High-Throughput Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry Method Validation for the Estimation of Atorvastatin and Active Metabolites in Human Plasma

被引:0
|
作者
Agrawal, Nikhil [1 ]
Mittal, Amit [1 ,2 ,3 ]
机构
[1] Lovely Profess Univ, Sch Pharmaceut Sci, Dept Pharmaceut Chem, Phagwara, India
[2] Desh Bhagat Univ, Fac Pharmaceut Sci, Dept Pharmaceut Chem, Mandi Gobindgarh, India
[3] Lovely Profess Univ, Sch Pharmaceut Sci, Dept Pharmaceut Chem, Jalandhar Delhi GT Rd NH 44, Phagwara 144411, Punjab, India
关键词
atorvastatin; active metabolites; ultra high-performance liquid chromatography-liquid chromatography; mass spectrometry; bioanalytical; method validation (UPLC-MS; MS); PARA-HYDROXY ATORVASTATIN; LC-MS/MS; SIMULTANEOUS QUANTIFICATION; MS; QUANTITATION;
D O I
10.1089/adt.2022.113
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A highly selective, sensitive, rugged, and rapid ultra high-performance liquid chromatography-tandem mass spectrometry method (UPLC-MS/MS) is optimized and validated for reliable quantification of atorvastatin (ATR) and its active metabolites, 2-hydroxy atorvastatin (2-ATR) and 4-hydroxy atorvastatin (4-ATR) in human plasma using atorvastatin-D5 (ATR-D5), 2-hydroxy atorvastatin-D5 (2-ATR-D5), and 4-hydroxy atorvastatin-D5 (4-ATR-D5) as deuterium-labeled internal standards (ISTDs), respectively. Isocratic mode chromatographic separation was used with a reverse-phase C-18 Symmetry Shield (150 x 4.6 mm, 5.0 mu m) column and a mobile phase of acetonitrile:2 mM ammonium formate (pH-3.0) [65:35%v/v] at a flow rate of 0.7 mL/min. Electrospray ionization technique with positive ion mode polarity was applied to achieve the best signal intensity and stable response. Solid-phase extraction by direct elution method was applied to extract the drugs from the plasma sample. The calibration curve range was validated from a concentration range of 0.500-250 ng/mL for ATR and 2-ATR and 0.200-20 ng/mL for 4-ATR. The within-batch and between-batch precision and accuracy were found to be consistent and reproducible for all the analytes across the validation. Extraction recoveries were >80% for all analytes and ISTDs. All peaks of analytes and the respective ISTDs were eluted within 5.2 min. In this validated method, selective multivariate analytical approaches were utilized such as best fit linearity range for different strength formulations, preventive measures for in vivo and ex vivo autodegradation of metabolites, and shorter analysis time. This validated method can be useful for challenging quantification of ATR and its active metabolites for therapeutic drug monitoring and in high-throughput clinical study sample analysis.
引用
收藏
页码:110 / 125
页数:16
相关论文
共 50 条
  • [41] Validation of a simple, fast liquid chromatography-tandem mass spectrometry method for the simultaneous quantification of 40 antidepressant drugs or their metabolites in plasma
    Degreef, Maarten
    van Nuijs, Alexander L. N.
    Maudens, Kristof E.
    CLINICA CHIMICA ACTA, 2018, 485 : 243 - 257
  • [42] A high-performance liquid chromatography-tandem mass spectrometry method for the determination of artemether and dihydroartemisinin in human plasma
    Hilhorst, M. J.
    Hendriks, G.
    de Vries, R.
    Hillewaert, V.
    Verhaege, T.
    van de Merbelac, N. C.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 965 : 45 - 53
  • [43] Quantification of methylone and metabolites in rat and human plasma by liquid chromatography-tandem mass spectrometry
    Ellefsen, Kayla N.
    Concheiro, Marta
    Suzuki, Masaki
    Rice, Kenner C.
    Elmore, Joshua S.
    Baumann, Michael H.
    Huestis, Marilyn A.
    FORENSIC TOXICOLOGY, 2015, 33 (02) : 202 - 212
  • [44] Simultaneous quantitation of atorvastatin and its two active metabolites in human plasma by liquid chromatography/(–) electrospray tandem mass spectrometry
    Pankaj Partani
    S.Manaswita Verma
    Sanjay Gurule
    Arshad Khuroo
    Tausif Monif
    JournalofPharmaceuticalAnalysis, 2014, 4 (01) : 26 - 36
  • [45] Development and validation of a high-performance liquid chromatography-tandem mass spectrometry assay quantifying olaparib in human plasma
    Nijenhuis, C. M.
    Lucas, L.
    Rosing, H.
    Schellens, J. H. M.
    Beijnen, J. H.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 940 : 121 - 125
  • [46] Determination of antibiotics and their metabolites in milk by liquid chromatography-tandem mass spectrometry method
    Tasci, Fulya
    Canbay, Hale Secilmis
    Doganturk, Mahmut
    FOOD CONTROL, 2021, 127
  • [47] Quantification of sunitinib in human plasma by high-performance liquid chromatography-tandem mass spectrometry
    Minkin, Patton
    Zhao, Ming
    Chen, Zhaoyuan
    Ouwerkerk, Jan
    Gelderblom, Hans
    Baker, Sharyn D.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 874 (1-2): : 84 - 88
  • [48] Determination of repaglinide in human plasma by high-performance liquid chromatography-tandem mass spectrometry
    Zhang, Jie
    Gao, Feng
    Guan, Xin
    Sun, Yan-tong
    Gu, Jing-kai
    Fawcett, J. Paul
    ACTA PHARMACEUTICA SINICA B, 2011, 1 (01) : 40 - 45
  • [49] A simple and rapid ultra-high-performance liquid chromatography-tandem mass spectrometry method to determine plasma biotin in hemodialysis patients
    Yagi, Shigeaki
    Nishizawa, Manabu
    Ando, Itiro
    Oguma, Shiro
    Sato, Emiko
    Imai, Yutaka
    Fujiwara, Masako
    BIOMEDICAL CHROMATOGRAPHY, 2016, 30 (08) : 1285 - 1290
  • [50] Development of a new ultra-high-performance liquid chromatography-tandem mass spectrometry method for the determination of digoxin and digitoxin in plasma: Comparison with a clinical immunoassay
    Ballotari, Marco
    Tau, Francesco
    Tolle, Giulia
    Danese, Elisa
    Dorizzi, Romolo M.
    Tagliaro, Franco
    Gottardo, Rossella
    ELECTROPHORESIS, 2022, 43 (9-10) : 1019 - 1026