Simultaneous determination of diquat, paraquat, glufosinate, and glyphosate in plasma by liquid chromatography/tandem mass spectrometry: from method development to clinical application

被引:2
作者
Liu, Maozhu [1 ,2 ]
Fan, Fei [3 ]
Zhang, Jing [4 ,5 ]
Fang, Shiyong [6 ]
Bai, Yangjuan [1 ]
Li, Yamei [1 ]
Zou, Yuangao [1 ]
An, Yunfei [1 ]
Dai, Xinhua [1 ]
机构
[1] Sichuan Univ, West China Hosp, Dept Lab Med, Chengdu 610041, Sichuan, Peoples R China
[2] Sichuan Univ, West China Hosp, Dept Pharm, Chengdu 610041, Sichuan, Peoples R China
[3] Sichuan Univ, West China Sch Basic Med Sci & Forens Med, Chengdu 610041, Sichuan, Peoples R China
[4] Sichuan Univ, West China Sch Publ Hlth, Chengdu 610041, Sichuan, Peoples R China
[5] Sichuan Univ, West China Hosp 4, Chengdu 610041, Sichuan, Peoples R China
[6] Wannan Med Coll, Sch Forens Med, Wuhu 241002, Anhui, Peoples R China
关键词
Diquat; Paraquat; Glufosinate; Glyphosate; Human plasma; LC-MS/MS; METABOLITES; SERUM; QUANTITATION; URINE;
D O I
10.1007/s00216-024-05257-1
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Diquat (DQ), paraquat (PQ), glufosinate (GLU), and glyphosate (GLYP) are commonly used herbicides that have been confirmed to be toxic to humans. Rapid and accurate measurements of these toxicants in clinical practice are beneficial for the correct diagnosis and timely treatment of herbicide-poisoned patients. The present study aimed to establish an efficient, convenient, and reliable method to achieve the simultaneous quantification of DQ, PQ, GLU, and GLYP in human plasma using liquid chromatography-tandem mass spectrometry (LC-MS/MS) without using derivatization or ion-pairing reagents. DQ, PQ, GLU, and GLYP were extracted by the rapid protein precipitation and liquid-liquid extraction method and then separated and detected by LC-MS/MS. Subsequently, linearity, limit of detection (LOD), limit of quantification (LOQ), precision, accuracy, extraction recovery, matrix effect, dilution integrity, and stability were evaluated to validate the method based on the FDA criteria. Finally, the validated method was applied to real plasma samples collected from 166 Chinese patients with herbicide poisoning. The results showed satisfactory linearity with low LOD (1 ng/mL for DQ and PQ, 5 ng/mL for GLU, and 10 ng/mL for GLYP, respectively) and low LOQ (5 ng/mL for DQ and PQ, 25 ng/mL for GLU and GLYP, respectively). In addition, the precision, accuracy, extraction recovery, and stability of the method were acceptable. The matrix effect was not observed in the analyzed samples. Moreover, the developed method was successfully applied to determine the target compounds in real plasma samples. These data provided reliable evidence for the application of this LC-MS/MS method for clinical poisoning detection.
引用
收藏
页码:3073 / 3083
页数:11
相关论文
共 25 条
[1]  
[Anonymous], 2018, Bioanalytical method validation guidance for industry
[2]   Investigation of the separation of heterocyclic aromatic amines by reversed phase ion-pair liquid chromatography coupled with tandem mass spectrometry: The role of ion pair reagents on LC-MS/MS sensitivity [J].
Bianchi, F ;
Careri, A ;
Corradini, C ;
Elviri, L ;
Mangia, A ;
Zagnoni, I .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 825 (02) :193-200
[3]  
Chamkasem N., 2017, J REGIONAL SCI, V5, P1, DOI [10.21423/jrs-v05n01p001, DOI 10.21423/JRS-V05N02P001]
[4]   Direct determination of glyphosate, glufosinate, and AMPA in soybean and corn by liquid chromatography/tandem mass spectrometry [J].
Chamkasem, Narong ;
Harmon, Tiffany .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2016, 408 (18) :4995-5004
[5]  
Fuke Chiaki, 2002, Leg Med (Tokyo), V4, P156, DOI 10.1016/S1344-6223(02)00011-1
[6]   Optimized liquid chromatography tandem mass spectrometry approach for the determination of diquat and paraquat herbicides [J].
Hao, Chunyan ;
Zhao, Xiaoming ;
Morse, David ;
Yang, Paul ;
Taguchi, Vince ;
Morra, Franca .
JOURNAL OF CHROMATOGRAPHY A, 2013, 1304 :169-176
[7]   Spectra interference between diquat and paraquat by second derivative spectrophotometry [J].
Kuo, TL ;
Lin, DL ;
Liu, RH ;
Moriya, F ;
Hashimoto, Y .
FORENSIC SCIENCE INTERNATIONAL, 2001, 121 (1-2) :134-139
[8]   A Method for the Analysis of Glyphosate, Aminomethylphosphonic Acid, and Glufosinate in Human Urine Using Liquid Chromatography-Tandem Mass Spectrometry [J].
Li, Zhong-Min ;
Kannan, Kurunthachalam .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2022, 19 (09)
[9]   Validation and application of analytical method for glyphosate and glufosinate in foods by liquid chromatography-tandem mass spectrometry [J].
Liao, Yang ;
Berthion, Jean-Marie ;
Colet, Isabelle ;
Merlo, Mathilde ;
Nougadere, Alexandre ;
Hu, Renwei .
JOURNAL OF CHROMATOGRAPHY A, 2018, 1549 :31-38
[10]   Acute human Glufosinate-containing herbicide poisoning [J].
Mao, Yan-Chiao ;
Hung, Dong-Zong ;
Wu, Ming-Ling ;
Tsai, Wei-Jen ;
Wang, Lee-Min ;
Ger, Jiin ;
Deng, Jou-Fang ;
Yang, Chen-Chang .
CLINICAL TOXICOLOGY, 2012, 50 (05) :396-402