Usefulness and Reliability of the Bispectral Index during Balanced Anesthesia for Neurovascular Surgery in New Zealand White Rabbits

被引:0
作者
Petrucci, Mariafrancesca [1 ]
Spadavecchia, Claudia [2 ]
Wanderer, Stefan [3 ,4 ]
Boillat, Gwendoline [3 ,4 ]
Marbacher, Serge [3 ,4 ]
Casalta, Luisana Gisela Garcia [1 ]
Casoni, Daniela [1 ]
机构
[1] Univ Bern, Fac Med, Dept Biomed Res, Expt Surg Facil ESF, CH-3010 Bern, Switzerland
[2] Univ Bern, Vetsuisse Fac, Dept Clin Vet Med, Anesthesiol & Pain Therapy Sect, CH-3012 Bern, Switzerland
[3] Kantonsspital Aarau, Dept Neurosurg, CH-5001 Aarau, Switzerland
[4] Univ Bern, Dept Biomed Res, Cerebrovasc Res Grp, CH-3010 Bern, Switzerland
关键词
bispectral index; balanced anesthesia; neuromonitoring; neurosurgery; rabbits; fentanyl; carotid bifurcation; experimental anesthesia; NERVOUS-SYSTEM DEPRESSION; INTENSIVE-CARE-UNIT; NOXIOUS-STIMULATION; PROPOFOL ANESTHESIA; GENERAL-ANESTHESIA; DEPTH; ISOFLURANE; KETAMINE; ELECTROENCEPHALOGRAM; LIDOCAINE;
D O I
10.3390/brainsci13020327
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Few data about the electroencephalogram and its calculated indices, such as the bispectral index (BIS), have been reported in rabbits. We aimed to evaluate whether a clinically stable anesthesia was mirrored by consistent and stable BIS values and to investigate the effects of modified cerebral blood supply, due to bilateral carotid clamping and re-opening, on BIS values. We also investigated the effects of fentanyl, as an antinociceptive drug, on the BIS. Sixty-eight rabbits undergoing general anesthesia for surgical creation of carotid bifurcation aneurysms were enrolled. The BIS values were recorded at nine selected time points (TPs) during each procedure and before and after fentanyl administration. The BIS values over time were compared with two-way repeated-measures analysis of variance followed by Tukey test, while the Wilcoxon signed rank test was performed to compare values at clamping and re-opening of the carotids as well as before and after fentanyl administration. The BIS values were significantly lower during anesthesia than at the end of anesthesia and at tracheal extubation; no significant differences were found among other TPs. Adequate depth of anesthesia was mirrored by consistent BIS values among rabbits, and alteration of cerebral blood supply did not modify BIS values, except once. Following fentanyl, BIS values did not change in a clinically relevant way.
引用
收藏
页数:14
相关论文
共 57 条
  • [1] Isoflurane anaesthetic depth in goats monitored using the bispectral index of the electroencephalogram
    Antognini, JF
    Wang, XW
    Carstens, E
    [J]. VETERINARY RESEARCH COMMUNICATIONS, 2000, 24 (06) : 361 - 370
  • [2] Bard J W, 2001, AANA J, V69, P477
  • [3] The effect of intravenous lidocaine infusion on bispectral index during major abdominal surgery
    Bazin, Patrick
    Padley, James
    Ho, Matthew
    Stevens, Jennifer
    Ben-Menachem, Erez
    [J]. JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2018, 32 (03) : 533 - 539
  • [4] Anatomical Variations of the Common Carotid Arteries and Neck Structures of the New Zealand White Rabbit and Their Implications for the Development of Preclinical Extracranial Aneurysm Models
    Boillat, Gwendoline
    Franssen, Tim
    Wanderer, Stefan
    Rey, Jeannine
    Casoni, Daniela
    Andereggen, Lukas
    Marbacher, Serge
    Gruter, Basil E. E.
    [J]. BRAIN SCIENCES, 2023, 13 (02)
  • [5] Bispectral Index profile during carotid cross clamping
    Bonhomme, Vincent
    Desiron, Quentin
    Lemineur, Thierry
    Brichant, Jean Francois
    Dewandre, Pierre-Yves
    Hans, Pol
    [J]. JOURNAL OF NEUROSURGICAL ANESTHESIOLOGY, 2007, 19 (01) : 49 - 55
  • [6] Does using the bispectral index (BIS) during craniotomy affect the quality of recovery?
    Boztug, N
    Bigat, Z
    Akyuz, M
    Demir, S
    Ertok, E
    [J]. JOURNAL OF NEUROSURGICAL ANESTHESIOLOGY, 2006, 18 (01) : 1 - 4
  • [7] Bispectral index variations during tracheal suction in mechanically ventilated critically ill patients: effect of an alfentanil bolus
    Brocas, E
    Dupont, H
    Paugam-Burtz, C
    Servin, F
    Mantz, J
    Desmonts, JM
    [J]. INTENSIVE CARE MEDICINE, 2002, 28 (02) : 211 - 213
  • [8] Depth of anaesthesia monitoring: what's available, what's validated and what's next?
    Bruhn, J.
    Myles, P. S.
    Sneyd, R.
    Struys, M. M. R. F.
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2006, 97 (01) : 85 - 94
  • [9] Electromyographic activity falsely elevates the bispectral index
    Bruhn, J
    Bouillon, TW
    Shafer, SL
    [J]. ANESTHESIOLOGY, 2000, 92 (05) : 1485 - 1487
  • [10] Use of bispectral index to monitor depth of anesthesia in isoflurane-anesthetized dogs
    Campagnol, Daniela
    Teixeira Neto, Francisco J.
    Monteiro, Eduardo R.
    Beier, Suzane L.
    Aguiar, Antonio J. A.
    [J]. AMERICAN JOURNAL OF VETERINARY RESEARCH, 2007, 68 (12) : 1300 - 1307