Virtual unenhanced dual-energy computed tomography for photon radiotherapy: The effect on dose distribution and cone-beam computed tomography based position verification

被引:3
作者
Afifah, Maryam [1 ,3 ]
Bulthuis, Marloes C. [2 ]
Goudschaal, Karin N. [2 ]
Verbeek-Spijkerman, Jolanda M. [2 ]
Rosario, Tezontl S. [1 ]
den Boer, Duncan [1 ]
Hinnen, Karel A. [2 ]
Bel, Arjan [2 ]
van Kesteren, Zdenko [2 ]
机构
[1] Locat Vrije Univ, Dept Radiat Oncol, Amsterdam UMC, De Boelelaan 1118, Amsterdam, Netherlands
[2] Locat Univ Amsterdam, Dept Radiat Oncol, Amsterdam UMC, Meibergdreef 9, Amsterdam, Netherlands
[3] Amsterdam UMC, locatie VUmc, Boelelaan 1117, NL-1081 HV Amsterdam, Netherlands
关键词
Photon therapy; Dual-energy CT; Virtual unenhanced; Virtual non-contrast; Contrast-enhanced CT; Gynecological irradiation; RADIATION-THERAPY; CONTOURING GUIDELINES; CONTRAST AGENTS; CT IMAGES; REGISTRATION; REDUCTION; ABDOMEN;
D O I
10.1016/j.phro.2024.100545
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and Purpose: Virtual Unenhanced images (VUE) from contrast-enhanced dual-energy computed tomography (DECT) eliminate manual suppression of contrast-enhanced structures (CES) or pre-contrast scans. CT intensity decreases in high-density structures outside the CES following VUE algorithm application. This study assesses VUE's impact on the radiotherapy workflow of gynecological tumors, comparing dose distribution and cone-beam CT-based (CBCT) position verification to contrast-enhanced CT (CECT) images. Materials and Methods: A total of 14 gynecological patients with contrast-enhanced CT simulation were included. Two CT images were reconstructed: CECT and VUE. Volumetric Modulated Arc Therapy (VMAT) plans generated on CECT were recalculated on VUE using both the CECT lookup table (LUT) and a dedicated VUE LUT. Gamma analysis assessed 3D dose distributions. CECT and VUE images were retrospectively registered to daily CBCT using Chamfer matching algorithm.. Results: Planning target volume (PTV) dose agreement with CECT was within 0.35% for D-2%, D-mean, and D-98%. Organs at risk (OARs) D2% agreed within 0.36%. A dedicated VUE LUT lead to smaller dose differences, achieving a 100% gamma pass rate for all subjects. VUE imaging showed similar translations and rotations to CECT, with significant but minor translation differences (<0.02 cm). VUE-based registration outperformed CECT. In 24% of CBCT-CECT registrations, inadequate registration was observed due to contrast-related issues, while corresponding VUE images achieved clinically acceptable registrations. Conclusions: VUE imaging in the radiotherapy workflow is feasible, showing comparable dose distributions and improved CBCT registration results compared to CECT. VUE enables automated bone registration, limiting interobserver variation in the Image-Guided Radiation Therapy (IGRT) process.
引用
收藏
页数:7
相关论文
共 37 条
[1]  
Binjola A, 2020, PRACTICAL RADIATION ONCOLOGY, P3, DOI 10.1007/978-981-15-0073-2_1
[2]   HIERARCHICAL CHAMFER MATCHING - A PARAMETRIC EDGE MATCHING ALGORITHM [J].
BORGEFORS, G .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1988, 10 (06) :849-865
[3]   Comparison of true unenhanced and virtual unenhanced (VUE) attenuation values in abdominopelvic single-source rapid kilovoltage-switching spectral CT [J].
Borhani, Amir A. ;
Kulzer, Matthew ;
Iranpour, Negaur ;
Ghodadra, Anish ;
Sparrow, Mark ;
Furlan, Alessandro ;
Tublin, Mitchell E. .
ABDOMINAL RADIOLOGY, 2017, 42 (03) :710-717
[4]   The Added Value of Virtual Unenhanced Images Obtained From Dual-energy CT Urography in the Detection and Measurement of Urinary Stone [J].
Cheng, Yannan ;
Sun, Jingtao ;
Li, Jianying ;
Han, Yangyang ;
Zhang, Xianghui ;
Zhang, Lu ;
Zheng, Jie ;
He, Hui ;
Yang, Jian ;
Guo, Jianxin .
UROLOGY, 2022, 166 :118-125
[5]   Abdominal rapid-kVp-switching dual-energy MDCT with reduced IV contrast compared to conventional MDCT with standard weight-based IV contrast: an intra-patient comparison [J].
Clark, Zachary E. ;
Bolus, David N. ;
Little, Mark D. ;
Morgan, Desiree E. .
ABDOMINAL IMAGING, 2015, 40 (04) :852-858
[6]   Split-filter dual energy computed tomography radiotherapy: From calibration to image guidance [J].
Edmund, Jens ;
Ronjom, Marianne Feen ;
Felter, Mette van Overeem ;
Maare, Christian ;
Dam, Annica Margrete Juul ;
Tsaggari, Eirini ;
Wohlfahrt, Patrick .
PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2023, 28
[7]   Simultaneously integrated boost (SIB) spares OAR and reduces treatment time in locally advanced cervical cancer [J].
Feng, Christine H. ;
Hasan, Yasmin ;
Kopec, Malgorzata ;
Al-Hallaq, Hania A. .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (05) :76-89
[8]   Pelvic Normal Tissue Contouring Guidelines for Radiation Therapy: A Radiation Therapy Oncology Group Consensus Panel Atlas [J].
Gay, Hiram A. ;
Barthold, H. Joseph ;
O'Meara, Elizabeth ;
Bosch, Walter R. ;
El Naqa, Issam ;
Al-Lozi, Rawan ;
Rosenthal, Seth A. ;
Lawton, Colleen ;
Lee, W. Robert ;
Sandler, Howard ;
Zietman, Anthony ;
Myerson, Robert ;
Dawson, Laura A. ;
Willett, Christopher ;
Kachnic, Lisa A. ;
Jhingran, Anuja ;
Portelance, Lorraine ;
Ryu, Janice ;
Small, William, Jr. ;
Gaffney, David ;
Viswanathan, Akila N. ;
Michalski, Jeff M. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 83 (03) :E353-E362
[9]   Quantitative benchmarking of iodine imaging for two CT spectral imaging technologies: a phantom study [J].
Harsaker, Vanja ;
Jensen, Kristin ;
Andersen, Hilde Kjernlie ;
Martinsen, Anne Catrine .
EUROPEAN RADIOLOGY EXPERIMENTAL, 2021, 5 (01)
[10]   Influence of the contrast agents on treatment planning dose calculations of prostate and rectal cancers [J].
Heydarheydari, Sahel ;
Farshchian, Negin ;
Haghparast, Abbas .
REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2016, 21 (05) :441-446