In-vitro experiments on bio-functional calcium phosphate based coatings on titanium dental implant

被引:1
作者
Balamurugan, P. [1 ]
Selvakumar, N. [1 ]
机构
[1] Mepco Schlenk Engn Coll, Dept Mech Engn, Sivakasi 6260005, Tamil Nadu, India
关键词
Dental implant; Magnetron sputtering; Bioactive materials; Biocompatibility; in-vitro; OSSEOINTEGRATION; ANTIBACTERIAL; SURFACE; ADHESION;
D O I
10.1088/2053-1591/ace02a
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Dental implants are a revolution in dentistry, but certain deficiencies still need to be addressed. One of the most severe threats to the success of dental implants is peri-implant infection. Existing coatings on titanium (Ti-6Al-4V) alloy surfaces rapidly lose antibacterial efficacy, reducing their ability to prevent peri-implant infectious disease. The objective of this paper was to investigate the dissolution capabilities and film properties of calcium phosphate (CaP) based layers on a titanium (Ti-6Al-4V) alloy surface produced with the radiofrequency magnetron sputtering method. These coatings have demonstrated good osseointegration capability due to their similarity to bone mineral matter. The bioactive coating materials are calcium phosphate, zinc chloride, and silver nitrate. Microstructural investigations of coated components were assessed using Fourier Transform Infrared Spectroscopy (FTIR), Scanning Electron Microscopy (SEM), Energy Dispersive (EDX) analysis, and Atomic Force Microscopy (AFM). Bacterial adhesion to biomaterials is still a major issue when it comes to medical equipment. Antimicrobial peptides have generated interest due to the rise in antibiotic-resistant bacteria. The fact that there are concerns regarding the development of antibiotic resistance due to the development of traditional antibiotics to prevent illness reflects the complexity of the matter.The coated titanium samples were inoculated in nutrient broth and incubated at 37 & DEG;C for 24 h. The samples were tested against Staphylococcus aureus and Staphylococcus epidermidis for 72 h. A standard row containing between 1 * 10(5) CFU ml(-1) and 1 * 10(7) CFU ml(-1)of fresh exponential culture was prepared. The plates were cultured at 37 & DEG;C and shaken (100 rpm) while the OD600 was monitored every 30 min. After 24 h, Staphylococcus aureus inhibition was higher than 70% in S4, and Staphylococcus epidermidis inhibition ranged from 60 to 70% in S4. Antimicrobial activity was found in the calcium phosphate coated samples (S4) against gram-positive Staphylococcus epidermidis and Staphylococcus aureus bacteria. The antimicrobial evaluation showed that titanium made with bioactive coating inhibited bacterial growth and biofilm formation.
引用
收藏
页数:14
相关论文
共 36 条
[1]   Antibacterial and bioactive coatings on titanium implant surfaces [J].
Aranya, Anupama Kulkarni ;
Pushalkar, Smruti ;
Zhao, Minglei ;
LeGeros, Racquel Z. ;
Zhang, Yu ;
Saxena, Deepak .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2017, 105 (08) :2218-2227
[2]   Osseointegration properties of titanium dental implants modified with a nanostructured coating based on ordered porous silica and bioactive glass nanoparticles [J].
Covarrubias, Cristian ;
Mattmann, Matias ;
Von Marttens, Alfredo ;
Caviedes, Pablo ;
Arriagada, Cristian ;
Valenzuela, Francisco ;
Pablo Rodriguez, Juan ;
Corral, Camila .
APPLIED SURFACE SCIENCE, 2016, 363 :286-295
[3]   In vivo osseointegration of Ti implants with a strontium-containing nanotubular coating [J].
Dang, Yonggang ;
Zhang, Li ;
Song, Wen ;
Chang, Bei ;
Han, Tianxiao ;
Zhang, Yumei ;
Zhao, Lingzhou .
INTERNATIONAL JOURNAL OF NANOMEDICINE, 2016, 11 :1003-1011
[4]   Si-doped porous TiO2 coatings enhanced in vitro angiogenic behavior of human umbilical vein endothelial cells [J].
Ding, Zhihong ;
Qiao, Yuqin ;
Peng, Feng ;
Xia, Chao ;
Qian, Shi ;
Wang, Tao ;
Sun, Junying ;
Liu, Xuanyong .
COLLOIDS AND SURFACES B-BIOINTERFACES, 2017, 159 :493-500
[5]   Surface Modified Techniques and Emerging Functional Coating of Dental Implants [J].
Dong, Heng ;
Liu, Hui ;
Zhou, Na ;
Li, Qiang ;
Yang, Guangwen ;
Chen, Li ;
Mou, Yongbin .
COATINGS, 2020, 10 (11) :1-25
[6]   Biomimetic in vitro test system for evaluation of dental implant materials [J].
Ehlicke, Franziska ;
Berndt, Jonathan ;
Marichikj, Nina ;
Steinmueller-Nethl, Doris ;
Walles, Heike ;
Berndt, Ernst-Ulrich ;
Hansmann, Jan .
DENTAL MATERIALS, 2020, 36 (08) :1059-1070
[7]   Antibacterial ability, cytocompatibility and hemocompatibility of fluorinated graphene [J].
Geng, Hao ;
Wang, Tianbo ;
Cao, Huiliang ;
Zhu, Hongqin ;
Di, Zengfeng ;
Liu, Xuanyong .
COLLOIDS AND SURFACES B-BIOINTERFACES, 2019, 173 :681-688
[8]   Bioactive calcium phosphate silicate ceramic surface-modified PLGA for tendon-to-bone healing [J].
Guo, Jingshu ;
Ning, Congqin ;
Liu, Xuanyong .
COLLOIDS AND SURFACES B-BIOINTERFACES, 2018, 164 :388-395
[9]  
Honda M., 2017, INT J METALLURGICAL, V3, P1
[10]   Development of a Surface-Functionalized Titanium Implant for Promoting Osseointegration: Surface Characteristics, Hemocompatibility, and In Vivo Evaluation [J].
Hou, Ping-Jen ;
Syam, Syamsiah ;
Lan, Wen-Chien ;
Ou, Keng-Liang ;
Huang, Bai-Hung ;
Chan, Ka-Chun ;
Tsai, Chi-Hsun ;
Saito, Takashi ;
Liu, Chung-Ming ;
Chou, Hsin-Hua ;
Huang, Yueh-Tzu ;
Fa, Fang-Yu .
APPLIED SCIENCES-BASEL, 2020, 10 (23) :1-10