摘要
Significance: Parametric imaging of the attenuation coefficient mu(OCT) using optical coherence tomography (OCT) is a promising approach for evaluating abnormalities in tissue. To date, a standardized measure of accuracy and precision of mu(OCT) by the depth-resolved estimation (DRE) method, as an alternative to least squares fitting, is missing. Aim: We present a robust theoretical framework to determine accuracy and precision of the DRE of mu(OCT). Approach: We derive and validate analytical expressions for the accuracy and precision of mu(OCT) determination by the DRE using simulated OCT signals in absence and presence of noise. We compare the theoretically achievable precisions of the DRE method and the least-squares fitting approach. Results: Our analytical expressions agree with the numerical simulations for high signal-to-noise ratios and qualitatively describe the dependence on noise otherwise. A commonly used simplification of the DRE method results in a systematic overestimation of the attenuation coefficient in the order of mu(2)(OCT) x Delta, where Delta is the pixel stepsize. When mu(OCT) center dot |AFR| less than or similar to 1.8, mu(OCT) is reconstructed with higher precision by the depth-resolved method compared to fitting over the length of an axial fitting range |AFR|. Conclusions: We derived and validated expressions for the accuracy and precision of DRE of mu(OCT). A commonly used simplification of this method is not recommended as being used for OCT-attenuation reconstruction. We give a rule of thumb providing guidance in the choice of estimation method. (c) The Authors. Published by SPIE under a Creative Commons Attribution 4.0 International License. Distribution or reproduction of this work in whole or in part requires full attribution of the original publication, including its DOI.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Depth-resolved photothermal optical coherence tomography by local optical path length change measurement
    Makita, Shuichi
    Hong, Young-Joo
    Li, En
    Yoshiaki, Yasuno
    OPTICAL ELASTOGRAPHY AND TISSUE BIOMECHANICS III, 2016, 9710
  • [22] RECONSTRUCTION OF DEPTH-RESOLVED FIBER ORIENTATIONS IN THE BRAIN WITH POLARIZATION SENSITIVE OPTICAL COHERENCE TOMOGRAPHY
    Wang, H.
    Boas, D.
    Akkin, T.
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2016, 36 : 388 - 389
  • [23] Extraction and compensation for depth-resolved phase error in spectral domain optical coherence tomography
    Zhang, Xianling
    Gao, Wanrong
    Chen, Chaoliang
    Bian, Haiyi
    Zhu, Yue
    Zhongguo Jiguang/Chinese Journal of Lasers, 2014, 41 (02):
  • [24] Techniques for extraction of depth-resolved in vivo human retinal intrinsic optical signals with optical coherence tomography
    Tumlinson, Alexandre R.
    Hermann, Boris
    Hofer, Bernd
    Povazay, Boris
    Margrain, Tom H.
    Binns, Alison M.
    Drexler, Wolfgang
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2009, 53 (04) : 315 - 326
  • [25] Techniques for extraction of depth-resolved in vivo human retinal intrinsic optical signals with optical coherence tomography
    Alexandre R. Tumlinson
    Boris Hermann
    Bernd Hofer
    Boris Považay
    Tom H. Margrain
    Alison M. Binns
    Wolfgang Drexler
    Japanese Journal of Ophthalmology, 2009, 53 : 315 - 326
  • [26] Depth-Resolved Physiological Response of Retina to Transcorneal Electrical Stimulation Measured With Optical Coherence Tomography
    Sun, Pengcheng
    Li, Qian
    Li, Heng
    Di, Liqing
    Su, Xiaofan
    Chen, Jianpin
    Zheng, Hao
    Chen, Yao
    Zhou, Chuanqing
    Chai, Xinyu
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2019, 27 (05) : 905 - 915
  • [27] Optical coherence tomography (OCT) reveals depth-resolved dynamics during functional brain activation
    Chen, Yu
    Aguirre, Aaron D.
    Ruvinskaya, Lana
    Devor, Anna
    Boas, David A.
    Fujimoto, James G.
    JOURNAL OF NEUROSCIENCE METHODS, 2009, 178 (01) : 162 - 173
  • [28] Optical coherence elastography to evaluate depth-resolved elasticity of tissue
    Yang, Chenming
    Xiang, Zhen
    Li, Zhongliang
    Nan, Nan
    Wang, Xiangzhao
    OPTICS EXPRESS, 2022, 30 (06): : 8709 - 8722
  • [29] Depth-resolved local reflectance spectra measurements in full-field optical coherence tomography
    Claveau, Remy
    Montgomery, Paul
    Flury, Manuel
    Montaner, Denis
    OPTICS EXPRESS, 2017, 25 (17): : 20216 - 20232
  • [30] High resolution coherence domain depth-resolved nailfold capillaroscopy based on correlation mapping optical coherence tomography
    Subhash, Hrebesh M.
    O'Gorman, Sean
    Neuhaus, Kai
    Leahy, Martin
    OPTICAL DIAGNOSTICS AND SENSING XIV: TOWARD POINT-OF-CARE DIAGNOSTICS, 2014, 8951