Comparison of positional artifacts in myocardial perfusion imaging in supine and semi-reclining position using dedicated D-SPECT cardiac camera: validation using CT based attenuation correction

被引:6
作者
Chopra, Sejal [1 ]
Singh, Shashank Shekhar [1 ]
Sood, Ashwani [1 ]
Parmar, Madan [1 ]
Parihar, Ashwin Singh [1 ]
Vadi, Shelvin Kumar [1 ]
Mittal, Bhagwant Rai [1 ]
机构
[1] Postgrad Inst Med Educ & Res PGIMER, Dept Nucl Med, Chandigarh, India
关键词
SPECT; MPI; image analysis; CAD; myocardial ischemia; infarction; NUCLEAR CARDIOLOGY; SYSTEM;
D O I
10.1007/s12350-023-03210-w
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Soft-tissue attenuation remains a major limitation of SPECT-MPI which interferes with the diagnosis of CAD. The current study aims to evaluate the pattern of attenuation artifacts in supine and semi-reclining positions on CZT cardiac camera and their interaction with gender, BMI and stress protocols. Methods. We prospectively analysed 150 patients acquired in supine and semi-reclining positions on CZT camera. The images were evaluated for severity and extent of defect using 17-segment model. An additional CT scan was acquired to generate AC image in the first 50 patients studied to assist investigator learning for comparison of artifact vs true defects in the two SPECT systems. The defects present in one position or showing change in severity within two positions were considered as positional artifacts and further validated using CTAC supine image. Results. In overall analysis, higher extent and severity of positional artifacts were observed more in semi-reclining position affecting the apex, apico-inferior, inferolateral and inferoseptal segments. Females showed more positional artifacts than males with inferior wall attenuation in the semireclining position and anterior wall attenuation in the supine position. A positive correlation of the extent and severity of positional artifacts was noted with an increasing BMI. In patients with BMI > 30, mid inferior and inferolateral segments were most affected followed by anterior wall segments. Highest correction of artifactual perfusion defects by CTAC was noted in inferior wall followed by inferolateral segments. Conclusion. The incidence of positional artifacts was greater in semi-reclining position in females, higher BMI groups and adenosine stress subsets. Knowledge of the pattern of positional artifacts appears to be a reliable alternative of CTAC for correct interpretation of myocardial perfusion images.
引用
收藏
页码:1782 / 1793
页数:12
相关论文
共 26 条
[1]   Pitfalls and artifacts using the D-SPECT dedicated cardiac camera [J].
Allie, Rayjanah ;
Hutton, Brian F. ;
Prvulovich, Elizabeth ;
Bomanji, Jamshed ;
Michopoulou, Sofia ;
Ben-Haim, Simona .
JOURNAL OF NUCLEAR CARDIOLOGY, 2016, 23 (02) :301-310
[2]   Contributions of nuclear cardiology to diagnosis and prognosis of patients with coronary artery disease [J].
Beller, GA ;
Zaret, BL .
CIRCULATION, 2000, 101 (12) :1465-1478
[3]  
Ben-Haim S, 2009, J NUCL MED, V50
[4]   SPECT/CT imaging: Clinical utility of an emerging technology [J].
Bybel, Bohdan ;
Brunken, Richard C. ;
DiFilippo, Frank P. ;
Neumann, Donald R. ;
Wu, Guiyun ;
Cerqueira, Manuel D. .
RADIOGRAPHICS, 2008, 28 (04) :1097-1113
[5]   Diagnostic accuracy of cadmium-zinc-telluride-based myocardial perfusion SPECT: impact of attenuation correction using a co-registered external computed tomography [J].
Caobelli, Federico ;
Akin, Muharrem ;
Thackeray, James T. ;
Brunkhorst, Thomas ;
Widder, Julian ;
Berding, Georg ;
Burchert, Ina ;
Bauersachs, Johann ;
Bengel, Frank M. .
EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2016, 17 (09) :1036-1043
[6]  
Cardiology, 2012, IAEA HUM HLTH SER, V23
[7]   Soft tissue attenuation patterns in stress myocardial perfusion SPECT images: A comparison between supine and upright acquisition systems [J].
Chawla, David ;
Rahaby, Mouyyad ;
Amin, Amit P. ;
Vashistha, Raj ;
Alyousef, Tareq ;
Martinez, Hector X. ;
Doukky, Rami .
JOURNAL OF NUCLEAR CARDIOLOGY, 2011, 18 (02) :281-290
[8]   Soft Tissue Attenuation Patterns Associated with Upright Acquisition SPECT Myocardial Perfusion Imaging: A Descriptive Study [J].
Doukky, Rami ;
Rahaby, Mouyyad ;
Chawla, Dave ;
Vashistha, Raj ;
Alyousef, Tareq ;
Amin, Amit P. .
OPEN CARDIOVASCULAR MEDICINE JOURNAL, 2012, 6 :22-27
[9]   SPECT attenuation correction: An essential tool to realize nuclear cardiology's manifest destiny [J].
Garcia, Ernest V. .
JOURNAL OF NUCLEAR CARDIOLOGY, 2007, 14 (01) :16-24
[10]  
Hendel, 2004, INTERPRETATION MYOCA, P157