Analysis of the Influence of Grid-Connected Photovoltaic Power Stations with Virtual Inertia on Low-Frequency Oscillation of Power System Based on Small Signal and Prony Analysis Methods

被引:2
作者
Lu, Shengyang [1 ,2 ]
Yan, Zhenhong [2 ]
Zhang, Kaibo [3 ]
Zhu, Yu [2 ]
Yu, Jinbo [3 ]
Wu, Meng [2 ]
Lu, Yan [2 ]
Liu, Dongqi [4 ]
Sui, Yuqiu [1 ]
Yang, Junyou [1 ]
机构
[1] Shenyang Univ Technol, Shenyang 110870, Peoples R China
[2] Elect Power Supply Co Ltd, Elect Power Res Inst State Grid Liaoning, Shenyang 110006, Peoples R China
[3] Shenyang Agr Univ, Shenyang 110866, Peoples R China
[4] NR Elect Co Ltd, 69 Suyuan Ave, Nanjing 211102, Jiangsu, Peoples R China
关键词
Virtual synchronous generator; multi-machine system; low-frequency oscillation; photovoltaic; virtual inertia; small signal; prony;
D O I
10.1142/S0218001423580053
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
With the virtual synchronous generator (VSG) technology gradually becoming an emerging technology for new energy consumption, its introduction has solved the problems of weak support and weak anti-interference of traditional new energy stations. However, the practice shows that the grid-connected characteristics of VSG limit its large-scale utilization, and there is little research on the interaction between VSG and a multi-machine system. In this paper, small signal models and time domain simulation models of each link of a photovoltaic(PV) power station with the PV virtual synchronous generator (PV-VSG) are first conducted, and then the influence of the grid-connected PV power station with the PV-VSG on the low-frequency oscillation of power system and its interaction mechanism with the multi-machine system are qualitatively obtained based on the small signal analysis method and prony analysis method from two dimensions of frequency domain and time domain, respectively. The analysis and simulation show that the PV power station based on VSG technology affects the dynamic characteristics of the system by changing the electromagnetic torque of each synchronous generator. Unreasonable operating conditions and parameter settings will aggravate the phenomenon of low-frequency oscillation of the system. Before the grid connection of PV power station, the operating parameters shall be reasonably set to ensure their safe and stable grid connection.
引用
收藏
页数:29
相关论文
共 28 条
[21]  
Sun D. W., 2018 CHIN INT C EL D, P1938
[22]   Decoupling Scheme for Virtual Synchronous Generator Controlled Wind Farms Participating in Inertial Response [J].
Xi, Jiangbei ;
Geng, Hua ;
Zou, Xin .
JOURNAL OF MODERN POWER SYSTEMS AND CLEAN ENERGY, 2021, 9 (02) :347-355
[23]  
Yan X. W., 2021, Electronics, V10
[24]  
Yang S. M., 2018 OCEANS MTS IEEE
[25]   A Virtual Synchronous Generator Based Hierarchical Control Scheme of Distributed Generation Systems [J].
Yao, Gang ;
Lu, Zhichong ;
Wang, Yide ;
Benbouzid, Mohamed ;
Moreau, Luc .
ENERGIES, 2017, 10 (12)
[26]   Power-frequency oscillation suppression algorithm for AC microgrid with multiple virtual synchronous generators based on fuzzy inference system [J].
Zhang, Liang ;
Zheng, Hao ;
Cai, Guowei ;
Zhang, Zhe ;
Wang, Xuesong ;
Koh, Leong Hai .
IET RENEWABLE POWER GENERATION, 2022, 16 (08) :1589-1601
[27]  
Zhang RX, 2017, IEEE IND ELEC, P1544, DOI 10.1109/IECON.2017.8216262
[28]   Instantaneous power calculation based on intrinsic frequency of single-phase virtual synchronous generator [J].
Zhao, Yangyang ;
Chai, Jianyun ;
Wang, Shien ;
Sun, Kai .
JOURNAL OF MODERN POWER SYSTEMS AND CLEAN ENERGY, 2017, 5 (06) :970-978