Analysis of the Influence of Grid-Connected Photovoltaic Power Stations with Virtual Inertia on Low-Frequency Oscillation of Power System Based on Small Signal and Prony Analysis Methods

被引:1
|
作者
Lu, Shengyang [1 ,2 ]
Yan, Zhenhong [2 ]
Zhang, Kaibo [3 ]
Zhu, Yu [2 ]
Yu, Jinbo [3 ]
Wu, Meng [2 ]
Lu, Yan [2 ]
Liu, Dongqi [4 ]
Sui, Yuqiu [1 ]
Yang, Junyou [1 ]
机构
[1] Shenyang Univ Technol, Shenyang 110870, Peoples R China
[2] Elect Power Supply Co Ltd, Elect Power Res Inst State Grid Liaoning, Shenyang 110006, Peoples R China
[3] Shenyang Agr Univ, Shenyang 110866, Peoples R China
[4] NR Elect Co Ltd, 69 Suyuan Ave, Nanjing 211102, Jiangsu, Peoples R China
关键词
Virtual synchronous generator; multi-machine system; low-frequency oscillation; photovoltaic; virtual inertia; small signal; prony;
D O I
10.1142/S0218001423580053
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
With the virtual synchronous generator (VSG) technology gradually becoming an emerging technology for new energy consumption, its introduction has solved the problems of weak support and weak anti-interference of traditional new energy stations. However, the practice shows that the grid-connected characteristics of VSG limit its large-scale utilization, and there is little research on the interaction between VSG and a multi-machine system. In this paper, small signal models and time domain simulation models of each link of a photovoltaic(PV) power station with the PV virtual synchronous generator (PV-VSG) are first conducted, and then the influence of the grid-connected PV power station with the PV-VSG on the low-frequency oscillation of power system and its interaction mechanism with the multi-machine system are qualitatively obtained based on the small signal analysis method and prony analysis method from two dimensions of frequency domain and time domain, respectively. The analysis and simulation show that the PV power station based on VSG technology affects the dynamic characteristics of the system by changing the electromagnetic torque of each synchronous generator. Unreasonable operating conditions and parameter settings will aggravate the phenomenon of low-frequency oscillation of the system. Before the grid connection of PV power station, the operating parameters shall be reasonably set to ensure their safe and stable grid connection.
引用
收藏
页数:29
相关论文
共 50 条
  • [1] Low-frequency oscillation analysis of two-stage photovoltaic grid-connected system
    Shao, Bingbing
    Miao, Zilong
    Wang, Liyuan
    Meng, Xiaoxiao
    Chen, Zhe
    ENERGY REPORTS, 2022, 8 : 241 - 248
  • [2] Modeling and Low-Frequency Oscillation Analysis of an Asymmetrical Traction Power System Connected to Power Grid
    Chang, Mingyuan
    Wang, Xiaoru
    Lv, Xiaoqin
    Kong, Rui
    IEEE TRANSACTIONS ON TRANSPORTATION ELECTRIFICATION, 2023, 9 (01) : 1750 - 1764
  • [3] Analysis of Forced Low-frequency Oscillation in Single-stage Grid-connected Photovoltaic System Based on Virtual Synchronous Generator Control
    Gong, Zhen
    Shen, Hanming
    Xie, Xiaorong
    Zhang, Zhebo
    Yang, Lei
    Bu, Yichen
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2024, 48 (16): : 18 - 29
  • [4] Eigenvalue Analysis of Subsynchronous Oscillation in Grid-connected PV Power Stations
    Yang, Lin
    Yu, Zhao
    Xu, Tao
    He, Jingbo
    Wang, Chao
    Pang, Chengzong
    PROCEEDINGS OF 2017 CHINA INTERNATIONAL ELECTRICAL AND ENERGY CONFERENCE (CIEEC 2017), 2017, : 285 - 290
  • [5] Design and Analysis of a Grid-Connected Photovoltaic Power System
    Yang, Bo
    Li, Wuhua
    Zhao, Yi
    He, Xiangning
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2010, 25 (04) : 992 - 1000
  • [6] Analysis of the Power Quality of a Grid-Connected Photovoltaic System
    Bandeira, S.
    Vieira, R.
    Guerra, M.
    IEEE LATIN AMERICA TRANSACTIONS, 2020, 18 (04) : 714 - 721
  • [7] Grid-Connected Power Converters with Distributed Virtual Power System Inertia
    Fang, Jingyang
    Li, Xiaoqiang
    Tang, Yi
    2017 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2017, : 4267 - 4273
  • [8] Research on the Influence of Photovoltaic Grid-Connected Power System on Power Grid
    Li, Jian-gang
    Lu, Yong-geng
    Zhang, Zhao-xia
    Li, Bai-yu
    Huang, Yu-ming
    INTERNATIONAL CONFERENCE ON MECHANICAL, ELECTRONIC AND INFORMATION TECHNOLOGY (ICMEIT 2018), 2018, : 84 - 88
  • [9] Analysis of Inertia and Damping Characteristics of Grid-connected Photovoltaic Power Generation System Based on Droop Control
    Wu, Yongbin
    Wang, Sue
    Xiong, Liansong
    Zhang, Donghui
    2019 IEEE 10TH INTERNATIONAL SYMPOSIUM ON POWER ELECTRONICS FOR DISTRIBUTED GENERATION SYSTEMS (PEDG 2019), 2019, : 745 - 750
  • [10] Analysis of Influence of Virtual Synchronous Control on Subsynchronous Oscillation Damping for Grid-connected Wind Power System
    Liu Z.
    Luo J.
    Liang N.
    Han J.
    Yu C.
    Liu J.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2023, 47 (01): : 135 - 142