Effect of confining stirrups and bar gap in improving bond behavior of glass fiber reinforced polymer (GFRP) bar lap splices in RC beams

被引:23
作者
Abbas, Husain [1 ]
Elsanadedy, Hussein [1 ]
Alaoud, Louai [1 ]
Almusallam, Tarek [1 ]
Al-Salloum, Yousef [1 ]
机构
[1] King Saud Univ, Coll Engn, Chair Res & Studies Strengthening & Rehabilitat S, Dept Civil Engn, POB 800, Riyadh 11421, Saudi Arabia
关键词
Lap splice; Development length; Concrete; GFRP rebars; Beams; Bond; STRENGTH; PERFORMANCE;
D O I
10.1016/j.conbuildmat.2022.129943
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Fiber-reinforced polymer (FRP) bars are becoming a popular replacement for steel rebars that are vulnerable to corrosion, especially under harsh corrosive environments. Despite several advantages for using FRP rebars, the bond between FRP bars and surrounding concrete has been a major concern that affects the behavior of FRPreinforced structural members. The experimental program of this study comprises testing eight full-scale glass FRP (GFRP) reinforced beams under two-point loads. There were two control beams and six beams having rebar lap splices. The beams were reinforced using 2 phi 12 GFRP bars. The first control had continuous GFRP bars, and the 2nd control had GFRP lap splice conforming to the relevant ACI code. The lap splice was 65 times the bar diameter in six beams having lap splice. The contact lap and non-contact laps were used along with the variable spacing of shear stirrups in the lap zone (50, 100 mm, infinity, i.e., no shear stirrups). The lap splice, designed conforming to the ACI code, was found to be very conservative. The reduction in shear stirrups' spacing in the lap zone and the gap between lapped bars was found to enhance the bond performance of GFRP bars by up to 31 %. The authors' previous models for predicting development length and bond are found to show good predictions for the experimental results of the present study as well. Analytical models are developed for predicting with sufficient precision the peak load for GFRP reinforced beams with the two types of lap splices (non-contact and contact).
引用
收藏
页数:22
相关论文
共 24 条
[1]  
ACI Committee 318, 2019, 31819 ASTM
[2]  
ACI Committee 440, 2015, ACI 440.1R-15: Guide for the Design and Construction of Structural Concrete Reinforced with Fiber-Reinforced Polymer Bars
[3]   Bond Performance of GFRP Bar-Splicing in Reinforced Concrete Beams [J].
Al-Salloum, Yousef ;
Alaoud, Louai ;
Elsanadedy, Hussein ;
Albidah, Abdulrahman ;
Almusallam, Tarek ;
Abbas, Husain .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2022, 26 (02)
[4]   Effect of harsh environmental conditions on the tensile properties of GFRP bars [J].
Al-Salloum, Yousef A. ;
El-Gamal, Sherif ;
Almusallam, Tarek H. ;
Alsayed, Saleh H. ;
Aqel, Mohammed .
COMPOSITES PART B-ENGINEERING, 2013, 45 (01) :835-844
[5]   Stress along tensile lap-spliced fibre reinforced polymer reinforcing bars in concrete [J].
Aly, Ragi .
CANADIAN JOURNAL OF CIVIL ENGINEERING, 2007, 34 (09) :1149-1158
[6]  
Aly R, 2006, ACI STRUCT J, V103, P857
[7]   Tensile lap splicing of bundled CFRP reinforcing bars in concrete [J].
Aly, Ragi ;
Benmokrane, Brahim ;
Ebead, Usama .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2006, 10 (04) :287-294
[8]  
[Anonymous], 2018, ASTM A370-18
[9]  
[Anonymous], 2008, Guide for the design and construction of externally bonded FRP systems for strengthening concrete structures
[10]  
[Anonymous], 2016, ASTM D7205 / D7205M-06