Motion compensated cone-beam CT reconstruction using an a priori motion model from CT simulation: a pilot study

被引:1
作者
Lauria, Michael [1 ]
Miller, Claudia [1 ]
Singhrao, Kamal [2 ,3 ]
Lewis, John [4 ]
Lin, Weicheng [1 ]
O'Connell, Dylan [1 ]
Naumann, Louise [1 ]
Stiehl, Bradley [4 ]
Santhanam, Anand [1 ]
Boyle, Peter [1 ]
Raldow, Ann C. [1 ]
Goldin, Jonathan [5 ]
Barjaktarevic, Igor [6 ]
Low, Daniel A. [1 ]
机构
[1] UCLA, Los Angeles, CA 90095 USA
[2] Brigham & Womens Hosp, Dana Farber Canc Inst, Boston, MA USA
[3] Harvard Med Sch, Dept Radiat Oncol, Boston, MA USA
[4] Cedars Sinai Med Ctr, Dept Radiat Oncol, Los Angeles, CA USA
[5] Dept Radiol Sci, UCLA, Los Angeles, CA USA
[6] Dept Pulm & Crit Care Med, UCLA, Los Angeles, CA USA
关键词
CBCT; model-based CT; motion compensation; IMAGE-GUIDED RADIOTHERAPY; COMPUTED-TOMOGRAPHY; RESPIRATORY MOTION; LOCALIZATION; REGISTRATION; ACQUISITION; ARTIFACTS; QUALITY;
D O I
10.1088/1361-6560/ad311b
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. To combat the motion artifacts present in traditional 4D-CBCT reconstruction, an iterative technique known as the motion-compensated simultaneous algebraic reconstruction technique (MC-SART) was previously developed. MC-SART employs a 4D-CBCT reconstruction to obtain an initial model, which suffers from a lack of sufficient projections in each bin. The purpose of this study is to demonstrate the feasibility of introducing a motion model acquired during CT simulation to MC-SART, coined model-based CBCT (MB-CBCT). Approach. For each of 5 patients, we acquired 5DCTs during simulation and pre-treatment CBCTs with a simultaneous breathing surrogate. We cross-calibrated the 5DCT and CBCT breathing waveforms by matching the diaphragms and employed the 5DCT motion model parameters for MC-SART. We introduced the Amplitude Reassignment Motion Modeling technique, which measures the ability of the model to control diaphragm sharpness by reassigning projection amplitudes with varying resolution. We evaluated the sharpness of tumors and compared them between MB-CBCT and 4D-CBCT. We quantified sharpness by fitting an error function across anatomical boundaries. Furthermore, we compared our MB-CBCT approach to the traditional MC-SART approach. We evaluated MB-CBCT's robustness over time by reconstructing multiple fractions for each patient and measuring consistency in tumor centroid locations between 4D-CBCT and MB-CBCT. Main results. We found that the diaphragm sharpness rose consistently with increasing amplitude resolution for 4/5 patients. We observed consistently high image quality across multiple fractions, and observed stable tumor centroids with an average 0.74 +/- 0.31 mm difference between the 4D-CBCT and MB-CBCT. Overall, vast improvements over 3D-CBCT and 4D-CBCT were demonstrated by our MB-CBCT technique in terms of both diaphragm sharpness and overall image quality. Significance. This work is an important extension of the MC-SART technique. We demonstrated the ability of a priori 5DCT models to provide motion compensation for CBCT reconstruction. We showed improvements in image quality over both 4D-CBCT and the traditional MC-SART approach.
引用
收藏
页数:19
相关论文
共 62 条
[1]   SIMULTANEOUS ALGEBRAIC RECONSTRUCTION TECHNIQUE (SART) - A SUPERIOR IMPLEMENTATION OF THE ART ALGORITHM [J].
ANDERSEN, AH ;
KAK, AC .
ULTRASONIC IMAGING, 1984, 6 (01) :81-94
[2]  
[Anonymous], 2012, Imaging in Medicine, DOI [10.2217/iim.12.13, DOI 10.2217/IIM.12.13]
[3]   Independent review of 4DCT scans used for SABR treatment planning [J].
Antony, Rachitha ;
Lonski, Peta ;
Ungureanu, Elena ;
Hardcastle, Nicholas ;
Yeo, Adam ;
Siva, Shankar ;
Kron, Tomas .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (03) :62-67
[4]   Results from the AAPM Task Group 324 respiratory motion management in radiation oncology survey [J].
Ball, Helen J. ;
Santanam, Lakshmi ;
Senan, Suresh ;
Tanyi, James A. ;
van Herk, Marcel ;
Keall, Paul J. .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (11)
[5]   Adaptive Radiotherapy: Moving Into the Future [J].
Brock, Kristy K. .
SEMINARS IN RADIATION ONCOLOGY, 2019, 29 (03) :181-184
[6]   Low dose cone beam CT for paediatric image-guided radiotherapy: Image quality and practical recommendations [J].
Bryce-Atkinson, Abigail ;
De Jong, Rianne ;
Marchant, Tom ;
Whitfield, Gillian ;
Aznar, Marianne C. ;
Bel, Arjan ;
van Herk, Marcel .
RADIOTHERAPY AND ONCOLOGY, 2021, 163 :68-75
[7]   Image-guided radiotherapy: rationale, benefits, and limitations [J].
Dawson, Laura A. ;
Sharpe, Michael B. .
LANCET ONCOLOGY, 2006, 7 (10) :848-858
[8]   A Method for Assessing Ground-Truth Accuracy of the 5DCT Technique [J].
Dou, Tai H. ;
Thomas, David H. ;
O'Connell, Dylan P. ;
Lamb, James M. ;
Lee, Percy ;
Low, Daniel A. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 93 (04) :925-933
[9]   Machine learning and modeling: Data, validation, communication challenges [J].
El Naqa, Issam ;
Ruan, Dan ;
Valdes, Gilmer ;
Dekker, Andre ;
McNutt, Todd ;
Ge, Yaorong ;
Wu, Q. Jackie ;
Oh, Jung Hun ;
Thor, Maria ;
Smith, Wade ;
Rao, Arvind ;
Fuller, Clifton ;
Xiao, Ying ;
Manion, Frank ;
Schipper, Matthew ;
Mayo, Charles ;
Moran, Jean M. ;
Ten Haken, Randall .
MEDICAL PHYSICS, 2018, 45 (10) :E834-E840
[10]   PRACTICAL CONE-BEAM ALGORITHM [J].
FELDKAMP, LA ;
DAVIS, LC ;
KRESS, JW .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06) :612-619