Predicting Habitual Use of Wearable Health Devices Among Middle-aged Individuals With Metabolic Syndrome Risk Factors in South Korea: Cross-sectional Study

被引:3
作者
Ha, Jaeyoung [1 ]
Park, Jungmi [1 ]
Lee, Sangyi [1 ]
Lee, Jeong [2 ]
Choi, Jin-Young [1 ]
Kim, Junhyoung [1 ]
Cho, Sung-il [1 ,3 ]
Jeon, Gyeong-Suk [4 ,5 ]
机构
[1] Seoul Natl Univ, Grad Sch Publ Hlth, Dept Publ Hlth Sci, Seoul, South Korea
[2] Chodang Univ, Dept Nursing, Muan, South Korea
[3] Seoul Natl Univ, Inst Hlth & Environm, Seoul, South Korea
[4] Mokpo Natl Univ, Dept Nursing, Muan, South Korea
[5] Mokpo Natl Univ, Dept Nursing, 1666 Yeongsan Ro, Cheonggye Myeon 58554, Muan, South Korea
关键词
wearable health devices; HBM; UTAUT2; habitual use; metabolic syndrome; wearables; digital intervention; health promotion; predictors of use; acceptability; INFORMATION-TECHNOLOGY; ACCEPTANCE; CONSTRUCT;
D O I
10.2196/42087
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Background: Prevention of the risk factors for metabolic syndrome (MetS) in middle-aged individuals is an important public health issue. Technology-mediated interventions, such as wearable health devices, can aid in lifestyle modification, but they require habitual use to sustain healthy behavior. However, the underlying mechanisms and predictors of habitual use of wearable health devices among middle-aged individuals remain unclear.Objective: We investigated the predictors of habitual use of wearable health devices among middle-aged individuals with risk factors for MetS.Methods: We proposed a combined theoretical model based on the health belief model, the Unified Technology of Acceptance and Use of Technology 2, and perceived risk. We conducted a web-based survey of 300 middle-aged individuals with MetS between September 3 and 7, 2021. We validated the model using structural equation modeling.Results: The model explained 86.6% of the variance in the habitual use of wearable health devices. The goodness-of-fit indices revealed that the proposed model has a desirable fit with the data. Performance expectancy was the core variable explaining the habitual use of wearable devices. The direct effect of the performance expectancy on habitual use of wearable devices was greater (beta=.537, P<.001) than that of intention to continue use (beta=.439, P<.001), and the total effect estimate of the performance expectancy was 0.909 (P<.001), including the indirect effect (beta=.372, P=.03) on habitual use of wearable devices via intention to continue use. Furthermore, performance expectancy was influenced by health motivation (beta=.497, P<.001), effort expectancy (beta=.558, P<.001), and risk perception (beta=.137, P=.02). Perceived vulnerability (beta=.562, P<.001) and perceived severity (beta=.243, P=.008) contributed to health motivation.Conclusions: The results suggest the importance of the users' performance expectations for wearable health devices for the intention of continued use for self-health management and habituation. Based on our results, developers and health care practitioners should find better ways to meet the performance expectations of middle-aged individuals with MetS risk factors. They also should generate device use easier and find a way to encourage users' health motivation, thereby reducing users' effort expectancy and resulting in a reasonable performance expectancy of the wearable health device, to induce users' habitual use behaviors.
引用
收藏
页数:16
相关论文
共 65 条
  • [1] Discriminant Validity Assessment: Use of Fornell & Larcker criterion versus HTMT Criterion
    Ab Hamid, M. R.
    Sami, W.
    Sidek, M. H. Mohmad
    [J]. 1ST INTERNATIONAL CONFERENCE ON APPLIED & INDUSTRIAL MATHEMATICS AND STATISTICS 2017 (ICOAIMS 2017), 2017, 890
  • [2] Ahadzadeh Ashraf Sadat, 2015, J Med Internet Res, V17, pe45, DOI 10.2196/jmir.3564
  • [3] Alturki MR, 2016, INT J ENG RES TECHNO, V5, P197, DOI [10.15623/ijret.2016.0509032, DOI 10.15623/IJRET.2016.0509032]
  • [4] An Soontae, 2018, [Journal of Public Relations, 홍보학연구], V22, P53, DOI 10.15814/jpr.2018.22.6.53
  • [5] [Anonymous], 2022, STAT MET SYNDR RISK
  • [6] A weight and a meta-analysis on mobile banking acceptance research
    Baptista, Goncalo
    Oliveira, Tiago
    [J]. COMPUTERS IN HUMAN BEHAVIOR, 2016, 63 : 480 - 489
  • [7] Bauer R. A., 1960, P 41 C AM MARK ASS, P389
  • [8] Using smartwatches for fitness and health monitoring: the UTAUT2 combined with threat appraisal as moderators
    Beh, Phaik Khee
    Ganesan, Yuvaraj
    Iranmanesh, Mohammad
    Foroughi, Behzad
    [J]. BEHAVIOUR & INFORMATION TECHNOLOGY, 2021, 40 (03) : 282 - 299
  • [9] Cha MH, 2008, J KOREAN SOC FOOD SC, V37, P1435, DOI [10.3746/jkfn.2008.37.11.1435, DOI 10.3746/JKFN.2008.37.11.1435]
  • [10] Why Do Older Adults Use Wearable Devices: A Case Study Adopting the Senior Technology Acceptance Model (STAM)
    Chu Yu-Huei
    Chen Ja-Shen
    Wang Ming-Chao
    [J]. 2019 PORTLAND INTERNATIONAL CONFERENCE ON MANAGEMENT OF ENGINEERING AND TECHNOLOGY (PICMET), 2019,