Suspensory Device Fixation of Lisfranc Injuries in a Southeast Asian Urban Population: Patient-Reported Functional Outcomes

被引:0
作者
Tan, Yong-Yao [1 ]
Low, Yi-Mei [1 ]
Socklingam, Raj Kumar [2 ]
Chandrakumara, S. B. M. Darshana
Kon, Charles [1 ]
机构
[1] Changi Gen Hosp, Orthopaed Surg, Singapore, Singapore
[2] Changi Gen Hosp, Orthopaed, Singapore, Singapore
关键词
sport injury; trauma; suture button; suspensory fixation; foot; orthopaedic; lisfranc; INTERNAL-FIXATION; OPEN REDUCTION; FRACTURE-DISLOCATIONS; PRIMARY ARTHRODESIS; JOINT INJURIES;
D O I
10.7759/cureus.46629
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction Open reduction internal fixation (ORIF) and primary arthrodesis are two conventional options for the treatment of Lisfranc injuries. However, they are associated with implant-related complications. An alternative suspensory device construct using interosseous nonabsorbable sutures with endobuttons has been described with satisfactory results. This study aims to explore functional outcomes after suture button fixation of Lisfranc injuries in a Southeast Asian population. Methods This was a single-surgeon retrospective study of patients with Lisfranc injuries treated surgically using a suture button fixation technique between 2017 and 2019. Data collected included demographic information, pre-injury levels of activity, nature of injury, and type of surgery performed. The minimum postoperative follow-up was one year. The Foot and Ankle Outcome Score (FAOS) and Foot and Ankle Ability Measure (FAAM) were used to evaluate patient-reported outcomes. Scores were reported in percentage (%) with median and interquartile range. Results Twenty-nine patients with a mean age of 29 years (21-76) were recruited. Sixteen underwent suture button fixation only (SB), and 13 underwent suture button fixation with intercuneiform screw fixation and plating (SBM). The median scores for the FAOS and FAAM questionnaires were at least 80% in all domains. Twenty-eight patients (97%) were able to return to pre-injury activity level, 27 patients (93%) were able to return to sports. Only one patient was not satisfied with the outcomes of surgery. No patients had post-traumatic arthritis or hardware failure necessitating implant removal at the final follow-up. Conclusion This study has demonstrated that treatment of Lisfranc injuries with a suspensory device construct resulted in good outcomes with 97% of patients being able to return to pre-injury activity levels, and 93% of patients being able to return to sports. It may not be necessary to perform primary arthrodesis in uncomplicated Lisfranc injuries. This technique is also advantageous as implant removal is not routinely required due to the design and biomechanical properties of suspensory devices.
引用
收藏
页数:9
相关论文
共 21 条
  • [1] Ligamentous Lisfranc joint injuries: A biomechanical comparison of dorsal plate and transarticular screw fixation
    Alberta, FG
    Aronow, MS
    Barrero, M
    Diaz-Doran, V
    Sullivan, RJ
    Adams, DJ
    [J]. FOOT & ANKLE INTERNATIONAL, 2005, 26 (06) : 462 - 473
  • [2] Primary Arthrodesis versus Open Reduction and Internal Fixation for Low-Energy Lisfranc Injuries in a Young Athletic Population
    Cochran, Grant
    Renninger, Christopher
    Tompane, Trevor
    Bellamy, Joseph
    Kuhn, Kevin
    [J]. FOOT & ANKLE INTERNATIONAL, 2017, 38 (09) : 957 - 963
  • [3] Treatment of Lisfranc fracture dislocations with an interosseous suture button technique: A review of 3 cases
    Cottom, James M.
    Hyer, Christopher F.
    Berlet, Gregory C.
    [J]. JOURNAL OF FOOT & ANKLE SURGERY, 2008, 47 (03) : 250 - 258
  • [4] MR Imaging Evaluation of Subtle Lisfranc Injuries: The Midfoot Sprain
    Crim, Julia
    [J]. MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2008, 16 (01) : 19 - +
  • [5] Current concepts review: Lisfranc injuries
    Desmond, Elizabeth A.
    Chou, Loretta B.
    [J]. FOOT & ANKLE INTERNATIONAL, 2006, 27 (08) : 653 - 660
  • [6] The surgical outcome of Lisfranc injuries accompanied by multiple metatarsal fractures: A multicenter retrospective study
    Fan, Meng-Qiang
    Li, Xu-Song
    Jiang, Xian-Jun
    Shen, Jian-Jian
    Tong, Pei-Jian
    Huang, Jie-Feng
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2019, 50 (02): : 571 - 578
  • [7] Open Reduction Internal Fixation Versus Primary Arthrodesis for Lisfranc Injuries: A Prospective Randomized Study
    Henning, Jeffrey A.
    Jones, Clifford B.
    Sietsema, Debra L.
    Bohay, Donald R.
    Anderson, John G.
    [J]. FOOT & ANKLE INTERNATIONAL, 2009, 30 (10) : 913 - 922
  • [8] InternalBrace has biomechanical properties comparable to suture button but less rigid than screw in ligamentous lisfranc model
    Hopkins, Justin
    Nguyen, Kevin
    Heyrani, Nasser
    Shelton, Trevor
    Kreulen, Christopher
    Garcia-Nolen, Tanya
    Christiansen, Blaine A.
    Giza, Eric
    [J]. JOURNAL OF ORTHOPAEDICS, 2020, 17 : 7 - 12
  • [9] Dorsal bridge plating or transarticular screws for Lisfranc fracture dislocations A RETROSPECTIVE STUDY COMPARING FUNCTIONAL AND RADIOLOGICAL OUTCOMES
    Kirzner, N.
    Zotov, P.
    Goldbloom, D.
    Curry, H.
    Bedi, H.
    [J]. BONE & JOINT JOURNAL, 2018, 100B (04) : 468 - 474
  • [10] Outcome after open reduction and internal fixation of Lisfranc joint injuries
    Kuo, RS
    Tejwani, NC
    DiGiovanni, CW
    Holt, SK
    Benirschke, SK
    Hansen, ST
    Sangeorzan, BJ
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (11) : 1609 - 1618