Characterisation of Cartilage Damage via Fusing Mid-Infrared, Near-Infrared, and Raman Spectroscopic Data

被引:2
作者
Shaikh, Rubina [1 ,2 ]
Tafintseva, Valeria [3 ]
Nippolainen, Ervin [1 ]
Virtanen, Vesa [4 ]
Solheim, Johanne [3 ]
Zimmermann, Boris [3 ]
Saarakkala, Simo [4 ,5 ]
Toyras, Juha [1 ,6 ,7 ]
Kohler, Achim [3 ]
Afara, Isaac O. [1 ,7 ]
机构
[1] Univ Eastern Finland, Dept Tech Phys, Kuopio 70211, Finland
[2] Technol Univ Dublin, Sch Phys Clin & Optometr Sci, Dublin D07XT95, Ireland
[3] Norwegian Univ Life Sci, Fac Sci & Technol, N-1432 As, Norway
[4] Univ Oulu, Res Unit Med Imaging Phys & Technol, Oulu 90570, Finland
[5] Univ Oulu, Res Unit Hlth Sci & Technol, Oulu 90220, Finland
[6] Kuopio Univ Hosp, Sci Serv Ctr, Kuopio 70210, Finland
[7] Univ Queensland, Sch Informat Technol & Elect Engn, Brisban, Qld 4072, Australia
来源
JOURNAL OF PERSONALIZED MEDICINE | 2023年 / 13卷 / 07期
基金
欧盟地平线“2020”; 芬兰科学院;
关键词
post-traumatic osteoarthritis; articular cartilage; data fusion; partial least squares discriminant analysis; CLASSIFICATION; OSTEOARTHRITIS; STRATEGY;
D O I
10.3390/jpm13071036
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Mid-infrared spectroscopy (MIR), near-infrared spectroscopy (NIR), and Raman spectroscopy are all well-established analytical techniques in biomedical applications. Since they provide complementary chemical information, we aimed to determine whether combining them amplifies their strengths and mitigates their weaknesses. This study investigates the feasibility of the fusion of MIR, NIR, and Raman spectroscopic data for characterising articular cartilage integrity. Osteochondral specimens from bovine patellae were subjected to mechanical and enzymatic damage, and then MIR, NIR, and Raman data were acquired from the damaged and control specimens. We assessed the capacity of individual spectroscopic methods to classify the samples into damage or control groups using Partial Least Squares Discriminant Analysis (PLS-DA). Multi-block PLS-DA was carried out to assess the potential of data fusion by combining the dataset by applying two-block (MIR and NIR, MIR and Raman, NIR and Raman) and three-block approaches (MIR, NIR, and Raman). The results of the one-block models show a higher classification accuracy for NIR (93%) and MIR (92%) than for Raman (76%) spectroscopy. In contrast, we observed the highest classification efficiency of 94% and 93% for the two-block (MIR and NIR) and three-block models, respectively. The detailed correlative analysis of the spectral features contributing to the discrimination in the three-block models adds considerably more insight into the molecular origin of cartilage damage.
引用
收藏
页数:12
相关论文
共 33 条
[1]   Observer reliability in the arthroscopic classification of osteoarthritis of the knee [J].
Brismar, BH ;
Wredmark, T ;
Movin, T ;
Leandersson, J ;
Svensson, O .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2002, 84B :42-47
[2]   Evaluation of cartilage injuries and repair [J].
Brittberg, M ;
Winalski, CS .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A :58-69
[3]   Combining Chemical Information From Grass Pollen in Multimodal Characterization [J].
Diehn, Sabrina ;
Zimmermann, Boris ;
Tafintseva, Valeria ;
Seifert, Stephan ;
Bagcioglu, Murat ;
Ohlson, Mikael ;
Weidner, Steffen ;
Fjellheim, Siri ;
Kohler, Achim ;
Kneipp, Janina .
FRONTIERS IN PLANT SCIENCE, 2020, 10
[4]   Fiber-optic Raman spectroscopy of joint tissues [J].
Esmonde-White, Karen A. ;
Esmonde-White, Francis W. L. ;
Morris, Michael D. ;
Roessler, Blake J. .
ANALYST, 2011, 136 (08) :1675-1685
[5]   Multivariate Chemical Image Fusion of Vibrational Spectroscopic Imaging Modalities [J].
Gowen, Aoife A. ;
Dorrepaal, Ronan M. .
MOLECULES, 2016, 21 (07)
[6]   Clinical outcome of autologous chondrocyte implantation is correlated with infrared spectroscopic imaging-derived parameters [J].
Hanifi, A. ;
Richardson, J. B. ;
Kuiper, J. H. ;
Roberts, S. ;
Pleshko, N. .
OSTEOARTHRITIS AND CARTILAGE, 2012, 20 (09) :988-996
[7]   Comparison of Individual and Integrated Inline Raman, Near-Infrared, and Mid-Infrared Spectroscopic Models to Predict the Viscosity of Micellar Liquids [J].
Haroon, Kiran ;
Arafeh, Ali ;
Cunliffe, Stephanie ;
Martin, Philip ;
Rodgers, Thomas ;
Mendoza, Cesar ;
Baker, Michael .
APPLIED SPECTROSCOPY, 2020, 74 (07) :819-831
[8]  
Hiligsmann M., 2013, MEDICOGRAPHIA, V35, P197
[9]   Synergy Effect of Combined Near and Mid-Infrared Fibre Spectroscopy for Diagnostics of Abdominal Cancer [J].
Hocotz, Thaddaus ;
Bibikova, Olga ;
Belikova, Valeria ;
Bogomolov, Andrey ;
Usenov, Iskander ;
Pieszczek, Lukasz ;
Sakharova, Tatiana ;
Minet, Olaf ;
Feliksberger, Elena ;
Artyushenko, Viacheslav ;
Rau, Beate ;
Zabarylo, Urszula .
SENSORS, 2020, 20 (22) :1-19
[10]   Osteoarthritis [J].
Hunter, David J. ;
Bierma-Zeinstra, Sita .
LANCET, 2019, 393 (10182) :1745-1759