Geometric distortions in clinical MRI sequences for radiotherapy: insights gained from a multicenter investigation

被引:4
作者
Hasler, Signe Winther [1 ,2 ]
Kallehauge, Jesper Folsted [3 ,4 ]
Hansen, Rasmus Hvass [5 ]
Samsoe, Eva [6 ]
Arp, Dennis Tideman [7 ]
Nissen, Henrik Dahl [8 ]
Edmund, Jens M. [9 ,10 ]
Bernchou, Uffe [1 ,2 ]
Mahmood, Faisal [1 ,2 ]
机构
[1] Odense Univ Hosp, Dept Oncol, Lab Radiat Phys, Klovervaenget 19, DK-5000 Odense, Denmark
[2] Univ Southern Denmark, Dept Clin Res, Odense, Denmark
[3] Aarhus Univ Hosp, Danish Ctr Particle Therapy, Aarhus, Denmark
[4] Aarhus Univ, Dept Clin Med, Aarhus, Denmark
[5] Copenhagen Univ Hosp, Sect Radiat Therapy, Dept Oncol, Ctr Canc & Organ Dis, Copenhagen, Denmark
[6] Zealand Univ Hosp, Dept Clin Oncol, Naestved, Denmark
[7] Aalborg Univ Hosp, Dept Med Phys, Dept Oncol, Aalborg, Denmark
[8] Univ Hosp Southern Denmark, Vejle Hosp, Dept Med Phys, Vejle, Denmark
[9] Herlev & Gentofte Hosp, Dept Oncol, Radiotherapy Res Unit, Herlev, Denmark
[10] Univ Copenhagen, Niels Bohr Inst, Copenhagen, Denmark
关键词
Geometric distortion; radiotherapy; MRI-guided radiation therapy; MRI sequences; magnetic resonance imaging; ECHO-PLANAR IMAGES; RADIATION-THERAPY; SIMULATION; ACCURACY; LINAC;
D O I
10.1080/0284186X.2023.2266560
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
BackgroundAs magnetic resonance imaging (MRI) becomes increasingly integrated into radiotherapy (RT) for enhanced treatment planning and adaptation, the inherent geometric distortion in acquired MR images pose a potential challenge to treatment accuracy. This study aimed to evaluate the geometric distortion levels in the clinical MRI protocols used across Danish RT centers and discuss influence of specific sequence parameters. Based on the variety in geometric performance across centers, we assess if harmonization of MRI sequences is a relevant measure.Materials and methodsNine centers participated with 12 MRI scanners and MRI-Linacs (MRL). Using a travelling phantom approach, a reference MRI sequence was used to assess variation in baseline distortion level between scanners. The phantom was also scanned with local clinical MRI sequences for brain, head/neck (H/N), abdomen, and pelvis. The influence of echo time, receiver bandwidth, image weighting, and 2D/3D acquisition was investigated.ResultsWe found a large variation in geometric accuracy across 93 clinical sequences examined, exceeding the baseline variation found between MRI scanners (sigma = 0.22 mm), except for abdominal sequences where the variation was lower. Brain and abdominal sequences showed lowest distortion levels ([0.22, 2.26] mm), and a large variation in performance was found for H/N and pelvic sequences ([0.19, 4.07] mm). Post hoc analyses revealed that distortion levels decreased with increasing bandwidth and a less clear increase in distortion levels with increasing echo time. 3D MRI sequences had lower distortion levels than 2D (median of 1.10 and 2.10 mm, respectively), and in DWI sequences, the echo-planar imaging read-out resulted in highest distortion levels.ConclusionThere is a large variation in the geometric distortion levels of clinical MRI sequences across Danish RT centers, and between anatomical sites. The large variation observed makes harmonization of MRI sequences across institutions and adoption of practices from well-performing anatomical sites, a relevant measure within RT.
引用
收藏
页码:1551 / 1560
页数:10
相关论文
共 60 条
[1]   How to correct susceptibility distortions in spin-echo echo-planar images: application to diffusion tensor imaging [J].
Andersson, JLR ;
Skare, S ;
Ashburner, J .
NEUROIMAGE, 2003, 20 (02) :870-888
[2]  
[Anonymous], Digital Imaging and Communications in Medicine (DICOM) Standard
[3]   Characterization, prediction, and correction of geometric distortion in 3 T MR images [J].
Baldwin, Lesley N. ;
Wachowicz, Keith ;
Thomas, Steven D. ;
Rivest, Ryan ;
Fallone, B. Gino .
MEDICAL PHYSICS, 2007, 34 (02) :388-399
[4]   A two-step scheme for distortion rectification of magnetic resonance images [J].
Baldwin, Lesley N. ;
Wachowicz, Keith ;
Fallone, B. Gino .
MEDICAL PHYSICS, 2009, 36 (09) :3917-3926
[5]   Field-map correction in read-out segmented echo planar imaging for reduced spatial distortion in prostate DWI for MRI-guided radiotherapy applications [J].
Bergen, Robert, V ;
Ryner, Lawrence ;
Essig, Marco .
MAGNETIC RESONANCE IMAGING, 2020, 67 :43-49
[6]   The effect of respiration-induced target motion on 3D magnetic resonance images used to guide radiotherapy [J].
Bertelsen, Anders ;
Bernchou, Uffe ;
Schytte, Tine ;
Brink, Carsten ;
Mahmood, Faisal .
PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2022, 24 :167-172
[7]   First clinical experiences with a high field 1.5 T MR linac [J].
Bertelsen, Anders S. ;
Schytte, Tine ;
Moller, Pia K. ;
Mahmood, Faisal ;
Riis, Hans L. ;
Gottlieb, Karina L. ;
Agergaard, Soren N. ;
Dysager, Lars ;
Hansen, Olfred ;
Gornitzka, Janne ;
Veldhuizen, Elisabeth ;
ODwyer, Dean B. ;
Christiansen, Rasmus L. ;
Nielsen, Morten ;
Jensen, Henrik R. ;
Brink, Carsten ;
Bernchou, Uffe .
ACTA ONCOLOGICA, 2019, 58 (10) :1352-1357
[8]   Virtual couch shift (VCS): accounting for patient translation and rotation by online IMRT re-optimization [J].
Bol, G. H. ;
Lagendijk, J. J. W. ;
Raaymakers, B. W. .
PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (09) :2989-3000
[9]  
Danish Comprehensive Cancer Center, NAT INT NETW QUAL AS
[10]  
Danziger Z., 2023, THEIL SEN ROBUST LIN