Stem size and stem alignment affects periprosthetic fracture risk and primary stability in cementless total hip arthroplasty

被引:4
|
作者
Konow, Tobias [1 ]
Glismann, Katja [1 ]
Lampe, Frank [2 ]
Ondruschka, Benjamin [3 ]
Morlock, Michael M. [1 ]
Huber, Gerd [1 ]
机构
[1] TUHH Hamburg Univ Technol, Inst Biomech, Denickestr 15, D-21073 Hamburg, Germany
[2] Asklepios Klin Barmbek, Hamburg, Germany
[3] Univ Med Ctr Hamburg Eppendorf, Inst Legal Med, Hamburg, Germany
关键词
periprosthetic fracture; preoperative planning; primary stability; stem alignment; stem size; FEMORAL FRACTURES; COMPONENTS;
D O I
10.1002/jor.25729
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The ideal stem size and stem position is important for the success of total hip arthroplasty, since it can affect early implant loosening and periprosthetic fractures (PPF). This study aimed to investigate how small deviations from the ideal stem size and position influences the PPF risk and primary stability. Six experienced surgeons performed preoperative templating based on which the benchmark size for each femur was determined. Consecutive implantations were performed in six cadaveric femur pairs-one side was implanted with an undersized stem followed by the benchmark size and the contralateral side with a benchmark size followed by an oversized stem (Corail, Depuy Synthes). Moreover, three different alignments (six varus, six neutral, six valgus-undersized) were compared using 18 femurs. Cortical strains during broaching and implantation were measured, and laser scans were used to determine final stem position. All specimens underwent dynamic loading. Primary stability was estimated from stem subsidence and pull-out forces. Templated stem size varied between surgeons (+/- 1 size; p = 0.005). Undersizing increased stem subsidence by 320% (p < 0.001). Oversized stems exhibited 52% higher pull-out forces (p = 0.001) and 240% higher cortical strains (p = 0.056). Cortex strains increased with varus alignment (R-2 = 0.356, p = 0.011) while primary stability decreased with valgus stem alignment (p = 0.043). Surgeons should be aware that small deviations from the ideal stem size and malalignments of the stem can significantly alter the mechanical situation and affect the success of their surgery.
引用
收藏
页码:829 / 836
页数:8
相关论文
共 50 条
  • [41] Cementless total hip arthroplasty for patients previously treated with femoral osteotomy for hip dysplasia: the incidence of periprosthetic fracture
    Ohishi, Masanobu
    Nakashima, Yasuharu
    Yamamoto, Takuaki
    Motomura, Goro
    Fukushi, Jun-ichi
    Hamai, Satoshi
    Kohno, Yusuke
    Iwamoto, Yukihide
    INTERNATIONAL ORTHOPAEDICS, 2016, 40 (08) : 1601 - 1606
  • [42] Early Periprosthetic Femur Fractures After Primary Cementless Total Hip Arthroplasty: High Risk of Periprosthetic Joint Infection and Subsequent Reoperation
    Vasireddi, Nikhil
    Neitzke, Colin C.
    Chandi, Sonia K.
    Cororaton, Agnes D.
    Driscoll, Daniel A.
    Sculco, Peter K.
    Chalmers, Brian P.
    Gausden, Elizabeth B.
    JOURNAL OF ARTHROPLASTY, 2024, 39 (04): : 1083 - 1087.e1
  • [43] Cause-Specific Stem Revision Risk in Primary Total Hip Arthroplasty Using Cemented vs Cementless Femoral Stem Fixation in a US Cohort
    Kelly, Matthew P.
    Chan, Priscilla H.
    Prentice, Heather A.
    Paxton, Elizabeth W.
    Hinman, Adrian D.
    Khatod, Monti
    JOURNAL OF ARTHROPLASTY, 2022, 37 (01): : 89 - +
  • [44] Optimum stem length for mitigation of periprosthetic fracture risk following primary total knee arthroplasty: a finite element study
    Conlisk, Noel
    Howie, Colin R.
    Pankaj, Pankaj
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2018, 26 (05) : 1420 - 1428
  • [45] Cementless total hip arthroplasty for patients previously treated with femoral osteotomy for hip dysplasia: the incidence of periprosthetic fracture
    Masanobu Ohishi
    Yasuharu Nakashima
    Takuaki Yamamoto
    Goro Motomura
    Jun-ichi Fukushi
    Satoshi Hamai
    Yusuke Kohno
    Yukihide Iwamoto
    International Orthopaedics, 2016, 40 : 1601 - 1606
  • [46] Optimum stem length for mitigation of periprosthetic fracture risk following primary total knee arthroplasty: a finite element study
    Noel Conlisk
    Colin R. Howie
    Pankaj Pankaj
    Knee Surgery, Sports Traumatology, Arthroscopy, 2018, 26 : 1420 - 1428
  • [47] Short Stem Reverse Total Shoulder Arthroplasty Periprosthetic Type A Fracture
    Saltzman, Bryan M.
    Leroux, Timothy
    Collins, Michael J.
    Arns, Thomas A.
    Forsythe, Brian
    ORTHOPEDICS, 2017, 40 (04) : E721 - E724
  • [48] Primary total hip arthroplasty: Cemented or cementless
    DeBoer, DK
    TOPICS IN GERIATRIC REHABILITATION, 1996, 12 (01) : 1 - 8
  • [49] Outcomes of Primary Total Hip Arthroplasty in Systemic Lupus Erythematosus With a Proximally-Coated Cementless Stem
    Issa, Kimona
    Naziri, Qais
    Rasquinha, Vijay J.
    Tatevossian, Tiffany
    Kapadia, Bhaveen H.
    Mont, Michael A.
    JOURNAL OF ARTHROPLASTY, 2013, 28 (09): : 1663 - 1666
  • [50] Stem to prevent periprosthetic fracture after notching in total knee arthroplasty
    Wan, Qian
    Zhang, Aobo
    Liu, Yang
    Chen, Hao
    Zhao, Xue
    Han, Qing
    Wang, Jincheng
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2024, 40 (10)