Evaluation of colorimetric RT-LAMP for screening of SARS-CoV-2 in untreated wastewater

被引:8
|
作者
Akter, Jesmin [1 ,2 ,3 ]
Smith, Wendy J. M. [3 ]
Gebrewold, Metasebia [3 ]
Kim, Ilho [1 ,2 ]
Simpson, Stuart L. [4 ]
Bivins, Aaron [5 ]
Ahmed, Warish [3 ,6 ]
机构
[1] Univ Sci & Technol, Dept Civil & Environm Engn, Daejeon, South Korea
[2] Korea Inst Civil Engn & Bldg Technol KICT, Dept Environm Res, Goyang, South Korea
[3] CSIRO Environm, Ecosci Precinct, 41 Boggo Rd, Dutton Pk, Qld 4102, Australia
[4] CSIRO Environm, Lucas Heights, NSW 2234, Australia
[5] Louisiana State Univ, Dept Civil & Environm Engn, Baton Rouge, LA 70803 USA
[6] Ecosci Precinct, 41 Boggo Rd, Dutton Pk, Qld 4102, Australia
基金
新加坡国家研究基金会;
关键词
RT-LAMP; RT-qPCR; SARS-CoV-2; Surveillance; Wastewater; COVID-19; MEDIATED ISOTHERMAL AMPLIFICATION; POLYMERASE-CHAIN-REACTION; QUANTITATIVE DETECTION; RAPID DETECTION; COVID-19; SAMPLES; ASSAY; CHIP; PCR;
D O I
10.1016/j.scitotenv.2023.167964
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study compared reverse transcription-loop-mediated isothermal amplification (RT-LAMP) and three reverse transcription-quantitative polymerase chain reaction (RT-qPCR) assays targeting the N and E genes of the SARSCoV-2 genome for detecting RNA in untreated wastewater samples. RT-qPCR assays exhibited consistent amplification down to 2 x 102 GC/reaction, with greater analytical sensitivity at 2 x 101 GC/reaction by US CDC N1 and US CDC N2 assays. In contrast, RT-LAMP exhibited lower sensitivity, detecting SARS-CoV-2 only at or above 2 x 103 GC/reaction. For SARS-CoV-2 seeded wastewater samples, the US CDC N1 assay exhibited greater analytical sensitivity than the US CDC N2, E_Sarbeco, and RT-LAMP assays. Out of 30 wastewater samples, RTqPCR detected endogenous SARS-CoV-2 RNA in 29 samples, while RT-LAMP identified 27 positive samples, with 20 displaying consistent amplifications in all three RT-LAMP technical replicates. Agreement analysis revealed a strong concordance between RT-LAMP and the US CDC N1 and E_Sarbeco RT-qPCR assays (kappa = 0.474) but lower agreement with the US CDC N2 RT-qPCR assay (kappa = 0.359). Quantification of SARS-CoV-2 RNA in positive samples revealed a strong correlation between the US CDC N1 and E_Sarbeco assays, while the US CDC N1 and US CDC N2 assays exhibited weak correlation. Logistic regression analysis indicated that RT-LAMP results correlated with RNA quantified by the US CDC N1 and E_Sarbeco assays, with 95 % limits of detection of 3.99 and 3.47 log10 GC/15 mL, respectively. In conclusion, despite lower sensitivity compared to RT-qPCR assays, RTLAMP may offer advantages for wastewater surveillance, such as rapid results (estimated as twice as fast), and simplicity, making it a valuable tool in the shifting landscape of COVID-19 wastewater surveillance. Furthermore, LAMP positive wastewater samples might be prioritized for SARS-CoV-2 sequencing due to reduced analytical sensitivity. These findings support the use of RT-LAMP as a specific and efficient method for screening wastewater samples for SARS-CoV-2, particularly in resource-limited settings.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] A colorimetric RT-LAMP assay and LAMP-sequencing for detecting SARS-CoV-2 RNA in clinical samples
    Viet Loan Dao Thi
    Herbst, Konrad
    Boerner, Kathleen
    Meurer, Matthias
    Kremer, Lukas P. M.
    Kirrmaier, Daniel
    Freistaedter, Andrew
    Papagiannidis, Dimitrios
    Galmozzi, Carla
    Stanifer, Megan L.
    Boulant, Steeve
    Klein, Steffen
    Chlanda, Petr
    Khalid, Dina
    Miranda, Isabel Barreto
    Schnitzler, Paul
    Kraeusslich, Hans-Georg
    Knop, Michael
    Anders, Simon
    SCIENCE TRANSLATIONAL MEDICINE, 2020, 12 (556)
  • [22] Integration of RT-LAMP and Microfluidic Technology for Detection of SARS-CoV-2 in Wastewater as an Advanced Point-of-Care Platform
    Donia, Ahmed
    Shahid, Muhammad Furqan
    Sammer-Ul Hassan
    Shahid, Ramla
    Ahmad, Aftab
    Javed, Aneela
    Nawaz, Muhammad
    Yaqub, Tahir
    Bokhari, Habib
    FOOD AND ENVIRONMENTAL VIROLOGY, 2022, 14 (4) : 364 - 373
  • [23] Development, evaluation of the PNA RT-LAMP assay for rapid molecular detection of SARS-CoV-2
    Bat-Ochir, Chinbayar
    Kim, Yeon-Sook
    Kim, Han Gyeul
    Lee, Si Seok
    Lee, Han Woo
    Park, Hee Kyung
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [24] Colorimetric and fluorometric reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay for diagnosis of SARS-CoV-2
    Alhamid, Galyah
    Tombuloglu, Huseyin
    Motabagani, Dalal
    Motabagani, Dana
    Rabaan, Ali A.
    Unver, Kubra
    Dorado, Gabriel
    Al-Suhaimi, Ebtesam
    Unver, Turgay
    FUNCTIONAL & INTEGRATIVE GENOMICS, 2022, 22 (06) : 1391 - 1401
  • [25] Detection of SARS-CoV-2 RNA using RT-LAMP and molecular beacons
    Scott Sherrill-Mix
    Young Hwang
    Aoife M. Roche
    Abigail Glascock
    Susan R. Weiss
    Yize Li
    Leila Haddad
    Peter Deraska
    Caitlin Monahan
    Andrew Kromer
    Jevon Graham-Wooten
    Louis J. Taylor
    Benjamin S. Abella
    Arupa Ganguly
    Ronald G. Collman
    Gregory D. Van Duyne
    Frederic D. Bushman
    Genome Biology, 22
  • [26] Detection of SARS-CoV-2 RNA using RT-LAMP and molecular beacons
    Sherrill-Mix, Scott
    Hwang, Young
    Roche, Aoife M.
    Glascock, Abigail
    Weiss, Susan R.
    Li, Yize
    Haddad, Leila
    Deraska, Peter
    Monahan, Caitlin
    Kromer, Andrew
    Graham-Wooten, Jevon
    Taylor, Louis J.
    Abella, Benjamin S.
    Ganguly, Arupa
    Collman, Ronald G.
    Van Duyne, Gregory D.
    Bushman, Frederic D.
    GENOME BIOLOGY, 2021, 22 (01)
  • [27] Development of a rapid LFA test based on direct RT-LAMP for diagnosis of SARS-CoV-2
    Sadeghi, Negar
    Shirazi, Neda
    Dehbashi, Moein
    Maleki, Bahareh
    Cho, William C.
    Hojati, Zohreh
    PRACTICAL LABORATORY MEDICINE, 2024, 42
  • [28] High-quality RNA improves sensitivity of SARS-CoV-2 detection by colorimetric RT-LAMP
    Puigmule, Marta
    Coll, Monica
    Perez-Serra, Alexandra
    Lopez, Laura
    Pico, Ferran
    Neto, Nuria
    Corona, Monica
    Pinsach-Abuin, Mel-lina
    Ferrer-Costa, Carles
    Buxo, Maria
    Queralt, Francesc-Xavier
    Brugada, Ramon
    EXPERIMENTAL BIOLOGY AND MEDICINE, 2022, 247 (03) : 276 - 281
  • [29] Colorimetric RT-LAMP SARS-CoV-2 diagnostic sensitivity relies on color interpretation and viral load
    Aoki, Mateus Nobrega
    Coelho, Bruna de Oliveira
    Bentim Goes, Luiz Gustavo
    Minoprio, Paola
    Durigon, Edison Luiz
    Morello, Luis Gustavo
    Marchini, Fabricio Klerynton
    Riediger, Irina Natassja
    Debur, Maria do Carmo
    Nakaya, Helder I.
    Blanes, Lucas
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [30] Ultrasensitive and fast detection of SARS-CoV-2 using RT-LAMP without pH-dependent dye
    Alsaeed, Moneerah
    Alhamid, Galyah
    Tombuloglu, Huseyin
    Kabanja, Juma H.
    Karagoz, Aysel
    Tombuloglu, Guzin
    Rabaan, Ali A.
    Al-Suhaimi, Ebtesam
    Unver, Turgay
    FUNCTIONAL & INTEGRATIVE GENOMICS, 2024, 24 (01)