Application of different Trombe wall solutions on the reduction of energy load and sustainable development in an eco-resort residential building in Binalood region with a cold and dry climate

被引:5
作者
Sady, Hamed [1 ]
Rashidi, Saman [1 ]
Rafee, Roohollah [2 ]
机构
[1] Semnan Univ, Fac New Sci & Technol, Dept Energy, Semnan, Iran
[2] Semnan Univ, Fac Mech Engn, Semnan, Iran
关键词
Trombe wall; Energy consumption; Zero energy building; Heating load demand; Cold and dry climate; Natural ventilation; NATURAL VENTILATION; SOLAR-ENERGY; PERFORMANCE; GENERATION; SYSTEM; FLOW;
D O I
10.1007/s11356-023-27039-5
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Trombe wall is a passive strategy that reduces the energy consumption in buildings and helps for sustainable development of the residential sector. Applying these walls is very important in areas that need heating load in winter. This study evaluates a set of Trombe walls for the energy management of a residential building under real conditions in Binalood region with a cold and dry climate. In order to study the potentials of the Trombe wall, four different designs, including cubic Trombe wall with rectangular structure and three-sided glass, Trombe wall with trapezoidal structure and three-sided glass, Trombe wall with trapezoidal structure and four-sided glass, and Trombe wall with thicker storage wall, trapezoidal structure, and three-sided glass, for Trombe wall are considered. Trombe walls of all four suggested designs are exposed to outdoor conditions and installed at 17 places on the southern walls of the residential building. The results show that the most optimal design, i.e., Trombe wall with thicker storage wall, trapezoidal structure, and three-sided glass, leads to the greatest decrease (1637 kWh) in heating load in January. In addition, this design of the Trombe wall has the greatest effect in increasing the indoor air temperature among other Trombe walls investigated in this study. The Trombe wall with thicker storage wall, trapezoidal structure, and three-sided glass with a storage wall thickness of 40 cm is able to reduce the heating load of the building by 5.59 MWh in 5 months. This plan reduces the energy demand of the building by 8% more than the conventional structure of Trombe wall.
引用
收藏
页码:68417 / 68434
页数:18
相关论文
共 47 条
[1]   Experimental, analytical, and numerical investigation into the feasibility of integrating a passive Trombe wall into a single room [J].
Abdeen, Ahmed ;
Serageldin, Ahmed A. ;
Ibrahim, Mona G. E. ;
El-Zafarany, Abbas ;
Ookawara, Shinichi ;
Murata, Ryo .
APPLIED THERMAL ENGINEERING, 2019, 154 :751-768
[2]   Solar energy potentials in Iran: A review [J].
Alamdari, Pouria ;
Nematollahi, Omid ;
Alemrajabi, Ali Akbar .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2013, 21 :778-788
[3]  
Analytics GARD, 2004, EnergyPlus Testing with ANSI/ASHRAE Standard 140-2001 (BESTEST)
[4]   CFD analyses for passive house with Trombe wall and impact to energy demand [J].
Bajc, Tamara ;
Todorovic, Maja N. ;
Svorcan, Jelena .
ENERGY AND BUILDINGS, 2015, 98 :39-44
[5]   Standing up for the Paris Agreement: Do global climate targets influence individuals' greenhouse gas emissions? [J].
Bauer, Andreas ;
Menrad, Klaus .
ENVIRONMENTAL SCIENCE & POLICY, 2019, 99 :72-79
[6]   Are Trombe walls suitable passive systems for the reduction of the yearly building energy requirements? [J].
Bevilacqua, Piero ;
Benevento, Federica ;
Bruno, Roberto ;
Arcuri, Natale .
ENERGY, 2019, 185 :554-566
[7]  
Bin C., 2006, RENEWABLE ENERGY P, P600
[8]   Experimental and analytical approach on the Trombe wall thermal performance parameters characterization [J].
Briga-Sa, Ana ;
Boaventura-Cunha, Jose ;
Lanzinha, Joao-Carlos ;
Paiva, Anabela .
ENERGY AND BUILDINGS, 2017, 150 :262-280
[9]   Energy performance of Trombe walls: Adaptation of ISO 13790:2008(E) to the Portuguese reality [J].
Briga-Sa, Ana ;
Martins, Analisa ;
Boaventura-Cunha, Jose ;
Lanzinha, Joao Carlos ;
Paiva, Anabela .
ENERGY AND BUILDINGS, 2014, 74 :111-119
[10]   Occupancy schedules learning process through a data mining framework [J].
D'Oca, Simona ;
Hong, Tianzhen .
ENERGY AND BUILDINGS, 2015, 88 :395-408