Evaluation of colorimetric RT-LAMP for screening of SARS-CoV-2 in untreated wastewater

被引:8
作者
Akter, Jesmin [1 ,2 ,3 ]
Smith, Wendy J. M. [3 ]
Gebrewold, Metasebia [3 ]
Kim, Ilho [1 ,2 ]
Simpson, Stuart L. [4 ]
Bivins, Aaron [5 ]
Ahmed, Warish [3 ,6 ]
机构
[1] Univ Sci & Technol, Dept Civil & Environm Engn, Daejeon, South Korea
[2] Korea Inst Civil Engn & Bldg Technol KICT, Dept Environm Res, Goyang, South Korea
[3] CSIRO Environm, Ecosci Precinct, 41 Boggo Rd, Dutton Pk, Qld 4102, Australia
[4] CSIRO Environm, Lucas Heights, NSW 2234, Australia
[5] Louisiana State Univ, Dept Civil & Environm Engn, Baton Rouge, LA 70803 USA
[6] Ecosci Precinct, 41 Boggo Rd, Dutton Pk, Qld 4102, Australia
基金
新加坡国家研究基金会;
关键词
RT-LAMP; RT-qPCR; SARS-CoV-2; Surveillance; Wastewater; COVID-19; MEDIATED ISOTHERMAL AMPLIFICATION; POLYMERASE-CHAIN-REACTION; QUANTITATIVE DETECTION; RAPID DETECTION; COVID-19; SAMPLES; ASSAY; CHIP; PCR;
D O I
10.1016/j.scitotenv.2023.167964
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study compared reverse transcription-loop-mediated isothermal amplification (RT-LAMP) and three reverse transcription-quantitative polymerase chain reaction (RT-qPCR) assays targeting the N and E genes of the SARSCoV-2 genome for detecting RNA in untreated wastewater samples. RT-qPCR assays exhibited consistent amplification down to 2 x 102 GC/reaction, with greater analytical sensitivity at 2 x 101 GC/reaction by US CDC N1 and US CDC N2 assays. In contrast, RT-LAMP exhibited lower sensitivity, detecting SARS-CoV-2 only at or above 2 x 103 GC/reaction. For SARS-CoV-2 seeded wastewater samples, the US CDC N1 assay exhibited greater analytical sensitivity than the US CDC N2, E_Sarbeco, and RT-LAMP assays. Out of 30 wastewater samples, RTqPCR detected endogenous SARS-CoV-2 RNA in 29 samples, while RT-LAMP identified 27 positive samples, with 20 displaying consistent amplifications in all three RT-LAMP technical replicates. Agreement analysis revealed a strong concordance between RT-LAMP and the US CDC N1 and E_Sarbeco RT-qPCR assays (kappa = 0.474) but lower agreement with the US CDC N2 RT-qPCR assay (kappa = 0.359). Quantification of SARS-CoV-2 RNA in positive samples revealed a strong correlation between the US CDC N1 and E_Sarbeco assays, while the US CDC N1 and US CDC N2 assays exhibited weak correlation. Logistic regression analysis indicated that RT-LAMP results correlated with RNA quantified by the US CDC N1 and E_Sarbeco assays, with 95 % limits of detection of 3.99 and 3.47 log10 GC/15 mL, respectively. In conclusion, despite lower sensitivity compared to RT-qPCR assays, RTLAMP may offer advantages for wastewater surveillance, such as rapid results (estimated as twice as fast), and simplicity, making it a valuable tool in the shifting landscape of COVID-19 wastewater surveillance. Furthermore, LAMP positive wastewater samples might be prioritized for SARS-CoV-2 sequencing due to reduced analytical sensitivity. These findings support the use of RT-LAMP as a specific and efficient method for screening wastewater samples for SARS-CoV-2, particularly in resource-limited settings.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] RT-LAMP Multicenter Study for SARS-CoV-2 Genome Molecular Detection in Brazilian Swab and Saliva Samples
    da Costa, Vanessa Duarte
    Santos, Alanna Calheiros
    da Silva, Lucas Lima
    Wiggers, Wilian Jean
    Ivantes, Claudia Alexandra Pontes
    Lima, Danielle Malta
    Colares, Jeova Keny Baima
    Dallacqua, Deusilene Souza Vieira
    Motta-Castro, Ana Rita Coimbra
    Davila, Alberto Martin Rivera
    Teles, Sheila Araujo
    Carneiro, Megmar Aparecida dos Santos
    Caetano, Karlla Antonieta Amorim
    Anunciacao, Fernando Antonio Costa
    de Paula, Vanessa Salete
    Villar, Livia Melo
    DIAGNOSTICS, 2023, 13 (02)
  • [42] RT-LAMP in SARS-CoV-2 detection: point to improve primer designing and decrease molecular diagnosis pitfalls
    Teimouri, Hossein
    Rahimi, Maryam
    Taheri, Mahdeih
    Tabarraei, Alijan
    Shahbazi, Majid
    Omidvar, Shahriar
    Javid, Naeme
    Fazel, Abdolreza
    Honarvar, Mohammad Reza
    Roshandel, Gholamreza
    Abdollahi, Nafiseh
    Yamchi, Ahad
    Nikoo, Hadi Razavi
    EXPERT REVIEW OF MOLECULAR DIAGNOSTICS, 2022, 22 (10) : 953 - 961
  • [43] Colorimetric RT-LAMP Detection of Multiple SARS-CoV-2 Variants and Lineages of Concern Direct from Nasopharyngeal Swab Samples without RNA Isolation
    Werbajh, Santiago
    Larocca, Luciana
    Carrillo, Carolina
    Stolowicz, Fabiana
    Ogas, Lorena
    Pallotto, Sergio
    Cassara, Solange
    Mammana, Liliana
    Zapiola, Ines
    Bouzas, Maria Belen
    Vojnov, Adrian A.
    VIRUSES-BASEL, 2023, 15 (09):
  • [44] Evaluation of a field deployable, high-throughput RT-LAMP device as an early warning system for COVID-19 through SARS-CoV-2 measurements in wastewater
    Boza, J. M.
    Amirali, A.
    Williams, S. L.
    Currall, B. B.
    Grills, G. S.
    Mason, C. E.
    Solo-Gabriele, H. M.
    Erickson, D. C.
    SCIENCE OF THE TOTAL ENVIRONMENT, 2024, 944
  • [45] A colorimetric reverse transcription-loop mediated isothermal amplification (RT-LAMP) method for the rapid detection of SARS-CoV-2 in Thailand
    Bhakdeenuan, P.
    Bunchoo, S.
    Klayut, K.
    Srisungngam, S.
    Suphan, O.
    Kongthap, I.
    Suphankong, S.
    Phetsuksiri, B.
    Uppapong, B.
    Rudeeaneksin, J.
    TROPICAL BIOMEDICINE, 2024, 41 (01) : 64 - 69
  • [46] A molecular test based on RT-LAMP for rapid, sensitive and inexpensive colorimetric detection of SARS-CoV-2 in clinical samples
    Amaral, Catarina
    Antunes, Wilson
    Moe, Elin
    Duarte, Americo G.
    Lima, Luis M. P.
    Santos, Cristiana
    Gomes, Ines L.
    Afonso, Goncalo S.
    Vieira, Ricardo
    Teles, Helena Sofia S.
    Reis, Marisa S.
    Ramalho da Silva, Manuel A.
    Henriques, Ana Margarida
    Fevereiro, Miguel
    Ventura, M. Rita
    Serrano, Monica
    Pimentel, Catarina
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [47] Clinical validation of the isothermal rt-lamp test for the rapid diagnosis of SARS-CoV-2
    Hurtado, Leidy
    Diaz, Diana
    Escorcia, Katherine
    Florez, Laura
    Bello, Yesit
    Diaz, Yirys
    Navarro, Elkin
    Pacheco, Leonardo C.
    Galan, Nataly
    Maestre, Ronald
    Acosta, Antonio
    Pacheco, Lisandro A.
    BIOMEDICA, 2022, 42
  • [48] Integration of RT-LAMP and Microfluidic Technology for Detection of SARS-CoV-2 in Wastewater as an Advanced Point-of-Care Platform
    Ahmed Donia
    Muhammad Furqan Shahid
    Sammer-ul Hassan
    Ramla Shahid
    Aftab Ahmad
    Aneela Javed
    Muhammad Nawaz
    Tahir Yaqub
    Habib Bokhari
    Food and Environmental Virology, 2022, 14 : 364 - 373
  • [49] Implementation of a Rapid RT-LAMP Saliva-Based SARS-CoV-2 Testing Program in the Workplace
    Cook, Bradley W. M.
    Kobasa, Kaitlyn
    Tamayo, Marielou
    Theriault, Natasha
    Gordon Pappas, Diane
    Theriault, Steven S.
    DIAGNOSTICS, 2022, 12 (02)
  • [50] Label-free and portable field-effect sensor for monitoring RT-LAMP products to detect SARS-CoV-2 in wastewater
    Alvarez-Serna, Bryan E.
    Ramirez-Chavarria, Roberto G.
    Castillo-Villanueva, Elizabeth
    Carrillo-Reyes, Julian
    Maria Ramirez-Zamora, Rosa
    Buitron, German
    Alvarez-Icaza, Luis
    TALANTA, 2023, 253