A Monocentric Randomized Controlled Clinical Trial to Compare Single- and Double-Lumen Needles in Oocyte Retrieval Procedure in Assisted Reproductive Technologies

被引:1
|
作者
Ronchetti, Camilla [1 ,2 ]
Cirillo, Federico [1 ,2 ]
Immediata, Valentina [1 ,2 ]
Gargasole, Clara [1 ]
Scolaro, Valeria [1 ]
Morenghi, Emanuela [2 ,3 ]
Albani, Elena [1 ]
Patrizio, Pasquale [4 ]
Levi-Setti, Paolo Emanuele [1 ,2 ]
机构
[1] IRCCS Humanitas Res Hosp, Fertil Ctr, Dept Gynecol, Div Gynecol & Reprod Med, Via Manzoni 56, I-20089 Milan, Italy
[2] Humanitas Univ, Dept Biomed Sci, Via Rita Levi Montalcini 4, I-20090 Milan, Italy
[3] IRCCS Humanitas Res Hosp, Biostat Unit, Via Manzoni 56, I-20089 Milan, Italy
[4] Univ Miami, Miller Sch Med, Div Reprod Endocrinol & Infertil, Miami, FL USA
关键词
Oocyte retrieval; Flushing; Needle; Single-lumen; Double-lumen; LIVE BIRTH; IVF;
D O I
10.1007/s43032-023-01232-w
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
The purpose was to determine any difference in outcomes, primarily in terms of number of retrieved oocytes per procedure, between two different needles used for oocytes retrieval procedure in Assisted Reproductive Technologies: the single-lumen needle (SLN) versus the double-lumen needle (DLN) with follicle flushing after aspiration. This randomized controlled trial included oocyte retrieval (OR) cycles for IVF and ICSI performed in 18 to 42-year-old women between March 2019 and January 2021 at a tertiary-care Fertility Center. A total of 200 ORs were randomized, 100 in each group. The mean number of retrieved oocytes was not different between groups (10.2 +/- 6.5 for DLNs vs. 10.7 +/- 7.0 for SLNs, p = 0.810). No significant differences were observed also in terms of number of retrieved oocytes/punctured follicles (83.0% +/- 27.0% vs. 81.0% +/- 22.0%, p = 0.916), number of retrieved oocytes/follicles at trigger (78.0% +/- 29.0% vs. 78.0% +/- 27.0%, p = 0.881), number of mature oocytes (7.6 +/- 5.3 vs. 8.0 +/- 5.1, p = 0.519), and pregnancy rate (27% vs. 23%, p = 0.514). However, the time required to retrieve each oocyte was longer using the DLN (1.5 +/- 1.3 vs. 1.1 +/- 0.9 minutes, p = 0.002). The present study confirmed the new perspectives on the sole use of SLNs in terms of saving time, without affecting the number of retrieved oocytes. Trial registration number and date of registration NCT03611907; July 26, 2018.
引用
收藏
页码:2866 / 2875
页数:10
相关论文
共 4 条
  • [1] A Monocentric Randomized Controlled Clinical Trial to Compare Single- and Double-Lumen Needles in Oocyte Retrieval Procedure in Assisted Reproductive Technologies
    Camilla Ronchetti
    Federico Cirillo
    Valentina Immediata
    Clara Gargasole
    Valeria Scolaro
    Emanuela Morenghi
    Elena Albani
    Pasquale Patrizio
    Paolo Emanuele Levi-Setti
    Reproductive Sciences, 2023, 30 : 2866 - 2875
  • [2] In vitro fertilization-intracytoplasmic sperm injection outcomes in single- versus double-lumen oocyte retrieval needles in normally responding patients: a randomized trial
    Haydardedeoglu, Bulent
    Cok, Tayfun
    Kilicdag, Esra Bulgan
    Parlakgumus, Ayse Huriye
    Simsek, Erhan
    Bagis, Tayfun
    FERTILITY AND STERILITY, 2011, 95 (02) : 812 - 814
  • [3] The impact of letrozole on oocyte quality in assisted reproductive technology (ART); a randomized double-blind clinical trial
    Rashidi, Batool Hossein
    Tehraninejad, Ensieh Shahrokh
    Amanpour, Saeed
    Bandarian, Fatemeh
    Bandarian, Mahin
    GYNECOLOGICAL ENDOCRINOLOGY, 2022, 38 (12) : 1087 - 1092
  • [4] Melatonin in Assisted Reproductive Technology: A Pilot Double-Blind Randomized Placebo-Controlled Clinical Trial
    Fernando, Shavi
    Wallace, Euan Morrison
    Vollenhoven, Beverley
    Lolatgis, Nicholas
    Hope, Nicole
    Wong, Melissa
    Lawrence, Mark
    Lawrence, Anthony
    Russell, Chris
    Leong, Kenneth
    Thomas, Philip
    Rombauts, Luk
    FRONTIERS IN ENDOCRINOLOGY, 2018, 9