Home Monitoring of Glaucoma Using a Home Tonometer and a Novel Virtual Reality Visual Field Device Acceptability and Feasibility

被引:19
作者
Hu, Galen Y. [1 ,2 ]
Prasad, Jaideep [1 ,3 ]
Chen, Dinah K. [3 ]
Alcantara-Castillo, Jennifer C. [3 ]
Patel, Vipul N. [2 ]
Al-Aswad, Lama A. [2 ,3 ,4 ]
机构
[1] NYU, Grossman Sch Med, New York, NY USA
[2] New York Univ Langone Hlth, Dept Populat Hlth, New York, NY USA
[3] New York Univ Langone Hlth, Dept Ophthalmol, New York, NY USA
[4] NYU Langone Hlth, Dept Ophthalmol, 222 E 41st St,4th Floor, New York, NY 10017 USA
来源
OPHTHALMOLOGY GLAUCOMA | 2023年 / 6卷 / 02期
关键词
Digital health; Glaucoma; Home monitoring; Rebound tonometry; Virtual reality; SERVICE COVERAGE ANALYSIS; OPEN-ANGLE GLAUCOMA; PROGRESSION; ADHERENCE; PRESSURE; CARE;
D O I
10.1016/j.ogla.2022.05.001
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective: Our aim was to assess the acceptability and feasibility of iCare HOME tonometer (HT) and Virtual Field (VF) devices in the home monitoring of glaucoma. Design: Prospective feasibility and acceptability study. Subjects: Twenty patients (39 eyes) with primary open-angle glaucoma, open-angle glaucoma, ocular hypertension, or suspected glaucoma. Methods: Patients were trained and instructed to bring 2 devices home for 1 week and use the HT 4 times/ day for 4 days and the VF 3 times total. Main Outcome Measures: For acceptability, we conducted satisfaction surveys and semistructured, qualitative interviews with a thematic analysis. Feasibility was assessed by device usage and quality of tests. Results: Most patients (73.7%) felt that the HT was easy to use, and 100% of them found the HT useful. All patients (100%) felt that VF was easy to use, and 94.4% of them found the VF useful. All patients (100%) obtained acceptable intraocular pressure and completed a VF test at home. We identified 4 key themes, with 33 subthemes. The key themes include the following: (1) advantages of home monitoring; (2) difficulties with home monitoring; (3) future considerations in home monitoring; and (4) the experience of patients with glaucoma. Conclusions: The HT and VF were acceptable and feasible in a small cohort of motivated subjects. Patients were able to perform these tests proficiently at home, and they were generally enthused to obtain more data about their intraocular health, as it allowed them a heightened sense of security and insight about their chronic disease, as well as a reduction in foreseeable barriers to care. Home monitoring may also improve upon glaucoma care by enhancing patient empowerment and fostering community bonds. The VF should be further evaluated to ensure validity. Financial Disclosure(s): Proprietary or commercial disclosure may be found after the references. Ophthalmology Glaucoma 2023;6:121-128 (c) 2022 by the American Academy of Ophthalmology
引用
收藏
页码:121 / 128
页数:8
相关论文
共 34 条
[21]  
Leske MC, 2003, ARCH OPHTHALMOL-CHIC, V121, P48
[22]   Icare Home Tonometer: A Review of Characteristics and Clinical Utility [J].
Liu, John ;
De Francesco, Ticiana ;
Schlenker, Matthew ;
Ahmed, Iqbal Ike .
CLINICAL OPHTHALMOLOGY, 2020, 14 :4031-4045
[23]   Visual Field Testing with Head-Mounted Perimeter 'imo' [J].
Matsumoto, Chota ;
Yamao, Sayaka ;
Nomoto, Hiroki ;
Takada, Sonoko ;
Okuyama, Sachiko ;
Kimura, Shinji ;
Yamanaka, Kenzo ;
Aihara, Makoto ;
Shimomura, Yoshikazu .
PLOS ONE, 2016, 11 (08)
[24]   Validation of a Head-mounted Virtual Reality Visual Field Screening Device [J].
Mees, Lukas ;
Upadhyaya, Swati ;
Kumar, Pavan ;
Kotawala, Sandal ;
Haran, Shankar ;
Rajasekar, Shruthi ;
Friedman, David S. ;
Venkatesh, Rengaraj .
JOURNAL OF GLAUCOMA, 2020, 29 (02) :86-91
[25]   The behaviour change wheel: A new method for characterising and designing behaviour change interventions [J].
Michie, Susan ;
van Stralen, Maartje M. ;
West, Robert .
IMPLEMENTATION SCIENCE, 2011, 6
[26]   A Survey of Glaucoma Surgery Practice Patterns in the Veterans Health Administration [J].
Olivieri, Daniel J. ;
Lynch, Mary G. ;
Cockerham, Glenn C. ;
Greenberg, Paul B. .
MILITARY MEDICINE, 2020, 185 (7-8) :E972-E976
[27]   The number of people with glaucoma worldwide in 2010 and 2020 [J].
Quigley, HA ;
Broman, AT .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2006, 90 (03) :262-267
[28]   The economic burden of major adult visual disorders in the United States [J].
Rein, David B. ;
Zhang, Ping ;
Wirth, Kathleen E. ;
Lee, Paul P. ;
Hoerger, Thomas J. ;
McCall, Nancy ;
Klein, Ronald ;
Tielsch, James M. ;
Vijan, Sandeep ;
Saaddine, Jinan .
ARCHIVES OF OPHTHALMOLOGY, 2006, 124 (12) :1754-1760
[29]   A Geodemographic Service Coverage Analysis of Travel Time to Glaucoma Specialists in Florida [J].
Rothman, Adam L. ;
Stoler, Justin B. ;
Vu, Daniel M. ;
Chang, Ta C. .
JOURNAL OF GLAUCOMA, 2020, 29 (12) :1147-1151
[30]   Adherence and Persistence with Glaucoma Therapy [J].
Schwartz, Gail R. ;
Quigley, Harry A. .
SURVEY OF OPHTHALMOLOGY, 2008, 53 :S57-S68