Outcomes of repeat transcatheter aortic valve replacement with balloon-expandable valves: a registry study

被引:15
|
作者
Makkar, Raj R. [1 ]
Kapadia, Samir [2 ]
Chakravarty, Tarun [1 ]
Cubeddu, Robert J. [3 ]
Kaneko, Tsuyoshi [4 ]
Mahoney, Paul [5 ]
Patel, Dhairya [1 ]
Gupta, Aakriti [1 ]
Cheng, Wen [1 ]
Kodali, Susheel [6 ]
Bhatt, Deepak L. [7 ]
Mack, Michael J. [8 ]
Leon, Martin B. [6 ]
Thourani, Vinod H. [9 ]
机构
[1] Cedars Sinai Med Ctr, Smidt Heart Inst, Los Angeles, CA 90048 USA
[2] Cleveland Clin, Cleveland, OH USA
[3] Rooney Heart Inst, NCH, Naples, FL USA
[4] Washington Univ, Sch Med, St Louis, MO USA
[5] UPMC Pinnacle Hlth, Harrisburg, PA USA
[6] Columbia Univ, New York, NY USA
[7] Icahn Sch Med Mt Sinai, Mt Sinai Heart, New York, NY USA
[8] Baylor Scott & White Hlth, Dallas, TX USA
[9] Piedmont Heart Inst, Atlanta, GA USA
来源
LANCET | 2023年 / 402卷 / 10412期
关键词
FAILURE MIDTERM OUTCOMES; CORONARY OBSTRUCTION; RISK PATIENTS; REDO-TAVR; STENOSIS; EXPLANT; SOCIETY;
D O I
10.1016/S0140-6736(23)01636-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background With increasing numbers of patients undergoing transcatheter aortic valve replacement (TAVR), data on management of failed TAVR, including repeat TAVR procedure, are needed. The aim of this study was to assess the safety and efficacy of redo-TAVR in a national registry.Methods This study included all consecutive patients in the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry from Nov 9, 2011, to Dec 30, 2022 who underwent TAVR with balloon-expandable valves in failed transcatheter heart valves (redo-TAVR) or native aortic valves (native-TAVR). Procedural, echocardiographic, and clinical outcomes were compared between redo-TAVR and native-TAVR cohorts using propensity score matching.Findings Among 350 591 patients (1320 redo-TAVR; 349 271 native-TAVR), 1320 propensity-matched pairs of patients undergoing redo-TAVR and native-TAVR were analysed (redo-TAVR cohort: mean age 78 years [SD 9]; 559 [42<middle dot>3%] of 1320 female, 761 [57<middle dot>7%] male; mean predicted surgical risk of 30-day mortality 8<middle dot>1%). The rates of procedural complications of redo-TAVR were low (coronary compression or obstruction: four [0<middle dot>3%] of 1320; intraprocedural death: eight [0<middle dot>6%] of 1320; conversion to open heart surgery: six [0<middle dot>5%] of 1319) and similar to native-TAVR. There was no significant difference between redo-TAVR and native-TAVR populations in death at 30 days (4<middle dot>7% vs 4<middle dot>0%, p=0<middle dot>36) or 1 year (17<middle dot>5% vs 19<middle dot>0%, p=0<middle dot>57), and stroke at 30 days (2<middle dot>0% vs 1<middle dot>9%, p=0<middle dot>84) or 1 year (3<middle dot>2% vs 3<middle dot>5%, p=0<middle dot>80). Redo-TAVR reduced aortic valve gradients at 1 year, although they were higher in the redo-TAVR group compared with the native-TAVR group (15 mm Hg vs 12 mm Hg; p<0<middle dot>0001). Moderate or severe aortic regurgitation rates were similar between redo-TAVR and native-TAVR groups at 1 year (1<middle dot>8% vs 3<middle dot>3%, p=0<middle dot>18). Death or stroke after redo-TAVR were not significantly affected by the timing of redo-TAVR (before or after 1 year of index TAVR), or by index transcatheter valve type (balloon-expandable or non-balloon-expandable).Interpretation Redo-TAVR with balloon-expandable valves effectively treated dysfunction of the index TAVR procedure with low procedural complication rates, and death and stroke rates similar to those in patients with a similar clinical profile and predicted risk undergoing TAVR for native aortic valve stenosis. Redo-TAVR with balloon-expandable valves might be a reasonable treatment for failed TAVR in selected patients.
引用
收藏
页码:1529 / 1540
页数:12
相关论文
共 50 条
  • [1] Impact of Tricuspid Regurgitation on Outcomes of Transcatheter Aortic Valve Replacement With Balloon-Expandable Valves
    Zahr, Firas
    Elmariah, Sammy
    Vemulapalli, Sreekanth
    Kodali, Susheel K.
    Hahn, Rebecca T.
    Anderson, Allen S.
    Eleid, Mackram F.
    Davidson, Charles J.
    Sharma, Rahul P.
    O'Neill, William W.
    Bethea, Brian
    Thourani, Vinod H.
    Chakravarty, Tarun
    Gupta, Aakriti
    Makkar, Raj R.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2024, 17 (16) : 1916 - 1931
  • [2] Transcatheter Pulmonary Valve Replacement With Balloon-Expandable Valves Utilization and Procedural Outcomes From the IMPACT Registry
    Schmidt, Ada C. Stefanescu
    Armstrong, Aimee K.
    Aboulhosn, Jamil A.
    Kennedy, Kevin F.
    Jones, Thomas K.
    Levi, Daniel S.
    Mcelhinney, Doff B.
    Bhatt, Ami B.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2024, 17 (02) : 231 - 244
  • [3] Balloon-Expandable Prostheses for Transcatheter Aortic Valve Replacement
    Ribeiro, Henrique Barbosa
    Urena, Marina
    Allende, Ricardo
    Amat-Santos, Ignacio J.
    Rodes-Cabau, Josep
    PROGRESS IN CARDIOVASCULAR DISEASES, 2014, 56 (06) : 583 - 595
  • [4] Transcatheter Valve-In-Valve Implantation for Failed Balloon-Expandable Transcatheter Aortic Valves
    Toggweiler, Stefan
    Wood, David A.
    Rodes-Cabau, Josep
    Kapadia, Samir
    Willson, Alexander B.
    Ye, Jian
    Cheung, Anson
    Leipsic, Jonathon
    Binder, Ronald K.
    Gurvitch, Ronen
    Freeman, Melanie
    Thompson, Christopher R.
    Svensson, Lars G.
    Dumont, Eric
    Tuzcu, E. Murat
    Webb, John G.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2012, 5 (05) : 571 - 577
  • [5] Optimizing Valve Sizing in Balloon-Expandable Transcatheter Aortic Valve Replacement
    Krishnaswamy, Amar
    Kapadia, Samir R.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2018, 11 (17) : 1706 - 1709
  • [6] Outcomes After Transcatheter Aortic Valve Replacement With Balloon-Expandable Versus Self-Expandable Valves CHOICE Trial Results
    Montone, Rocco A.
    Testa, Luca
    Bedogni, Francesco
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 67 (02) : 235 - 236
  • [8] Comparative meta-analysis of balloon-expandable and self-expandable valves for transcatheter aortic valve replacement
    Agarwal, Shikhar
    Parashar, Akhil
    Kumbhani, Dharam J.
    Svensson, Lars G.
    Krishnaswamy, Amar
    Tuzcu, E. Murat
    Kapadia, Samir R.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2015, 197 : 87 - 97
  • [9] BALLOON-EXPANDABLE VERSUS SELF-EXPANDABLE TRANSCATHETER AORTIC VALVE REPLACEMENT
    Okumura, L.
    Sanchez, L.
    Alves, M.
    Candolfi, P.
    VALUE IN HEALTH, 2021, 24 : S68 - S68
  • [10] Balloon-Expandable Versus Self-Expandable Valve in Transcatheter Aortic Valve Replacement: A NationWide Study
    Sa, Young Kyoung
    Choi, Ik Jun
    Chang, Kiyuk
    Hwang, Byung-Hee
    Chung, Woo-Baek
    Lee, Kwan Yong
    Choo, Eun-Ho
    Kim, Chan Joon
    Park, Mahn Won
    Choi, Yoon Seok
    Park, Chul Soo
    Yoo, Ki Dong
    Jeon, Doo Soo
    Oak, Min -Ho
    Lee, Jungkuk
    Kang, Dongwoo
    AMERICAN JOURNAL OF CARDIOLOGY, 2024, 213 : 119 - 125