Advanced Radio Frequency Applicators for Thermal Magnetic Resonance Theranostics of Brain Tumors

被引:6
作者
Saha, Nandita [1 ,2 ]
Kuehne, Andre [3 ,4 ]
Millward, Jason M. [1 ,2 ]
Eigentler, Thomas Wilhelm [1 ]
Starke, Ludger [1 ,5 ]
Waiczies, Sonia [1 ,2 ]
Niendorf, Thoralf [1 ,2 ,3 ]
机构
[1] Max Delbruck Ctr Mol Med Helmholtz Assoc MDC, Berlin Ultrahigh Field Facil BUFF, D-13125 Berlin, Germany
[2] Charite Univ Med Berlin, Joint Cooperat Charite Med Fac & Max Delbruck Ctr, Expt & Clin Res Ctr ECRC, D-13125 Berlin, Germany
[3] MRITOOLS GmbH, D-13125 Berlin, Germany
[4] Brightmind AI GmbH, A-1010 Vienna, Austria
[5] Univ Potsdam, Hasso Plattner Inst Digital Engn, D-14482 Potsdam, Germany
基金
欧盟地平线“2020”; 欧洲研究理事会;
关键词
theranostics; hyperthermia; brain tumor; MRI; ThermalMR; RF applicator; PHASED-ARRAY HYPERTHERMIA; CENTRAL-NERVOUS-SYSTEM; REGIONAL HYPERTHERMIA; IN-VIVO; NECK HYPERTHERMIA; TEMPERATURE; HEAD; SAR; OPTIMIZATION; LOOP;
D O I
10.3390/cancers15082303
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Simple Summary Localized thermal therapy has been reported to have clinical benefits as a potent sensitizer of chemo and radiotherapy for various cancers, and for facilitating targeted drug delivery. Thermal magnetic resonance (ThermalMR) integrates targeted radiofrequency (RF) induced heating in the hyperthermia (HT) range, together with diagnostic MRI and in vivo non-invasive temperature mapping within a single RF applicator for thermal theranostics. The potential of dipole antenna arrays for ThermalMR and hyperthermia RF applicators is well recognized, but the additional value of loop elements remains to be investigated. Therefore, we designed circular and elliptical ThermalMR RF applicator arrays with circular 360 degrees and horse-shoe shaped (arc = 270 degrees) coverage of the human head, combining loop antennas and self-grounded bow-tie (SGBT) dipole antennas in a hybrid design. We investigated the performance of these designs in terms of the MRI transmission B-1(+) field, RF power deposition to optimize targeted RF heating, using electromagnetic field (EMF) and temperature simulations performed on a virtual patient with a clinically realistic intracranial brain tumor. ThermalMR RF applicators with the hybrid loop+SGBT dipole design showed superior MRI performance and targeted RF heating inside the tumor, while preserving healthy tissue. Thermal Magnetic Resonance (ThermalMR) is a theranostic concept that combines diagnostic magnetic resonance imaging (MRI) with targeted thermal therapy in the hyperthermia (HT) range using a radiofrequency (RF) applicator in an integrated system. ThermalMR adds a therapeutic dimension to a diagnostic MRI device. Focused, targeted RF heating of deep-seated brain tumors, accurate non-invasive temperature monitoring and high-resolution MRI are specific requirements of ThermalMR that can be addressed with novel concepts in RF applicator design. This work examines hybrid RF applicator arrays combining loop and self-grounded bow-tie (SGBT) dipole antennas for ThermalMR of brain tumors, at magnetic field strengths of 7.0 T, 9.4 T and 10.5 T. These high-density RF arrays improve the feasible transmission channel count, and provide additional degrees of freedom for RF shimming not afforded by using dipole antennas only, for superior thermal therapy and MRI diagnostics. These improvements are especially relevant for ThermalMR theranostics of deep-seated brain tumors because of the small surface area of the head. ThermalMR RF applicators with the hybrid loop+SGBT dipole design outperformed applicators using dipole-only and loop-only designs, with superior MRI performance and targeted RF heating. Array variants with a horse-shoe configuration covering an arc (270 degrees) around the head avoiding the eyes performed better than designs with 360 degrees coverage, with a 1.3 degrees C higher temperature rise inside the tumor while sparing healthy tissue. Our EMF and temperature simulations performed on a virtual patient with a clinically realistic intracranial tumor provide a technical foundation for implementation of advanced RF applicators tailored for ThermalMR theranostics of brain tumors.
引用
收藏
页数:29
相关论文
共 50 条
  • [21] Diagnostic value of Magnetic Resonance Spectroscopy (MRS) for detection of Brain Tumors in patients
    Hekmatnia, Ali
    Sabouri, Masih
    Ghazavi, Amir Hosein
    Far, Peyman Shahriyari
    Hekmatnia, Farzaneh
    Sofi, Ghazaleh Jamalipour
    Alikhani, Fariba
    Salehi, Mina
    MEDICAL SCIENCE, 2019, 23 (100) : 939 - 945
  • [22] Magnetic Resonance Imaging Spectroscopy in Pediatric Atypical Teratoid Rhabdoid Tumors of the Brain
    Bruggers, Carol S.
    Moore, Kevin
    JOURNAL OF PEDIATRIC HEMATOLOGY ONCOLOGY, 2014, 36 (06) : E341 - E345
  • [23] Advanced magnetic resonance imaging findings in salivary gland tumors
    Gokce, Erkan
    Beyhan, Murat
    WORLD JOURNAL OF RADIOLOGY, 2022, 14 (08): : 256 - 271
  • [24] Advanced magnetic resonance imaging techniques for tumors of the head and neck
    Santos Armentia, E.
    Martin Noguerol, T.
    Suarez Vega, V.
    RADIOLOGIA, 2019, 61 (03): : 191 - 203
  • [25] Magnetic resonance-guided laser interstitial thermal therapy: report of a series of pediatric brain tumors
    Tovar-Spinoza, Zulma
    Choi, Hoon
    JOURNAL OF NEUROSURGERY-PEDIATRICS, 2016, 17 (06) : 723 - 733
  • [26] Radiomic analysis of magnetic resonance fingerprinting in adult brain tumors
    Dastmalchian, Sara
    Kilinc, Ozden
    Onyewadume, Louisa
    Tippareddy, Charit
    McGivney, Debra
    Ma, Dan
    Griswold, Mark
    Sunshine, Jeffrey
    Gulani, Vikas
    Barnholtz-Sloan, Jill S.
    Sloan, Andrew E.
    Badve, Chaitra
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2021, 48 (03) : 683 - 693
  • [27] Proton magnetic resonance spectroscopy of brain tumors correlated with pathology
    Magalhaes, A
    Godfrey, W
    Shen, YM
    Hu, JN
    Smith, W
    ACADEMIC RADIOLOGY, 2005, 12 (01) : 51 - 57
  • [28] Presurgical functional magnetic resonance imaging in patients with brain tumors
    Ravn, Soren
    Holmberg, Mats
    Sorensen, Preben
    Frokjaer, Jens B.
    Carl, Jesper
    ACTA RADIOLOGICA, 2016, 57 (01) : 82 - 89
  • [29] Diffusion tensor magnetic resonance imaging of glial brain tumors
    Ferda, Jiri
    Kastner, Jan
    Mukensnabl, Petr
    Choc, Milan
    Horemuzova, Jana
    Ferdova, Eva
    Kreuzberg, Boris
    EUROPEAN JOURNAL OF RADIOLOGY, 2010, 74 (03) : 428 - 436
  • [30] The Potential of Relaxation-Weighted Sodium Magnetic Resonance Imaging as Demonstrated on Brain Tumors
    Nagel, Armin Michael
    Bock, Michael
    Hartmann, Christian
    Gerigk, Lars
    Neumann, Jan-Oliver
    Weber, Marc-Andre
    Bendszus, Martin
    Radbruch, Alexander
    Wick, Wolfgang
    Schlemmer, Heinz-Peter
    Semmler, Wolfhard
    Biller, Armin
    INVESTIGATIVE RADIOLOGY, 2011, 46 (09) : 539 - 547