Synergetic control for three-level voltage source inverter-based shunt active power filter to improve power quality

被引:25
作者
Deffaf, Brahim [1 ]
Farid, Hamoudi [1 ]
Benbouhenni, Habib [2 ]
Medjmadj, Slimane [3 ,4 ]
Debdouche, Naamane [5 ]
机构
[1] Univ Bejaia, Fac Technol, Lab Maitrise Energies Renouvelables LMER, Bejaia 06000, Algeria
[2] Nisantasi Univ, Fac Engn & Architecture, Dept Elect & Elect Engn, Istanbul, Turkiye
[3] Univ Set, Lab Control, Setif, Algeria
[4] Univ Bordj Bou Arreridj, El Anceur, Algeria
[5] Univ Freres Mentouri Constantine 1, Lab Electrotech Constantine LEC, Constantine, Algeria
关键词
Three levels neutral point clamped; Synergetic control; Power quality; Shunt active power filter; Proportional-integral controller; SPACE-VECTOR MODULATION; SLIDING MODE CONTROL; PWM; SYSTEMS; IMPLEMENTATION; OPTIMIZATION; ELIMINATION; DESIGN;
D O I
10.1016/j.egyr.2023.07.051
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The present paper proposes a synergetic control (SC) with Phase-Locked Loop (PLL) technique for a three-phase three-levels neutral point clamped-voltage source inverter-based shunt active power filter (SAPF). This one is devoted to compensating for nonlinear load harmonics and reactive power to improve power quality in distribution power systems. SC strategy is known as a robust control with good performances in transient and steady-state performance. Furthermore, it does not require solving the state equations, nor knowing the poles of the system. The DC voltage, as well as the active filter currents, are controlled using SC strategies. The efficiency of the suggested strategy has been verified through simulation tests using Matlab/Simulink software, where the simulation results are analyzed for two scenarios: a diode bridge rectifier with RL load and RC load. The active power filter demonstrated outstanding performance in reducing harmonics, maintaining a dynamic response, and tracking DC voltage for both RL and RC loads, as revealed by the simulation results. By comparing the suggested control with the traditional control, we found that the former outperforms the latter in all aspects. This sheds light on the effectiveness of the suggested control. & COPY; 2023 The Authors. Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页码:1013 / 1027
页数:15
相关论文
共 90 条
[31]   A laboratory application for teaching the effect of harmonics on transformer core saturation [J].
Donuk, Atilla .
INTERNATIONAL JOURNAL OF ELECTRICAL ENGINEERING EDUCATION, 2020, 57 (03) :191-201
[32]   Modified CCF Based Shunt Active Power Filter Operation With Dead-Band Elimination for Effective Harmonic and Unbalance Compensation in 3-Phase 3-Wire System [J].
Dubey, Alok Kumar ;
Mishra, Jyoti Prakash ;
Kumar, Amritesh .
IEEE TRANSACTIONS ON POWER DELIVERY, 2022, 37 (03) :2131-2142
[33]   Harmonic Mitigation Using Meta-Heuristic Optimization for Shunt Adaptive Power Filters: A Review [J].
Duc, Minh Ly ;
Hlavaty, Lukas ;
Bilik, Petr ;
Martinek, Radek .
ENERGIES, 2023, 16 (10)
[34]   Optimal design of controllers and harmonic compensators for three-level cascaded control in stationary reference frame for grid-supporting inverters-based AC microgrid [J].
Ebrahim, Mohamed A. ;
Aziz, Beshoy Abdou ;
Nashed, Maged N. F. ;
Osman, F. A. .
ENERGY REPORTS, 2022, 8 :860-877
[35]   Research on three-phase VSR segmented PI synergetic control strategy based on LCL filter [J].
Gao, Weishi ;
Yan, Yunbing ;
Ma, Qiang ;
Wang, Xiaodong ;
Zhu, Bowen .
IET CIRCUITS DEVICES & SYSTEMS, 2021, 15 (04) :377-387
[36]  
Gasmi H., 2023, IRAN J ELECT ELECT E, V19, P2431, DOI [10.22068/IJEEE.19.2.2431, DOI 10.22068/IJEEE.19.2.2431]
[37]   Fractional-order proportional-integral super twisting sliding mode controller for wind energy conversion system equipped with doubly fed induction generator [J].
Gasmi, Hamza ;
Mendaci, Sofiane ;
Laifa, Sami ;
Kantas, Walid ;
Benbouhenni, Habib .
JOURNAL OF POWER ELECTRONICS, 2022, 22 (08) :1357-1373
[38]   A Robust Second-Order Sliding Mode Control for Single-Phase Photovoltaic Grid-Connected Voltage Source inverter [J].
Guo, Bin ;
Su, Mei ;
Sun, Yao ;
Wang, Hui ;
Dan, Hanbing ;
Tang, Zhongting ;
Cheng, Bin .
IEEE ACCESS, 2019, 7 :53202-53212
[39]  
Habib B., 2021, J ELECT ENG ELECT CO, V7
[40]  
Habib B., 2022, Int. J. Smart Grid-ijSmartGrid, V6, P144, DOI [10.20508/ijsmartgrid.v6i4.265.g251, DOI 10.20508/IJSMARTGRID.V6I4.265.G228, 10.20508/ijsmartgrid.v6i4.265.g228]