The standardised Malay version of purdue pegboard test: Content validity and test-retest reliability testing

被引:2
|
作者
Poo, Yin Sin [1 ]
Chai, Siaw Chui [1 ]
Goh, Poh Im [1 ]
Kadar, Masne [1 ]
Razab, Nor Afifi Razaob [1 ]
机构
[1] Univ Kebangsaan Malaysia, Fac Hlth Sci, Ctr Rehabil & Special Needs Studies, Occupat Therapy Programme, Jalan Raja Muda Abdul Aziz, Kuala Lumpur 50300, Malaysia
关键词
Fine motor manipulation; coordination testing; hand function evaluation; translation; psychometrics; INTRACLASS CORRELATION-COEFFICIENT; INSTRUMENTS; VALIDATION; PEOPLE; NORMS;
D O I
10.1177/15691861231179012
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
IntroductionPurdue Pegboard Test (PPT) is a valid and reliable instrument for measuring hand dexterity among individuals with or without medical conditions. In the Southeast Asia region where Malay is widely spoken, there is a need to have a Malay translation of Purdue Pegboard Test. This study aimed to translate the PPT into the Malay version (PPT-M) and to determine the content validity and test-retest reliability of this translated version.MethodsThis study involved: (1) four English teachers (translators) for forward and backward translation procedures; (2) 10 experts in the field of occupational therapy (expert reviewers) for content validity testing; and (3) 60 undergraduate students (participants) for test-retest reliability testing.ResultsPPT-M had excellent content validity with Item-Content Validity Index = 0.9-1.0, Scale-Content Validity Index/Average = 0.93-0.95, and a slightly lower Scale-Content Validity Index/Universal Agreement = 0.25-0.75. Test-retest reliability for 3-trial administration (n = 30; Intraclass Correlation Coefficients, ICCs = 0.76-0.85; good) was higher compared to 1-trial administration (n = 30; ICCs = 0.34-0.46; poor) for all subtests. Both trial administrations were mostly affected by systematic errors, especially practice effect as the retests gave higher scores. Random errors mostly affected Subtest 3 of 1-trial administration, evident by its Minimal Detectable Change Percent values = 30.84% that fell beyond the acceptable range.ConclusionPPT-M has the potential to be a valuable instrument for measuring hand dexterity among Malay speaking individuals especially when the 3-trial administration is used.
引用
收藏
页码:84 / 91
页数:8
相关论文
共 50 条
  • [41] Test-retest reliability of the PDQ-Carer
    Morley, David
    Dummett, Sarah
    Kelly, Laura
    Jenkinson, Crispin
    PARKINSONISM & RELATED DISORDERS, 2022, 102 : 16 - 18
  • [42] Psychometric Evaluation of the Dutch Version of the Assessment of Preschool Children's Participation (APCP): Construct Validity and Test-Retest Reliability
    Bult, Maureen K.
    Verschuren, Olaf
    Kertoy, Marilyn K.
    Lindeman, Eline
    Jongmans, Marian J.
    Ketelaar, Marjolijn
    PHYSICAL & OCCUPATIONAL THERAPY IN PEDIATRICS, 2013, 33 (04) : 372 - 383
  • [43] Test-retest reliability, convergent validity and cross-cultural adaptation of Turkish version of the Hand10 questionnaire
    Tore, Nurten Gizem
    Tuna, Zeynep
    Mete, Oguzhan
    Gokkurt, Ahmet
    Seven, Baris
    Oskay, Deran
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2022, 27 (02) : 380 - 383
  • [44] Test-Retest Reliability for Aerodynamic Measures of Voice
    Awan, Shaheen N.
    Novaleski, Carolyn K.
    Yingling, Julie R.
    JOURNAL OF VOICE, 2013, 27 (06) : 674 - 684
  • [45] Interrater and test-retest reliability and validity of the Norwegian version of the BESTest and mini-BESTest in people with increased risk of falling
    Hamre, Charlotta
    Botolfsen, Pernille
    Tangen, Gro Gujord
    Helbostad, Jorunn L.
    BMC GERIATRICS, 2017, 17
  • [46] Translation, Cultural Adaptation and Test-retest Reliability of the German Version of the Headache Disability Questionnaire
    Ivanov, Dimo
    Ernst, Markus J. J.
    PHYSIOSCIENCE, 2023, 19 (03) : 124 - 133
  • [47] Test-retest reliability and rater agreements of Assessment of Capacity for Myoelectric Control version 2.0
    Lindner, Helen Y. N.
    Langius-Eklof, Ann
    Hermansson, Liselotte M. N.
    JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT, 2014, 51 (04) : 635 - 644
  • [48] Test-retest reliability of Quantitative Sensory Testing in knee osteoarthritis and healthy participants
    Wylde, V.
    Palmer, S.
    Learmonth, I. D.
    Dieppe, P.
    OSTEOARTHRITIS AND CARTILAGE, 2011, 19 (06) : 655 - 658
  • [49] Six-minute stepper test in hospitalized elderly patients: Convergent validity, test-retest reliability and safety
    Francisco, Davi de Souza
    Martinez, Larissa
    Terrazas, Aline Carleto
    Ribeiro, Diego Britto
    Yamaguti, Wellington Pereira
    PLOS ONE, 2020, 15 (10):
  • [50] Test-Retest Reliability of a Computerized Concussion Test: CNS Vital Signs
    Littleton, Ashley C.
    Register-Mihalik, Johna K.
    Guskiewicz, Kevin M.
    SPORTS HEALTH-A MULTIDISCIPLINARY APPROACH, 2015, 7 (05): : 443 - 447