A Critical Comparison of Comparators Used to Demonstrate Credibility of Physics-Based Numerical Spine Models

被引:1
|
作者
Stott, Brittany [1 ,2 ]
Afshari, Payman [3 ]
Bischoff, Jeff [4 ]
Clin, Julien [5 ]
Francois-Saint-Cyr, Alexandra [6 ]
Goodin, Mark [7 ]
Herrmann, Sven [8 ]
Liu, Xiangui [9 ]
Driscoll, Mark [1 ,2 ]
机构
[1] McGill Univ, Dept Mech Engn, Musculoskeletal Biomech Res Lab, Montreal, PQ H3A 0C3, Canada
[2] Montreal Gen Hosp, Res Inst MUHC, Orthopaed Res Lab, Montreal, PQ H3G 1A4, Canada
[3] Johnson & Johnson, DePuy Synthes Spine, Raynham, MA 02767 USA
[4] Corp Res, Zimmer Biomet, Warsaw, IN 46581 USA
[5] Numalogics Inc, Montreal, PQ H2V 1A2, Canada
[6] Siemens Digital Ind Software, Marlborough, MA 01752 USA
[7] SimuTech Grp Inc, Hudson, OH 44236 USA
[8] CADFEM Med GmbH, D-85567 Grafing, Germany
[9] Stryker Orthopaed, Mahwah, NJ 07430 USA
基金
加拿大自然科学与工程研究理事会;
关键词
Verification; Validation; Uncertainty quantification; Model credibility; Regulatory affairs; Simulation; Virtual patient; FINITE-ELEMENT-ANALYSIS; VALIDATION; VERIFICATION; SENSITIVITY;
D O I
10.1007/s10439-022-03069-x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The ability of new medical devices and technology to demonstrate safety and effectiveness, and consequently acquire regulatory approval, has been dependent on benchtop, in vitro, and in vivo evidence and experimentation. Regulatory agencies have recently begun accepting computational models and simulations as credible evidence for virtual clinical trials and medical device development. However, it is crucial that any computational model undergo rigorous verification and validation activities to attain credibility for its context of use before it can be accepted for regulatory submission. Several recently published numerical models of the human spine were considered for their implementation of various comparators as a means of model validation. The comparators used in each published model were examined and classified as either an engineering or natural comparator. Further, a method of scoring the comparators was developed based on guidelines from ASME V&V40 and the draft guidance from the US FDA, and used to evaluate the pertinence of each comparator in model validation. Thus, this review article aimed to score the various comparators used to validate numerical models of the spine in order to examine the comparator's ability to lend credibility towards computational models of the spine for specific contexts of use.
引用
收藏
页码:150 / 162
页数:13
相关论文
共 50 条
  • [1] A Critical Comparison of Comparators Used to Demonstrate Credibility of Physics-Based Numerical Spine Models
    Brittany Stott
    Payman Afshari
    Jeff Bischoff
    Julien Clin
    Alexandra Francois-Saint-Cyr
    Mark Goodin
    Sven Herrmann
    Xiangui Liu
    Mark Driscoll
    Annals of Biomedical Engineering, 2023, 51 : 150 - 162
  • [2] Functionality and Safety Weaknesses in Integration of Physics-Based Models on Critical Embedded Systems
    Goettlich, Philipp
    Reuss, Hans-Christian
    2019 IEEE 30TH INTERNATIONAL SYMPOSIUM ON SOFTWARE RELIABILITY ENGINEERING WORKSHOPS (ISSREW 2019), 2019, : 67 - 72
  • [3] Model Selection Among Physics-Based Models
    Hombal, V. K.
    Mahadevan, S.
    JOURNAL OF MECHANICAL DESIGN, 2013, 135 (02)
  • [4] Physics-Based Hazard Assessment for Critical Structures Near Large Earthquake Sources
    Hutchings, L.
    Mert, A.
    Fahjan, Y.
    Novikova, T.
    Golara, A.
    Miah, M.
    Fergany, E.
    Foxall, W.
    BEST PRACTICES IN PHYSICS-BASED FAULT RUPTURE MODELS FOR SEISMIC HAZARD ASSESSMENT OF NUCLEAR INSTALLATIONS, 2018, : 311 - 338
  • [5] A comparison between physics-based Li-ion battery models
    Ali, Haider Adel Ali
    Raijmakers, Luc H. J.
    Chayambuka, Kudakwashe
    Danilov, Dmitri L.
    Notten, Peter H. L.
    Eichel, Rudiger-A.
    ELECTROCHIMICA ACTA, 2024, 493
  • [6] Physics-Based Hazard Assessment for Critical Structures Near Large Earthquake Sources
    Hutchings, L.
    Mert, A.
    Fahjan, Y.
    Novikova, T.
    Golara, A.
    Miah, M.
    Fergany, E.
    Foxall, W.
    PURE AND APPLIED GEOPHYSICS, 2017, 174 (09) : 3635 - 3662
  • [7] Power Grid Electromigration Checking Using Physics-Based Models
    Chatterjee, Sandeep
    Sukharev, Valeriy
    Najm, Farid N.
    IEEE TRANSACTIONS ON COMPUTER-AIDED DESIGN OF INTEGRATED CIRCUITS AND SYSTEMS, 2018, 37 (07) : 1317 - 1330
  • [8] Inverse Problems for Physics-Based Process Models
    Bingham, Derek
    Butler, Troy
    Estep, Don
    ANNUAL REVIEW OF STATISTICS AND ITS APPLICATION, 2024, 11 : 461 - 482
  • [9] A Reliable Device Parameter Extraction Scheme for Physics-Based IGBT Models
    Ding, Yifei
    Yang, Xin
    Liu, Guoyou
    IEEE TRANSACTIONS ON ELECTRON DEVICES, 2022, 69 (10) : 5689 - 5697
  • [10] Reconciling the understanding of 'hydrophobicity' with physics-based models of proteins
    Harris, Robert C.
    Pettitt, B. Montgomery
    JOURNAL OF PHYSICS-CONDENSED MATTER, 2016, 28 (08)