Predicting voxel-level dose distributions of single-isocenter volumetric modulated arc therapy treatment plan for multiple brain metastases

被引:0
作者
Huang, Peng [1 ]
Shang, Jiawen [1 ]
Hu, Zhihui [1 ]
Liu, Zhiqiang [1 ]
Yan, Hui [1 ]
机构
[1] Chinese Acad Med Sci & Peking Union Med Coll, Natl Canc Ctr, Natl Clin Res Ctr Canc, Dept Radiat Oncol,Canc Hosp, Beijing, Peoples R China
关键词
multiple brain metastases; volumetric modulated arc therapy; radiotherapy; deep learning; dose prediction; RADIOSURGERY; RADIOTHERAPY; MANAGEMENT; QUALITY;
D O I
10.3389/fonc.2024.1339126
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose Brain metastasis is a common, life-threatening neurological problem for patients with cancer. Single-isocenter volumetric modulated arc therapy (VMAT) has been popularly used due to its highly conformal dose and short treatment time. Accurate prediction of its dose distribution can provide a general standard for evaluating the quality of treatment plan. In this study, a deep learning model is applied to the dose prediction of a single-isocenter VMAT treatment plan for radiotherapy of multiple brain metastases.Method A U-net with residual networks (U-ResNet) is employed for the task of dose prediction. The deep learning model is first trained from a database consisting of hundreds of historical treatment plans. The 3D dose distribution is then predicted with the input of the CT image and contours of regions of interest (ROIs). A total of 150 single-isocenter VMAT plans for multiple brain metastases are used for training and testing. The model performance is evaluated based on mean absolute error (MAE) and mean absolute differences of multiple dosimetric indexes (DIs), including (D max and D mean) for OARs, (D 98, D 95, D 50, and D 2) for PTVs, homogeneity index, and conformity index. The similarity between the predicted and clinically approved plan dose distribution is also evaluated.Result For 20 tested patients, the largest and smallest MAEs are 3.3% +/- 3.6% and 1.3% +/- 1.5%, respectively. The mean MAE for the 20 tested patients is 2.2% +/- 0.7%. The mean absolute differences of D 98, D 95, D 50, and D2 for PTV60, PTV52, PTV50, and PTV40 are less than 2.5%, 3.0%, 2.0%, and 3.0%, respectively. The prediction accuracy of OARs for D max and D mean is within 3.2% and 1.2%, respectively. The average DSC ranges from 0.86 to 1 for all tested patients.Conclusion U-ResNet is viable to produce accurate dose distribution that is comparable to those of the clinically approved treatment plans. The predicted results can be used to improve current treatment planning design, plan quality, efficiency, etc.
引用
收藏
页数:8
相关论文
共 40 条
[1]   Knowledge-based automated planning with three-dimensional generative adversarial networks [J].
Babier, Aaron ;
Mahmood, Rafid ;
McNiven, Andrea L. ;
Diamant, Adam ;
Chan, Timothy C. Y. .
MEDICAL PHYSICS, 2020, 47 (02) :297-306
[2]   Three-dimensional dose prediction for lung IMRT patients with deep neural networks: robust learning from heterogeneous beam configurations [J].
Barragan-Montero, Ana Maria ;
Dan Nguyen ;
Lu, Weiguo ;
Lin, Mu-Han ;
Norouzi-Kandalan, Roya ;
Geets, Xavier ;
Sterpin, Edmond ;
Jiang, Steve .
MEDICAL PHYSICS, 2019, 46 (08) :3679-3691
[3]   Stereotactic radiosurgery for brain metastases: current status and future directions [J].
Boehling, Nicholas S. ;
Chang, Eric L. ;
Ma, Lijun ;
Phan, Nicolas ;
Yeung, Robert ;
Sahgal, Arjun .
JOURNAL OF RADIATION ONCOLOGY, 2012, 1 (03) :245-253
[4]   Innovative Therapeutic Strategies in the Treatment of Brain Metastases [J].
Caffo, Maria ;
Barresi, Valeria ;
Caruso, Gerardo ;
Cutugno, Mariano ;
La Fata, Giuseppe ;
Venza, Mario ;
Alafaci, Concetta ;
Tomasello, Francesco .
INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2013, 14 (01) :2135-2174
[5]   A feasibility study on an automated method to generate patient-specific dose distributions for radiotherapy using deep learning [J].
Chen, Xinyuan ;
Men, Kuo ;
Li, Yexiong ;
Yi, Junlin ;
Dai, Jianrong .
MEDICAL PHYSICS, 2019, 46 (01) :56-64
[6]   Plan quality and treatment planning technique for single isocenter cranial radiosurgery with volumetric modulated arc therapy [J].
Clark, Grant M. ;
Popple, Richard A. ;
Prendergast, Brendan M. ;
Spencer, Sharon A. ;
Thomas, Evan M. ;
Stewart, John G. ;
Guthrie, Barton L. ;
Markert, James M. ;
Fiveash, John B. .
PRACTICAL RADIATION ONCOLOGY, 2012, 2 (04) :306-313
[7]   FEASIBILITY OF SINGLE-ISOCENTER VOLUMETRIC MODULATED ARC RADIOSURGERY FOR TREATMENT OF MULTIPLE BRAIN METASTASES [J].
Clark, Grant M. ;
Popple, Richard A. ;
Young, P. Edward ;
Fiveash, John B. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 76 (01) :296-302
[8]   3D radiotherapy dose prediction on head and neck cancer patients with a hierarchically densely connected U-net deep learning architecture [J].
Dan Nguyen ;
Jia, Xun ;
Sher, David ;
Lin, Mu-Han ;
Iqbal, Zohaib ;
Liu, Hui ;
Jiang, Steve .
PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (06)
[9]   A feasibility study for predicting optimal radiation therapy dose distributions of prostate cancer patients from patient anatomy using deep learning [J].
Dan Nguyen ;
Long, Troy ;
Jia, Xun ;
Lu, Weiguo ;
Gu, Xuejun ;
Iqbal, Zohaib ;
Jiang, Steve .
SCIENTIFIC REPORTS, 2019, 9 (1)
[10]   Automatic treatment planning based on three-dimensional dose distribution predicted from deep learning technique [J].
Fan, Jiawei ;
Wang, Jiazhou ;
Chen, Zhi ;
Hu, Chaosu ;
Zhang, Zhen ;
Hu, Weigang .
MEDICAL PHYSICS, 2019, 46 (01) :370-381