Whatu Ora Waitaha Canterbury, Dept Paediat, Canterbury, New Zealand
[6] Te Whatu Ora Southern, Dept Paediat, Dunedin, New Zealand
关键词
continuous glucose monitoring; do-it-yourself; glycaemic control; qualitative; type; 1; diabetes; CHILDREN; ADULTS;
D O I
10.1111/dme.15168
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: In many countries, real-time continuous glucose monitoring (rt-CGM) is not funded, and cost presents a barrier to access. A do-it-yourself conversion of intermittently scanned CGM (DIY-CGM) is a cheaper alternative. This qualitative study aimed to explore user experiences with DIY-CGM in people aged 16 to 69 years with type 1 diabetes (T1D). Methods: Convenience sampling was used to recruit participants for semi-structured virtual interviews exploring experiences of DIY-CGM use. Participants were recruited after completing the intervention arm of a crossover randomised controlled trial that evaluated DIY-CGM versus intermittently scanned CGM (isCGM). Participants were previously naive to DIY-CGM and rt-CGM but not isCGM. The DIY-CGM intervention consisted of a Bluetooth bridge connected to isCGM, adding rt-CGM functionality over 8 weeks. Interviews were transcribed, then thematic analysis was performed. Results: Interviews were with 12 people aged 16 to 65 years, with T1D: mean age +/- SD 43 +/- 14 years; baseline mean HbA1c +/- SD 60 mmol/mol +/- 9.9 (7.6 +/- 0.9%) and time in range 59.8% +/- 14.8%. Participants perceived that using DIY- -CGM improved both glycaemic control and aspects of quality of life. Alarm and trend functionality allowed participants to perceive reduced glycaemic variability overnight and following meals. The addition of a smartwatch increased discrete access to glucose information. There was a high degree of trust in DIY-CGM. Challenges while using DIY-CGM included signal loss during vigorous exercise, alarm fatigue and short battery life. Conclusions: This study suggests that for users, DIY- -CGM appears to be an acceptable alternative method of rt-CGM.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Safety and effectiveness of do-it-yourself artificial pancreas system compared with continuous subcutaneous insulin infusions in combination with free style libre in people with type 1 diabetes
    Patel, Rachel
    Crabtree, Thomas S. J.
    Taylor, Nicola
    Langeland, Linn
    Gazis, Anastasios
    Mendis, Buddhike
    Wilmot, Emma G.
    Idris, Iskandar
    DIABETIC MEDICINE, 2022, 39 (05)
  • [22] Performance of intermittently scanned continuous glucose monitoring systems in people with type 1 diabetes: A pooled analysis
    Moser, Othmar
    Sternad, Christoph
    Eckstein, Max L.
    Szadkowska, Agnieszka
    Michalak, Arkadiusz
    Mader, Julia K.
    Ziko, Haris
    Elsayed, Hesham
    Aberer, Felix
    Sola-Gazagnes, Agnes
    Larger, Etienne
    Fadini, Gian Poalo
    Bonora, Benedetta Maria
    Bruttomesso, Daniela
    Boscari, Federico
    Freckmann, Guido
    Pleus, Stefan
    Christiansen, Sverre C.
    Sourij, Harald
    DIABETES OBESITY & METABOLISM, 2022, 24 (03) : 522 - 529
  • [23] The Relation of Diabetes Complications to a New Interpretation of Glycaemic Variability from Continuous Glucose Monitoring in People with Type 1 Diabetes
    Heald, Adrian H.
    Stedman, Mike
    Levy, John Warner
    Belston, Lleyton
    Paisley, Angela
    Patel, Reena
    White, Alison
    Jude, Edward
    Gibson, JMartin
    Habte-Asres, Hellena
    Whyte, Martin
    Forbes, Angus
    DIABETES THERAPY, 2024, 15 (12) : 2489 - 2498
  • [24] Study protocol: glycaemic outcomes in people with type 2 diabetes initiating continuous glucose monitoring: the 2GO-CGM study
    Lever, Claire S.
    Williman, Jonathan A.
    Boucsein, Alisa
    Watson, Antony
    Sampson, Rachael S.
    Sergel-Stringer, Oscar T.
    Keesing, Celeste
    Chepulis, Lynne
    Wheeler, Benjamin J.
    de Bock, Martin I.
    Paul, Ryan G.
    JOURNAL OF DIABETES AND METABOLIC DISORDERS, 2023, 22 (02) : 1779 - 1792
  • [25] Long-Term Effects of Initiating Continuous Subcutaneous Insulin Infusion (CSII) and Continuous Glucose Monitoring (CGM) in People with Type 1 Diabetes and Unsatisfactory Diabetes Control
    Senn, Jon-Duri
    Fischli, Stefan
    Slahor, Lea
    Schelbert, Susanne
    Henzen, Christoph
    JOURNAL OF CLINICAL MEDICINE, 2019, 8 (03)
  • [26] Accuracy of Continuous Glucose Monitoring in People With Type 1 Diabetes Receiving Hemodialysis in Hospital
    Wang, Ray
    Kyi, Mervyn
    Krishnamoorthi, Brintha
    Connell, Ailie
    Chiang, Cherie
    Renouf, Debra
    Barmanray, Rahul
    Dwyer, Karen
    Fourlanos, Spiros
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2025,
  • [27] Continuous glucose monitoring in adults with type 1 diabetes: A balance between benefits and barriers: A critical incident study
    Sorgard, Beate
    Iversen, Marjolein M.
    Martensson, Jan
    JOURNAL OF CLINICAL NURSING, 2019, 28 (17-18) : 3318 - 3329
  • [28] Effect of switch from flash glucose monitoring to flash glucose monitoring with real-time alarms on hypoglycaemia in people with type 1 diabetes mellitus
    Gutierrez-Pastor, A.
    Quesada, J. A.
    Soler-Martinez, M. M.
    Munuera, C. Carratala
    Pomares-Gomez, F. J.
    PRIMARY CARE DIABETES, 2024, 18 (03) : 333 - 339
  • [29] Continuous glucose monitoring use and glucose variability in pre-school children with type 1 diabetes
    Dovc, Klemen
    Cargnelutti, Kevin
    Sturm, Anze
    Selb, Julij
    Bratina, Natasa
    Battelino, Tadej
    DIABETES RESEARCH AND CLINICAL PRACTICE, 2019, 147 : 76 - 80
  • [30] Use of Personal Continuous Glucose Monitoring Device Is Associated With Reduced Risk of Hypoglycemia in a 16-Week Clinical Trial of People With Type 1 Diabetes Using Continuous Subcutaneous Insulin Infusion
    Jensen, Morten Hasselstrom
    Vestergaard, Peter
    Hirsch, Irl B.
    Hejlesen, Ole
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2022, 16 (01): : 106 - 112