Direct analysis in real-time mass spectrometry: Observations of helium, nitrogen and argon as ionisation gas for the detection of small molecules using a single quadrupole instrument

被引:6
作者
Mathias, Simone [1 ]
Sears, Patrick [1 ,2 ]
机构
[1] Univ Surrey, Sch Chem & Chem Engn, Guildford, England
[2] Univ Surrey, Sch Chem & Chem Engn, Guildford GU2 7XH, England
基金
英国工程与自然科学研究理事会;
关键词
DART-MS; EXPLOSIVES; MECHANISM; DRUGS; TOOL;
D O I
10.1002/rcm.9521
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
RationaleDirect analysis in real time is typically performed using helium as the ionisation gas for the detection of analytes by mass spectrometry (MS). Nitrogen and argon are found with abundance in the air and provide a cheaper and greener alternative to the use of helium as ionisation gas. This study explores the use of helium, nitrogen and argon as ionisation gas for the detection of organic compounds. MethodsFour illicit drugs, two amino acids and five explosives were chosen as target analytes to understand selectivity, sensitivity and linearity when helium, nitrogen or argon was used as the ionisation gas with the direct analysis in real time (DART) source. Analysis was carried out on a Waters Acquity QDa single quadrupole mass spectrometer. ResultsCalibration curves over the range of 5-100 ng were produced for each analyte using the different ionisation gases to assess the instrument response. Nitrogen gave a higher response to concentration than helium or argon; however, the lowest limits of detection were observed when helium was used. ConclusionsAll the target analytes were detected using DART-MS with helium, nitrogen or argon as the ionisation gas. Whereas helium provided the highest sensitivity, nitrogen produced reasonable limits of detection and had good linearity across the concentration range explored, suggesting it provides a greener and cheaper alternative to helium.
引用
收藏
页数:8
相关论文
共 36 条
[1]   Nitrogen-Activated Oxidation in Nitrogen Direct Analysis in Real Time Mass Spectrometry (DART-MS) and Rapid Detection of Explosives Using Thermal Desorption DART-MS [J].
An, ShuQi ;
Liu, Shuai ;
Cao, Jie ;
Lu, ShiFang .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2019, 30 (10) :2092-2100
[2]   Mass Spectrometry for Trace Analysis of Explosives in Water [J].
Badjagbo, Koffi ;
Sauve, Sebastien .
CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 2012, 42 (03) :257-271
[3]   The current and potential applications of Ambient Mass Spectrometry in detecting food fraud [J].
Black, Connor ;
Chevallier, Olivier P. ;
Elliott, Christopher T. .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2016, 82 :268-278
[4]   Direct Analysis in Real Time (DART) and a portable mass spectrometer for rapid identification of common and designer drugs on-site [J].
Brown, Hilary ;
Oktem, Berk ;
Windom, Ashley ;
Doroshenko, Vladimir ;
Evans-Nguyen, Kenyon .
FORENSIC CHEMISTRY, 2016, 1 :66-73
[5]   Ambient ionisation mass spectrometry for the trace detection of explosives using a portable mass spectrometer [J].
Burns, Daniel ;
Mathias, Simone ;
McCullough, Bryan J. ;
Hopley, Chris J. ;
Douce, David ;
Lumley, Nicola ;
Bajic, Steve ;
Sears, Patrick .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2022, 471
[6]   Atmospheric pressure solid analysis probe coupled to quadrupole-time of flight mass spectrometry as a tool for screening and semi-quantitative approach of polycyclic aromatic hydrocarbons, nitro-polycyclic aromatic hydrocarbons and oxo-polycyclic aromatic hydrocarbons in complex matrices [J].
Carrizo, Daniel ;
Domeno, Celia ;
Nerin, Isabel ;
Alfaro, Pilar ;
Nerin, Cristina .
TALANTA, 2015, 131 :175-184
[7]   Assessment of direct analysis in real time accurate mass spectrometry for the determination of triclosan in complex matrices [J].
Cobo-Golpe, M. ;
Garcia-Martin, J. ;
Ramil, M. ;
Cela, R. ;
Rodriguez, I. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2021, 413 (25) :6355-6364
[8]   Versatile new ion source for the analysis of materials in open air under ambient conditions [J].
Cody, RB ;
Laramée, JA ;
Durst, HD .
ANALYTICAL CHEMISTRY, 2005, 77 (08) :2297-2302
[9]  
Cody RB., 2014, NEW DEV NMR, V1st ed., P30, DOI [10.1039/978178262802600023, DOI 10.1039/9781782628026]
[10]   Aperture Size Influences Oxidation in Positive-Ion Nitrogen Direct Analysis in Real Time Mass Spectrometry [J].
Cody, Robert B. .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2022, 33 (07) :1329-1334