Influence of cooling methods on high-temperature residual mechanical characterization of strain-hardening cementitious composites

被引:0
作者
Kumar, Dhanendra [1 ,2 ]
Soliman, Amr A. [2 ]
Ranade, Ravi [2 ]
机构
[1] Nanyang Technol Univ NTU, Sch Civil & Environm Engn, 50 Nanyang Ave, Singapore 639798, Singapore
[2] Univ Buffalo State Univ New York, Dept Civil Struct & Environm Engn CSEE, Buffalo, NY USA
关键词
cooling; ECC; fire; high temperature; quenching; residual strength; SHCC; size-effect; ELEVATED-TEMPERATURES; NORMAL STRENGTH; STEEL FIBERS; FLY-ASH; CONCRETE; MICROSTRUCTURE; PERFORMANCE; EXPOSURE; FIRE; PVA;
D O I
10.1002/fam.3187
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Residual strength tests are commonly used to characterize the high-temperature mechanical properties of concrete materials. In these tests, the specimens are heated to a target temperature in a furnace and then cooled down to room temperature, followed by mechanical testing at room temperature. This research investigates the influence of the cooling method on the residual strength of Strain Hardening Cementitious Composites (SHCC) after exposure to 400 degrees C and 600 degrees C. Two types of cooling methods - furnace-cooling (within a closed furnace) and water-cooling (immersed in a water tank) - were adopted. Four different SHCC previously investigated by the authors for high-temperature residual mechanical and bond behavior with steel were studied. Two different specimen sizes were tested under uniaxial compression and flexure to characterize the residual compressive strength and modulus of rupture. The effect of the cooling method was prominent for the normalized residual modulus of rupture at 400 degrees C, but not at 600 degrees C. The cooling method had no effect on the normalized residual compressive strength of any material at either of the two temperatures, except one of the SHCC (PVA-SC) at 400 degrees C. Specimen size also had no effect on the normalized residual compressive strength and modulus of rupture irrespective of the cooling method.
引用
收藏
页码:338 / 352
页数:15
相关论文
共 60 条
  • [1] Bond-slip behaviour of steel fibres in concrete after exposure to elevated temperatures
    Abdallah, Sadoon
    Fan, Mizi
    Cashell, K. A.
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2017, 140 : 542 - 551
  • [2] [Anonymous], 2004, EN 1992-1-2: Eurocode 2: Design of Concrete Structures - Part 1-2: General Rules - Structural Fire Design
  • [3] [Anonymous], PRODUCT DATA SHEETS
  • [4] [Anonymous], 2018, STANDARD TEST METHOD
  • [5] [Anonymous], 2017, STANDARD SPECIFICATI
  • [6] [Anonymous], 2008, ENG CEMENTITIOUS COM
  • [7] [Anonymous], 2015, Standard practice for capping cylindrical concrete specimens (ASTM C617/C617M-15)
  • [8] [Anonymous], 2019, Standard Practice for Making and Curing Concrete Test Specimens in the Laboratory
  • [9] Retained properties of concrete exposed to high temperatures: Size effect
    Arioz, Omer
    [J]. FIRE AND MATERIALS, 2009, 33 (05) : 211 - 222
  • [10] ASTM, 2018, Standard Specification for Aviation Turbine Fuel Containing Synthesized Hydrocarbons, DOI DOI 10.1520/C0033_C0033M-18