Evaluation of colorimetric RT-LAMP for screening of SARS-CoV-2 in untreated wastewater

被引:8
|
作者
Akter, Jesmin [1 ,2 ,3 ]
Smith, Wendy J. M. [3 ]
Gebrewold, Metasebia [3 ]
Kim, Ilho [1 ,2 ]
Simpson, Stuart L. [4 ]
Bivins, Aaron [5 ]
Ahmed, Warish [3 ,6 ]
机构
[1] Univ Sci & Technol, Dept Civil & Environm Engn, Daejeon, South Korea
[2] Korea Inst Civil Engn & Bldg Technol KICT, Dept Environm Res, Goyang, South Korea
[3] CSIRO Environm, Ecosci Precinct, 41 Boggo Rd, Dutton Pk, Qld 4102, Australia
[4] CSIRO Environm, Lucas Heights, NSW 2234, Australia
[5] Louisiana State Univ, Dept Civil & Environm Engn, Baton Rouge, LA 70803 USA
[6] Ecosci Precinct, 41 Boggo Rd, Dutton Pk, Qld 4102, Australia
基金
新加坡国家研究基金会;
关键词
RT-LAMP; RT-qPCR; SARS-CoV-2; Surveillance; Wastewater; COVID-19; MEDIATED ISOTHERMAL AMPLIFICATION; POLYMERASE-CHAIN-REACTION; QUANTITATIVE DETECTION; RAPID DETECTION; COVID-19; SAMPLES; ASSAY; CHIP; PCR;
D O I
10.1016/j.scitotenv.2023.167964
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study compared reverse transcription-loop-mediated isothermal amplification (RT-LAMP) and three reverse transcription-quantitative polymerase chain reaction (RT-qPCR) assays targeting the N and E genes of the SARSCoV-2 genome for detecting RNA in untreated wastewater samples. RT-qPCR assays exhibited consistent amplification down to 2 x 102 GC/reaction, with greater analytical sensitivity at 2 x 101 GC/reaction by US CDC N1 and US CDC N2 assays. In contrast, RT-LAMP exhibited lower sensitivity, detecting SARS-CoV-2 only at or above 2 x 103 GC/reaction. For SARS-CoV-2 seeded wastewater samples, the US CDC N1 assay exhibited greater analytical sensitivity than the US CDC N2, E_Sarbeco, and RT-LAMP assays. Out of 30 wastewater samples, RTqPCR detected endogenous SARS-CoV-2 RNA in 29 samples, while RT-LAMP identified 27 positive samples, with 20 displaying consistent amplifications in all three RT-LAMP technical replicates. Agreement analysis revealed a strong concordance between RT-LAMP and the US CDC N1 and E_Sarbeco RT-qPCR assays (kappa = 0.474) but lower agreement with the US CDC N2 RT-qPCR assay (kappa = 0.359). Quantification of SARS-CoV-2 RNA in positive samples revealed a strong correlation between the US CDC N1 and E_Sarbeco assays, while the US CDC N1 and US CDC N2 assays exhibited weak correlation. Logistic regression analysis indicated that RT-LAMP results correlated with RNA quantified by the US CDC N1 and E_Sarbeco assays, with 95 % limits of detection of 3.99 and 3.47 log10 GC/15 mL, respectively. In conclusion, despite lower sensitivity compared to RT-qPCR assays, RTLAMP may offer advantages for wastewater surveillance, such as rapid results (estimated as twice as fast), and simplicity, making it a valuable tool in the shifting landscape of COVID-19 wastewater surveillance. Furthermore, LAMP positive wastewater samples might be prioritized for SARS-CoV-2 sequencing due to reduced analytical sensitivity. These findings support the use of RT-LAMP as a specific and efficient method for screening wastewater samples for SARS-CoV-2, particularly in resource-limited settings.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Clinical Validation and Evaluation of a Colorimetric SARS-CoV-2 RT-LAMP Assay Against RT-PCR
    Erdem, Murat
    Andac-Ozketen, Ayse
    Ozketen, Ahmet Caglar
    Karahan, Gizem
    Tozluyurt, Abdullah
    Palaz, Fahreddin
    Alp, Alpaslan
    Unal, Serhat
    INFECTIOUS DISEASES AND CLINICAL MICROBIOLOGY, 2023, 5 (02): : 136 - 143
  • [2] Laboratory Evaluation of a SARS-CoV-2 RT-LAMP Test
    Menting, Sandra
    Erhart, Annette
    Schallig, Henk D. F. H.
    TROPICAL MEDICINE AND INFECTIOUS DISEASE, 2023, 8 (06)
  • [3] Development of an optimized RT-LAMP test for the detection of SARS-CoV-2
    Momenifar, Navid
    Pirouzfar, Mohammad
    Hashemian, Zohreh
    Amoli, Abdolreza Daneshvar
    BIOLOGICALS, 2023, 84
  • [4] Evaluation of SARS-CoV-2 RNA quantification by RT-LAMP compared to RT-qPCR
    Minami, Kenta
    Masutani, Ryota
    Suzuki, Youichi
    Kubota, Meri
    Osaka, Naofumi
    Nakanishi, Toyofumi
    Nakano, Takashi
    Ukimura, Akira
    JOURNAL OF INFECTION AND CHEMOTHERAPY, 2021, 27 (07) : 1068 - 1071
  • [5] Evaluation of RT-LAMP Assay for Rapid Detection of SARS-CoV-2
    Li, Ya-Ping
    Cao, Xun-Jie
    Luo, Xin
    Xie, Tian-Ao
    Liu, Wan-Jun
    Xie, Shi-Ming
    Lin, Min
    Guo, Xu-Guang
    LABORATORY MEDICINE, 2023, 54 (01) : 56 - 64
  • [6] Rapid and Reliable Detection of SARS-CoV-2 Using Direct RT-LAMP
    El-Kafrawy, Sherif A.
    El-Daly, Mai M.
    Hassan, Ahmed M.
    Harakeh, Steve M.
    Alandijany, Thamir A.
    Azhar, Esam, I
    DIAGNOSTICS, 2022, 12 (04)
  • [7] RT-LAMP: A Cheaper, Simpler and Faster Alternative for the Detection of SARS-CoV-2 in Wastewater
    Amoah, Isaac Dennis
    Mthethwa, Nonsikelelo Precios
    Pillay, Leanne
    Deepnarain, Nashia
    Pillay, Kriveshin
    Awolusi, Oluyemi Olatunji
    Kumari, Sheena
    Bux, Faizal
    FOOD AND ENVIRONMENTAL VIROLOGY, 2021, 13 (04) : 447 - 456
  • [8] RT-LAMP: A Cheaper, Simpler and Faster Alternative for the Detection of SARS-CoV-2 in Wastewater
    Isaac Dennis Amoah
    Nonsikelelo Precios Mthethwa
    Leanne Pillay
    Nashia Deepnarain
    Kriveshin Pillay
    Oluyemi Olatunji Awolusi
    Sheena Kumari
    Faizal Bux
    Food and Environmental Virology, 2021, 13 : 447 - 456
  • [9] Development of a RT-LAMP assay for detection of SARS-CoV-2
    Nandi, Shyam Sundar
    Lambe, Upendra Pradeep
    Sawant, Sonali Ankush
    Gohil, Trupti
    Deshpande, Jagadish
    INDIAN JOURNAL OF MEDICAL RESEARCH, 2022, 155 (01) : 148 - 155
  • [10] Detection of SARS-CoV-2 RNA in Urine by RT-LAMP: A Very Rare Finding
    Garcia-Bernalt Diego, Juan
    Fernandez-Soto, Pedro
    Munoz-Bellido, Juan Luis
    Febrer-Sendra, Begona
    Crego-Vicente, Beatriz
    Carbonell, Cristina
    Lopez-Bernus, Amparo
    Marcos, Miguel
    Belhassen-Garcia, Moncef
    Muro, Antonio
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (01)